The Worcester FKT Series comprises high-efficiency condensing gas boilers designed for central heating and domestic hot water. This manual provides essential instructions for safe installation, commissioning, and initial setup. It is intended for qualified heating engineers only. Incorrect installation can lead to property damage, injury, or invalidate the warranty. Read all instructions before proceeding.
Installation must comply with local regulations (e.g., GB in the UK: Gas Safety (Installation and Use) Regulations, BS 6798, Building Regulations).
| Symbol | Meaning |
|---|---|
| WARNING! | Risk of personal injury or death. Immediate hazard present. |
| CAUTION! | Risk of damage to the appliance or property. |
| NOTICE | Important information for correct operation. |
WARNING! This appliance must be installed by a Gas Safe Registered engineer (UK) or equivalently qualified professional. Ensure gas supply is isolated before beginning work. Do not install in rooms containing a bath or shower unless a room-sealed flue is used.
Unpack and verify all components are present and undamaged.
Select a suitable location adhering to clearance distances for servicing and ventilation.
CAUTION! Do not install in frost-prone areas without protection. The boiler must be level when mounted.
WARNING! The boiler is heavy. Use appropriate lifting techniques or a second person.
Connect to the labelled ports on the underside of the boiler: Gas (G), Central Heating Flow (CH ➜), Central Heating Return (CH ➜), Cold Water Inlet (CW), Hot Water Outlet (HW).
NOTICE: Pipework must be supported independently of the boiler. Use copper or approved plastic pipe.
The boiler MUST be installed with the approved concentric room-sealed flue system.
| Requirement | Detail |
|---|---|
| Flue Terminal Position | Min. 300mm from an opening window, door, or air vent. Clear of obstructions. |
| Maximum Flue Length | As per model-specific tables (typically 10m equivalent length). |
| Condensate Pipe | 22mm OD pipe, insulated if external, fall of at least 2.5° towards drain. |
WARNING! Incorrect flue installation is extremely dangerous, risking carbon monoxide poisoning. Follow the separate flue installation guide precisely.
Gas: Connect to the boiler's 22mm male threaded connection using an approved gas hose or rigid pipe. Test for soundness after connection. The gas governor and meter must be sized appropriately for the boiler's input rate.
Electrical:
CAUTION! Electrical work must comply with IET Wiring Regulations (BS 7671). Ensure correct polarity and earth continuity.
For sealed systems only (combi models).
Front panel consists of: Digital display, Power/Reset button, Mode selector dial, Temperature adjustment buttons (+/-).
| Display Icon | Meaning |
|---|---|
| Radiator Symbol | Central Heating mode active. |
| Tap Symbol | Domestic Hot Water mode active. |
| Flame Symbol | Boiler is firing. |
| Wrench Symbol | Service mode or fault indicated. |
Use the mode dial to select: OFF, HOT WATER ONLY, HEATING ONLY, HOT WATER & HEATING. Temperature is set with the +/- buttons.
| Fault Code | Description | Action |
|---|---|---|
| EA | Ignition failure | Check gas supply, electrode, ignition leads. |
| F0 | Flow NTC sensor fault | Check sensor resistance/connection. |
| F1 | Return NTC sensor fault | Check sensor resistance/connection. |
| L2 | Low water pressure | Re-pressurise system to 1.0-1.5 bar. Check for leaks. |
| P1 | Flue/air pressure switch fault | Check flue for blockage, pressure switch tubing. |
Reset: For lockout faults, turn the boiler off at the spur for 30 seconds, then back on. If the fault persists, consult a qualified engineer.
Service & Support: For technical assistance, contact Worcester Bosch Technical Helpline or visit www.worcester-bosch.co.uk. Always quote the boiler's GC number and serial number.