The Vimar 46243.030CL is a sophisticated lighting control module designed for integration into modern smart home systems. It features relay-based control, compatibility with standard electrical wiring, support for automation protocols, manual override capability, LED status indication, and a compact design for easy installation in standard electrical boxes. Below are key sections for safety, features, installation, configuration, operation, and troubleshooting.
Key components: Relay module, Control terminals, Status LED, Manual override button, Communication bus connector.
| Feature | Description |
|---|---|
| Relay Output | Controls connected lighting load (e.g., up to 16A) |
| Control Terminals | For connection to switch inputs or sensors |
| Status LED | Indicates module power and operational state |
| Manual Override Button | Allows local manual control of the relay |
| Communication Bus Connector | For integration into home automation systems (e.g., KNX, proprietary bus) |
| Power Supply Terminals | For module auxiliary power (e.g., 24V DC) |
| Compact Design | Fits standard deep electrical boxes |
| DIN Rail Mountable | Optional mounting for panel installations |
| Safety Isolation | Galvanic isolation between bus and power circuit |
| Programmable Scenes | Supports lighting scenes via system programming |
Unpack and inspect contents. Ensure power is OFF at the circuit breaker.
WARNING! Installation must be performed by a qualified electrician in accordance with local regulations. Ensure all connections are secure and insulated.
Apply power; the status LED should illuminate.
CAUTION! Do not apply mains voltage to the low-voltage control or bus terminals. Verify parameters before finalizing.
Local control via manual button. System control via bus commands.
Manual Button: Press to toggle relay state. LED indicates status (e.g., steady on = relay energized, flashing = programming mode).
Programmable Parameters (via software): Relay type (latching/pulse), input logic (active high/low), reaction to short/long press, local/remote priority, timing functions (on delay, off delay, staircase function), scene membership.
Bus Connection: Use shielded twisted pair cable. Connect polarity correctly (A/B or +/-).
Tip: Label all bus cables and device addresses for easier maintenance and troubleshooting.
Supports various control modes based on configuration.
WARNING! Do not connect loads exceeding the specified rating. Ensure load type (resistive, inductive) is compatible.
Logic Functions: Can be programmed with AND/OR logic for multiple input conditions. Telegrams: Sends status feedback telegrams to the bus upon state change. Failure Reporting: Can indicate communication loss or fault conditions via LED pattern.
Disconnect power before any maintenance. Keep the module clean and free from dust. Ensure ventilation is not obstructed.
CAUTION! Do not use compressed air or liquids for cleaning. The module contains electronic components sensitive to static discharge.
This product complies with the essential requirements of the following EU Directives: Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and RoHS Directive 2011/65/EU. The CE marking indicates conformity. Copyright and trademarks are property of Vimar S.p.A. For technical support, configuration software, and documentation, visit www.vimar.com or contact your local Vimar representative.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Module not powering up (LED off) | No auxiliary power | Check 24V DC supply connections and voltage. Verify fuse. |
| Relay does not switch | Incorrect wiring / programming | Check load wiring. Verify relay parameters in configuration software. |
| No response to bus commands | Incorrect address / bus fault | Verify module address. Check bus cable continuity, polarity, and termination. |
| Manual button does not work | Button disabled via programming | Check parameter "Local Control Enable". |
| LED flashing rapidly | Communication error / programming mode | Check bus connection. If in programming mode, complete or cancel programming via tool. |
Reset: Factory reset is typically performed via configuration software. Hardware reset may require specific jumper settings (consult advanced manual).
Service: For warranty and service, contact the installer or Vimar support via www.vimar.com.