Vimar 46243.030CL Quick Manual

The Vimar 46243.030CL is a sophisticated lighting control module designed for integration into modern smart home systems. It features relay-based control, compatibility with standard electrical wiring, support for automation protocols, manual override capability, LED status indication, and a compact design for easy installation in standard electrical boxes. Below are key sections for safety, features, installation, configuration, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Configuration 4. Specifications 5. Controls and Settings 6. Connecting to Systems 7. Operation Modes 8. Advanced Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Relay module, Control terminals, Status LED, Manual override button, Communication bus connector.

FeatureDescription
Relay OutputControls connected lighting load (e.g., up to 16A)
Control TerminalsFor connection to switch inputs or sensors
Status LEDIndicates module power and operational state
Manual Override ButtonAllows local manual control of the relay
Communication Bus ConnectorFor integration into home automation systems (e.g., KNX, proprietary bus)
Power Supply TerminalsFor module auxiliary power (e.g., 24V DC)
Compact DesignFits standard deep electrical boxes
DIN Rail MountableOptional mounting for panel installations
Safety IsolationGalvanic isolation between bus and power circuit
Programmable ScenesSupports lighting scenes via system programming

Installation

Unpack and inspect contents. Ensure power is OFF at the circuit breaker.

  1. Mount the module: Secure in a suitable electrical box or on DIN rail.
  2. Connect load wiring: Connect the switched live output to the lighting circuit. Ensure correct cable gauge.
  3. Connect control inputs: Wire momentary or maintained switches to the input terminals.
  4. Connect bus cable: If using, connect the communication bus cable to the designated terminals.
  5. Connect auxiliary power: Supply the required low-voltage power to the module.

WARNING! Installation must be performed by a qualified electrician in accordance with local regulations. Ensure all connections are secure and insulated.

First-Time Configuration

Apply power; the status LED should illuminate.

  1. Address assignment: Use the system configuration tool (PC software or handheld) to set the module's unique bus address.
  2. Parameter programming: Configure relay behavior (toggle, momentary, dimming control), input types, and timing functions.
  3. Test operation: Use the connected switch or the manual button to toggle the relay and control the light.
  4. Integrate into scenes: Assign the module to lighting groups or scenes within the automation system.

CAUTION! Do not apply mains voltage to the low-voltage control or bus terminals. Verify parameters before finalizing.

Specifications

Controls and Settings

Local control via manual button. System control via bus commands.

Manual Button: Press to toggle relay state. LED indicates status (e.g., steady on = relay energized, flashing = programming mode).

Programmable Parameters (via software): Relay type (latching/pulse), input logic (active high/low), reaction to short/long press, local/remote priority, timing functions (on delay, off delay, staircase function), scene membership.

Connecting to Systems

Bus Connection: Use shielded twisted pair cable. Connect polarity correctly (A/B or +/-).

  1. Power down the entire system bus before connecting new devices.
  2. Connect the bus cable from the previous device or system controller to the module's IN terminals.
  3. Connect the bus cable from the module's OUT terminals to the next device, if daisy-chaining.
  4. Ensure bus termination is configured correctly at the line ends if required by the system.

Tip: Label all bus cables and device addresses for easier maintenance and troubleshooting.

Operation Modes

Supports various control modes based on configuration.

  1. Basic Switching: Toggle light on/off with each button press.
  2. Momentary Mode: Light is on only while button is held (configured via software).
  3. Dimming Control: If configured with a dimmer actuator, can control light level via long press or scene recall.
  4. Timed Operation: Staircase function - light turns on for a set period then automatically off.
  5. Scene Control: Recall predefined lighting scenes sent via the bus system.
  6. Central Control: Relay can be operated by central commands (All On, All Off, group commands).

WARNING! Do not connect loads exceeding the specified rating. Ensure load type (resistive, inductive) is compatible.

Advanced Features

Logic Functions: Can be programmed with AND/OR logic for multiple input conditions. Telegrams: Sends status feedback telegrams to the bus upon state change. Failure Reporting: Can indicate communication loss or fault conditions via LED pattern.

Care & Maintenance

Disconnect power before any maintenance. Keep the module clean and free from dust. Ensure ventilation is not obstructed.

CAUTION! Do not use compressed air or liquids for cleaning. The module contains electronic components sensitive to static discharge.

Regulatory Information

This product complies with the essential requirements of the following EU Directives: Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and RoHS Directive 2011/65/EU. The CE marking indicates conformity. Copyright and trademarks are property of Vimar S.p.A. For technical support, configuration software, and documentation, visit www.vimar.com or contact your local Vimar representative.

Troubleshooting

SymptomPossible CauseCorrective Action
Module not powering up (LED off)No auxiliary powerCheck 24V DC supply connections and voltage. Verify fuse.
Relay does not switchIncorrect wiring / programmingCheck load wiring. Verify relay parameters in configuration software.
No response to bus commandsIncorrect address / bus faultVerify module address. Check bus cable continuity, polarity, and termination.
Manual button does not workButton disabled via programmingCheck parameter "Local Control Enable".
LED flashing rapidlyCommunication error / programming modeCheck bus connection. If in programming mode, complete or cancel programming via tool.

Reset: Factory reset is typically performed via configuration software. Hardware reset may require specific jumper settings (consult advanced manual).

Service: For warranty and service, contact the installer or Vimar support via www.vimar.com.