Utepo UPSP200-2 Quick Installation Manual

The Utepo UPSP200-2 is a 200VA Uninterruptible Power Supply (UPS) designed to provide backup power and surge protection for connected devices. It features automatic voltage regulation (AVR), battery backup, surge protection, audible alarms, and USB connectivity for monitoring. Below are key sections for safety, unpacking, installation, operation, and troubleshooting.

1. Package Contents 2. Safety Precautions 3. Front Panel & Indicators 4. Rear Panel Connections 5. Installation Steps 6. Initial Setup & Operation 7. Specifications 8. Maintenance 9. Troubleshooting 10. Warranty & Support

Package Contents

Before installation, verify all components are present.

ItemDescription
UPSP200-2 UPS UnitMain uninterruptible power supply
Power CordFor connecting UPS to AC outlet
User ManualThis quick installation guide
USB CableFor connecting to computer (optional monitoring)
Warranty CardProduct warranty information

Safety Precautions

Read all safety instructions before installation and operation.

  1. Place UPS on a stable, dry surface away from heat sources and liquids.
  2. Ensure proper ventilation; do not block vents.
  3. Connect only to a grounded AC outlet (120V, 60Hz).
  4. Do not open the UPS casing; no user-serviceable parts inside.
  5. Do not connect laser printers, copiers, or other high-power devices to battery backup outlets.

WARNING! Risk of electric shock. Disconnect from power before cleaning or servicing. Battery replacement must be performed by qualified personnel.

Front Panel & Indicators

The front panel provides status LEDs and controls.

Indicator/ButtonFunction
POWER ButtonTurns UPS on/off
AC/Line LED (Green)Lit when connected to AC power
Battery LED (Yellow)Lit during battery operation; flashes when battery low
Overload/Fault LED (Red)Lit when overload or fault condition detected
Alarm Silence ButtonPress to mute audible alarm temporarily

Rear Panel Connections

Connect devices to appropriate outlets.

Tip: Connect critical devices (computer, modem, router) to battery backup outlets.

Installation Steps

Follow these steps for proper installation.

  1. Unpack and inspect UPS for damage.
  2. Place UPS near equipment to be protected, ensuring adequate ventilation.
  3. Connect the UPS power cord to the rear input plug, then plug into a grounded wall outlet.
  4. Connect your devices (computer, monitor, etc.) to the appropriate UPS outlets.
  5. For monitoring, connect the USB cable from the UPS to your computer (optional).
  6. Press the POWER button on the front panel to turn on the UPS.

CAUTION! Do not exceed the maximum load capacity (200VA/120W).

Initial Setup & Operation

After installation, allow battery to charge fully.

  1. With UPS connected to AC power and turned on, the battery will charge automatically (requires 8 hours for full charge from empty).
  2. Observe front panel LEDs: AC/Line LED should be solid green.
  3. Test battery operation by unplugging the UPS from the wall outlet. Connected devices should remain powered, and the Battery LED will illuminate.
  4. Restore AC power; the UPS will return to normal operation and resume charging.
  5. Install power management software from the manufacturer's website (using USB connection) for advanced features like automatic shutdown.

Note: The UPS emits audible alarms during battery operation and low battery conditions.

Specifications

Maintenance

Proper maintenance ensures optimal performance and longevity.

  1. Keep UPS in a cool, dry environment (operating temperature 32°F to 104°F / 0°C to 40°C).
  2. Periodically test battery by performing a simulated power outage test (unplug from wall).
  3. If the battery LED flashes rapidly or the unit fails a test, the battery may need replacement.
  4. Clean exterior with a dry cloth; do not use liquids or aerosols.
  5. Do not store the UPS in a discharged state for extended periods.

WARNING! Battery replacement must be done by qualified service personnel. Do not disassemble.

Troubleshooting

SymptomPossible CauseCorrective Action
UPS does not turn onNo AC power / Faulty outletCheck wall outlet; ensure power cord is securely connected at both ends.
Continuous beepingBattery low or overloadReduce connected load; recharge UPS by leaving plugged into AC power.
Overload/Fault LED litConnected load exceeds capacityDisconnect some devices; press circuit breaker button on rear panel.
Short backup timeBattery old or not fully chargedAllow 8+ hours for full charge; replace battery if performance is poor after charging.
USB not recognizedDriver/software issueInstall power management software from manufacturer's website; try different USB port.

Reset: Turn UPS off, disconnect from AC power and all devices for 5 minutes, then reconnect and power on.

Warranty & Support

Utepo UPSP200-2 is covered by a limited warranty. For technical support or warranty service:

Retain your sales receipt for warranty validation. This product complies with FCC Part 15 Class B limits.

Utepo UPSP200-2 Quick Installation Manual © - All Rights Reserved 2025