Unique UGP-100WSP Owner's Manual

The Unique UGP-100WSP is a 100-watt portable solar power generator designed for outdoor, emergency, and off-grid use. It features a high-capacity lithium battery, multiple AC/DC/USB outputs, pure sine wave inverter, MPPT solar charge controller, LCD display showing input/output status, overload protection, and a rugged, weather-resistant casing. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Solar Charging Operation 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Lithium-ion Battery Pack, Pure Sine Wave Inverter, MPPT Charge Controller, LCD Status Panel, Multiple Output Ports, Carrying Handle.

FeatureDescription
AC OutputPure sine wave, 100W continuous (200W surge)
DC Output Ports12V/10A car socket and 5.5x2.1mm barrel jack
USB OutputsTwo USB-A (5V/2.4A) and one USB-C (PD 18W)
Solar InputDC 12-24V, supports up to 120W solar panel
Car Charger Input12V/24V vehicle adapter input
Wall Charger InputAC 100-240V, 50/60Hz
LCD DisplayShows battery level, input/output power, warnings
Overload ProtectionAutomatic shutdown on overload; resettable
Cooling FanTemperature-controlled for quiet operation
Carrying HandleIntegrated for easy portability

Installation

Unpack and inspect contents. Place on stable, dry surface.

  1. Initial Charge: Connect to wall charger using provided cable until LCD shows 100%.
  2. Positioning: Ensure unit is in a well-ventilated area, away from direct heat sources or water.
  3. Solar Panel Setup: Connect compatible solar panel to the SOLAR INPUT port using MC4 to XT60 cable (sold separately).
  4. Device Connection: Plug your devices into the appropriate output ports.

WARNING! Unit contains a heavy battery; lift with care using the handle. Do not block ventilation ports.

First-Time Setup

Power on unit; observe LCD display.

  1. Initial Power-Up: Press and hold the POWER button for 2 seconds. The LCD will illuminate.
  2. Battery Calibration: For accurate readings, perform a full charge/discharge cycle initially.
  3. Output Selection: Press the OUTPUT MODE button to cycle between AC, DC, and USB outputs (some models).
  4. Configure Settings: Use the SETTINGS button (if available) to set auto-shutdown timer or brightness.

CAUTION! Charge fully before first use. Use only provided or recommended chargers.

Specifications

Controls and Settings

Access functions via front panel buttons and LCD menu.

Front Panel: POWER Button, OUTPUT MODE Button, LCD Display, USB/DC/AC Output Ports, Input Ports.

LCD Menu Navigation: Short press SETTINGS to enter menu; use +/- buttons to adjust values.

Settings: Auto Power Off (2/4/6 hrs), LCD Brightness, Buzzer On/Off, Battery Save Mode. Status Display: Real-time input power, output power, battery percentage, estimated runtime. Protection Indicators: Icons for overload, high temperature, low battery.

Connecting Devices

Match device power requirements to appropriate output.

  1. Check Device Rating: Ensure device wattage/amperage is within unit's limits.
  2. Connect to AC: Plug devices into the AC outlet. Press AC button to enable.
  3. Connect to DC: Use 12V car port for car appliances or DC barrel jack for compatible devices.
  4. Connect to USB: Plug phones/tablets into USB-A or USB-C ports. USB-C supports fast charging.
  5. Select Input: For charging, connect solar panel, car charger, or wall charger to corresponding input port.

Tip: Start with the highest power device first to manage load. Do not exceed 100W total AC output.

Solar Charging Operation

Utilizes MPPT technology for efficient solar charging.

  1. Panel Compatibility: Use a 12V or 24V solar panel up to 120W.
  2. Connection: Connect panel to SOLAR INPUT port. LCD will show solar icon and input watts.
  3. Optimal Positioning: Angle panel directly towards the sun for maximum power.
  4. Charging Time: Approx. 4-6 hours from 0% with a 100W panel in ideal sunlight.
  5. Monitoring: Watch input power on LCD. It will vary with sunlight intensity.

WARNING! Do not connect a solar panel exceeding 120W or 24V. Disconnect in storms or extreme weather.

Safety Features

Built-in protections for safe operation.

Care & Maintenance

Unplug all devices before cleaning. Store in a cool, dry place.

  1. Cleaning: Use a dry, soft cloth. Do not use liquids or abrasive cleaners.
  2. Battery Health: For long-term storage (>3 months), charge to 50-60% and store in a cool place. Recharge every 3 months.
  3. Ventilation: Keep vents clear of dust and debris. Use compressed air to gently clean if necessary.
  4. Inspection: Periodically check cables and ports for damage.

CAUTION! Do not disassemble the unit. No user-serviceable parts inside. Risk of electric shock or fire.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits. CE, RoHS compliant. Contains lithium-ion battery; follow local regulations for disposal/recycling. Copyright © 2025 Unique Power Solutions. For support, visit www.uniquepower.com/support or contact 1-800-555-UGP1 (8471).

Troubleshooting

SymptomPossible CauseCorrective Action
Unit will not power onBattery depleted, faulty buttonConnect to charger for 30 mins. Press and hold power button firmly for 3 seconds.
No output from AC portOverload, inverter off, LVD triggeredReduce connected load. Ensure AC button is pressed. Recharge battery.
Solar panel not chargingInsufficient sun, wrong connection, panel faultCheck sunlight and panel alignment. Verify cable connection. Test panel voltage.
LCD display is blankUnit in sleep mode, display faultPress any button to wake. Connect to charger. If persists, contact support.
Fan runs continuouslyHigh ambient temperature, high loadMove unit to cooler area. Reduce output load. This is normal under heavy use.
Battery drains quicklyOld battery, high parasitic load, cold tempsReduce standby devices. Store and use within recommended temperature range.

Reset: Disconnect all inputs/outputs. Press and hold POWER for 10 seconds. Reconnect charger.

Service: 1-800-555-UGP1 (8471); www.uniquepower.com/support