Sygonix 3344071 Operating Instructions Manual

The Sygonix 3344071 is a professional-grade electronic device designed for industrial measurement and control applications. It features high-precision sensors, a robust housing (IP65 rated), configurable analog/digital outputs, a backlit LCD display, programmable setpoints, and communication via RS-485 Modbus RTU. Powered by 24V DC, it is suitable for monitoring pressure, temperature, or flow in demanding environments. Below are key sections covering safety, features, installation, configuration, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Technical Specifications 5. Controls and Interface 6. Connecting to Systems 7. Configuration & Programming 8. Operational Modes 9. Maintenance & Calibration 10. Regulatory & Compliance 11. Troubleshooting

Features at a Glance

Key components: High-precision sensor unit, IP65 aluminum enclosure, LCD display with backlight, 4-button keypad, terminal blocks for power and I/O, and communication port.

FeatureDescription
Measurement RangeConfigurable for pressure (0-10 bar), temperature (-40°C to +125°C), or flow (0-100 l/min)
Outputs1x 4-20mA analog, 2x programmable relay outputs (SPDT, 5A)
Display4-digit LCD with bargraph and unit indicators
CommunicationRS-485, Modbus RTU protocol
Power Supply24V DC ±10% (standard)
Enclosure RatingIP65 (dust-tight and protected against water jets)
Keypad ButtonsMENU, UP, DOWN, ENTER
ProgrammingConfigurable setpoints, hysteresis, output functions, and communication address
DiagnosticsSelf-test, error codes on display
MountingPanel mount (DIN rail adapter optional)

Installation

Unpack and verify contents. Ensure the installation environment is clean, dry, and within specified temperature limits.

  1. Mounting: Secure the device to a panel or DIN rail using the provided brackets. Ensure adequate space for wiring and ventilation.
  2. Electrical Connections: Remove the terminal cover. Connect power (24V DC) to terminals +V and GND. Connect analog output and relay outputs to respective terminals as per wiring diagram.
  3. Sensor Connection: Connect the process sensor (e.g., pressure transducer) to the dedicated sensor input terminals.
  4. Communication Wiring: For RS-485, connect A (+), B (-), and GND terminals to the network bus, observing polarity and termination requirements.

WARNING! Disconnect power before making any electrical connections. Ensure wiring complies with local electrical codes. The device contains electrostatic-sensitive components; handle with appropriate precautions.

First-Time Setup

Apply power. The device performs a self-test (all display segments illuminate briefly).

  1. Select Measurement Parameter: Press MENU, navigate to "PArA" (Parameter), use UP/DOWN to select Pressure (PrES), Temperature (tEMP), or Flow (FLo). Press ENTER to confirm.
  2. Set Engineering Units: In the "Unit" menu, select bar, °C, l/min, etc.
  3. Configure Outputs: Navigate to "oUt1" (Analog Output). Set the 4mA and 20mA values corresponding to the measurement range.
  4. Set Relay Setpoints: For relays R1 and R2, define the activation value (e.g., 5.0 bar) and hysteresis (e.g., 0.2 bar).
  5. Save Configuration: Exit the menu; changes are saved automatically.

CAUTION! Incorrect parameter settings may lead to improper system operation. Verify settings before placing into service.

Technical Specifications

Controls and Interface

Front Panel: 4-digit LCD display, 4 tactile buttons (MENU, UP, DOWN, ENTER), LED status indicator.

Display Symbols: 'A' (Analog output active), 'R1'/'R2' (Relay energized), 'Err' (Fault).

Menu Structure: Access by pressing MENU. Navigate with UP/DOWN, enter submenus with ENTER.
- PArA: Select measured parameter and unit.
- oUt1: Configure 4-20mA output scaling.
- rEL1, rEL2: Set relay trigger points and hysteresis.
- CoMM: Set Modbus address (1-247) and baud rate.
- diAG: View min/max values, reset to defaults.

Default Settings: Parameter: Pressure (PrES), Unit: bar, Address: 1, Baud: 9600.

Connecting to Systems

To PLC/SCADA via Analog: Connect the 4-20mA output to the analog input module of your controller.

To PLC/SCADA via Digital: Connect relay contacts to digital inputs for alarm/control functions.

To Network via Modbus RTU: Connect RS-485 terminals to a Modbus master (PLC, PC with adapter). Ensure unique addresses and proper termination (120 Ω resistor at bus ends).

  1. Power off all devices on the bus before connecting.
  2. Use shielded twisted-pair cable for RS-485 connections. Connect shield to GND at one point only.
  3. After connection, configure the master software with the correct device address and register map (see separate communication manual).

Tip: For long cable runs (>1000m), use repeaters and verify signal integrity.

Configuration & Programming

All settings are made via the front keypad. The device stores configuration in non-volatile memory.

  1. Enter Programming Mode: Press and hold MENU for 3 seconds. The display shows the top-level menu.
  2. Navigate: Use UP/DOWN to scroll through menu items (PArA, oUt1, etc.). Press ENTER to select.
  3. Adjust Values: Within a submenu, use UP/DOWN to change the value. Press ENTER to confirm and move to the next setting, or press MENU to cancel and go back.
  4. Calibration (Advanced): Access the "CAL" menu (requires password 1234). Here you can perform a 2-point calibration using known reference values. This should only be done by qualified personnel with calibrated reference instruments.
  5. Exit: Press MENU repeatedly to return to the normal measurement display.

WARNING! Unauthorized calibration may void warranty and affect measurement accuracy. Record original settings before making changes.

Operational Modes

Normal Measurement Mode: Displays current measured value. The bargraph provides a visual trend. Relay and analog outputs are active according to configuration.

Peak Hold Mode: Can be enabled in the menu. The display shows the maximum value recorded since the last reset.

Valley Hold Mode: Can be enabled in the menu. The display shows the minimum value recorded since the last reset.

Display Off Mode: The backlight can be set to turn off after a period of inactivity to save power.

Maintenance & Calibration

Routine Maintenance: Periodically inspect the device for physical damage, clean the display with a soft, dry cloth, and check terminal tightness (power off).

Recommended Calibration Interval: 12 months, or as required by your quality system.

Calibration Procedure:
1. Connect the device to a stable power supply and a precision reference standard.
2. Access the CAL menu (password 1234).
3. Apply a zero-point reference (e.g., atmospheric pressure for gauge pressure). Select "CAL0" and confirm.
4. Apply a span-point reference (e.g., 10.00 bar). Select "CAL1" and confirm.
5. Exit the menu. The device is now calibrated.

CAUTION! Perform calibration in a controlled environment. Use only appropriate, calibrated reference equipment. Incorrect calibration can lead to significant measurement errors.

Regulatory & Compliance

EMC Directive 2014/30/EU: Complies with emission and immunity standards for industrial environments.

Low Voltage Directive 2014/35/EU: Complies with safety requirements.

RoHS Directive 2011/65/EU: Complies with restrictions on hazardous substances.

FCC Part 15: Class A digital device. This equipment may cause radio interference in residential areas; the user may be required to take corrective measures.

Manufacturer: Sygonix GmbH. Copyright © 2023. All rights reserved. Sygonix is a registered trademark.

Support: For technical support, calibration certificates, or spare parts, visit www.sygonix.com or contact your local distributor.

Troubleshooting

SymptomPossible CauseCorrective Action
Display is blankNo power, incorrect voltageCheck power connections and voltage (24V DC ±10%). Ensure polarity is correct.
Display shows "Err1"Sensor input open circuit or short circuitCheck sensor wiring and connections. Verify sensor is functional.
Display shows "Err2"Internal memory errorCycle power. If persistent, perform a factory reset (see below). Contact support if error remains.
Analog output incorrectWrong scaling, load impedance too highCheck output configuration (oUt1 menu). Ensure load ≤ 500 Ω.
Relay does not switchSetpoint misconfigured, faulty loadVerify relay settings (rEL1/rEL2). Check the connected load does not exceed relay ratings (5A).
No Modbus communicationWrong address, baud rate, wiring faultVerify device address and baud rate in CoMM menu. Check RS-485 wiring (A, B, GND) and termination.
Unstable readingElectrical noise, process instabilityEnsure sensor cable is shielded and away from power lines. Check for air bubbles or pulsations in fluid systems.

Factory Reset: With power off, press and hold UP and DOWN buttons. Apply power while holding buttons for 5 seconds. Release. All settings will revert to defaults (Address=1, Parameter=Pressure).

Service: Do not attempt to repair the device yourself. For service, contact Sygonix support at +49 (0)XXX XXXX XXX or [email protected]. Provide the model number (3344071) and serial number.