Suaoki 60W User Manual

The Suaoki 60W is a portable power station featuring a 60W AC pure sine wave inverter, multiple output ports (AC, DC, USB), a high-capacity lithium battery, LCD display for status monitoring, built-in safety protections (overload, short circuit, over-temperature), and compact design for outdoor, emergency, and mobile use. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Charging the Power Station 8. Safety Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Lithium-ion battery pack, AC pure sine wave inverter, LCD display, multiple output ports, charging input, cooling fan.

FeatureDescription
AC Output60W pure sine wave, 110V AC outlet
DC Output12V/10A car port for DC devices
USB OutputsDual USB ports (5V/2.4A each) for phones/tablets
LCD DisplayShows battery level, input/output wattage, warnings
Charging InputDC input for recharging via wall adapter or car charger
Battery CapacityHigh-capacity lithium battery (specified in mAh/Wh)
Power ButtonTurns AC/DC/USB outputs on/off
Cooling FanAutomatic temperature-controlled fan for heat dissipation
LED FlashlightBuilt-in emergency light with SOS mode
Safety ProtectionsOverload, short circuit, over-voltage, over-temperature

Installation

Unpack and inspect contents. Place on stable, dry surface away from heat and moisture.

  1. Initial Charge: Fully charge the power station before first use using provided adapter.
  2. Positioning: Ensure ventilation openings are unobstructed.
  3. Environment: Use in dry, indoor conditions or sheltered outdoor areas.
  4. Accessories: Connect provided cables as needed for charging or output.

WARNING! Do not expose to water, rain, or extreme temperatures. Keep away from flammable materials.

First-Time Setup

Power on the unit; monitor LCD display.

  1. Charge Fully: Connect to AC wall outlet using provided charger until LCD shows 100%.
  2. Power On: Press and hold Power button to activate outputs.
  3. Connect Device: Plug device into appropriate output port (AC, DC, USB).
  4. Monitor: Check LCD for battery level and output status.

CAUTION! Use only provided or manufacturer-approved charging accessories.

Specifications

Controls and Settings

Front Panel: Power Button, LCD Display, Output Ports, Flashlight Button.

Power Button: Press once to turn on DC/USB outputs; press again for AC output; hold to turn all outputs off.

Flashlight: Press once for steady light; press again for SOS strobe; press third time to turn off.

LCD Indicators: Battery percentage, Input/Output wattage, Warning icons (overload, high temperature). No user-adjustable settings; operation is automatic based on connected load.

Connecting Devices

AC Outlet: For devices ≤60W (e.g., laptops, small fans). DC Car Port: For 12V devices (e.g., car vacuum, air pump). USB Ports: For phones, tablets, lights.

  1. Check device power requirement (Watts or Amps) does not exceed port limit.
  2. Plug device cable firmly into correct port.
  3. Press Power button to activate the corresponding output (AC requires second press).
  4. Monitor LCD for load indication; disconnect if overload warning appears.

Tip: Start with the device turned off, then turn device on after connecting.

Charging the Power Station

Supports AC wall charging and 12V car charging.

  1. AC Charging: Connect provided wall adapter to DC Input port and wall outlet. LCD will show charging animation and battery percentage increasing.
  2. Car Charging: Connect provided car charger cable to DC Input port and vehicle's 12V accessory socket (cigarette lighter).
  3. Charging Time: Approximately [Insert] hours from empty to full.
  4. Completion: LCD shows 100% and charging icon stops. Disconnect charger.

WARNING! Use only provided or Suaoki-approved chargers. Do not charge near heat sources or in direct sunlight.

Safety Features

Automatic Protections: Unit will shut off output and display warning icon if overload, short circuit, over-temperature, or low battery occurs. Reset by disconnecting all devices and turning unit off/on. Low Battery Alarm: Unit beeps and flashes low battery icon when battery falls below 10%. Shuts down automatically shortly after to protect battery.

Care & Cleaning

Turn off and disconnect all devices before cleaning. Use dry, soft cloth to wipe exterior. Do not use liquids, solvents, or abrasive cleaners.

CAUTION! Do not open casing. No user-serviceable parts inside. Store in cool, dry place when not in use for extended periods.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © [Year] Suaoki; trademarks belong to Suaoki. Contains lithium-ion battery; follow local regulations for disposal/recycling. For support, visit www.suaoki.com or contact customer service.

Troubleshooting

SymptomPossible CauseCorrective Action
No power outputBattery depleted, unit offRecharge battery; press and hold Power button to turn on.
Device not workingOverload, wrong portCheck device power rating; connect to appropriate port; reduce load.
LCD shows warning iconOverload, high temperatureDisconnect all devices; let unit cool; restart in cooler environment.
Not chargingFaulty charger/cable, input port issueUse provided charger/cable; ensure secure connection; try different outlet.
Rapid battery drainHigh load, old batteryDisconnect high-wattage devices; battery may need replacement after long use.

Reset: Turn unit off, disconnect all devices and charger, wait 1 minute, then turn on.

Service: Do not disassemble. Contact Suaoki support for service inquiries.