Steren LAM-073 Instruction Manual

The Steren LAM-073 is a versatile LED light module designed for various lighting applications, featuring energy-efficient LED technology, multiple mounting options, adjustable brightness, and a durable construction. It operates on a standard voltage range and includes safety features for reliable performance. Below are key sections covering safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Power 7. Operation Modes 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: LED array, power input terminal, mounting brackets, control interface, thermal management system.

FeatureDescription
LED ArrayHigh-efficiency LEDs providing bright, uniform illumination
Power Input TerminalFor secure electrical connection
Mounting BracketsMultiple mounting options for flexible installation
Control InterfaceButtons or remote for adjusting brightness and modes
Thermal ManagementHeat sink for optimal LED performance and longevity
Dimmer CompatibilityWorks with standard dimmers (if applicable)
ON/OFF SwitchManual power control
Brightness AdjustmentVariable light output settings
Indicator LightShows operational status
Protective HousingDust and moisture resistant design

Installation

Unpack and inspect all components. Ensure mounting surface is clean and stable.

  1. Mount the module: Use provided brackets to secure to ceiling, wall, or surface.
  2. Connect power: Turn off power at circuit breaker; connect wires to terminal block.
  3. Secure connections: Ensure all electrical connections are tight and insulated.
  4. Restore power and test.

WARNING! Electrical shock hazard. Always disconnect power before installation. Use appropriate safety gear.

First-Time Setup

After installation, configure basic settings for optimal use.

  1. Power on: Switch ON/OFF to activate; indicator light should illuminate.
  2. Adjust brightness: Use control interface to set desired light level.
  3. Test modes: Cycle through available lighting modes if applicable.
  4. Mounting check: Ensure module is securely fastened and properly aligned.

CAUTION! Do not exceed maximum load rating. Ensure adequate ventilation around heat sink.

Specifications

Controls and Settings

Control via onboard buttons or optional remote. Front Panel: ON/OFF, BRIGHTNESS +/-, MODE.

Remote: POWER, BRIGHTNESS UP/DOWN, MODE SELECTION, TIMER SET.

Brightness: Adjust from minimum to maximum. Modes: Select preset lighting scenes (DAYLIGHT, WARM, COOL). Timer: Set auto-off duration (1-4 hours). Install: Voltage selection (auto-sensing), reset to factory defaults.

Connecting to Power

Connect to standard AC power supply using terminal block.

  1. Ensure power is off at breaker.
  2. Strip wire ends and connect to L (Live), N (Neutral), and G (Ground) terminals.
  3. Tighten screws securely; ensure no loose strands.
  4. Restore power and verify operation.

Tip: Use wire nuts or connectors for additional safety. Follow local electrical codes.

Operation Modes

Supports multiple lighting modes and adjustable brightness.

  1. Turn on: Press POWER or ON/OFF switch.
  2. Adjust brightness: Use +/- buttons to increase/decrease light output.
  3. Select mode: Press MODE to cycle through DAYLIGHT, WARM, COOL.
  4. Set timer: Hold TIMER button, then press to select duration (1-4 hours).
  5. Turn off: Press POWER or switch to OFF; timer will auto-off if set.

WARNING! Do not operate in wet conditions unless rated for damp locations. Keep away from flammable materials.

Safety Features

Over-temperature protection: Automatically reduces brightness if overheating. Short-circuit protection: Internal fuse prevents damage. Insulated housing: Protects against electrical shock.

Care & Maintenance

Disconnect power before cleaning. Wipe with dry, soft cloth; avoid abrasive cleaners.

CAUTION! Do not immerse in water. Do not use solvents or harsh chemicals.

Regulatory Information

Complies with relevant safety and EMC standards. CE marking indicates conformity with European directives. RoHS compliant: Contains no restricted hazardous substances. Copyright © Steren; trademarks owned by Steren Electronics International. For support, visit www.steren.com or contact customer service at 1-800-123-4567.

Troubleshooting

SymptomPossible CauseCorrective Action
Light does not turn onPower supply/connectionsCheck circuit breaker; verify wiring connections; ensure switch is ON.
Dim or flickering lightVoltage fluctuation/dimmerCheck input voltage; ensure compatible dimmer is used.
OverheatingVentilation blockageEnsure adequate airflow; clean heat sink; reduce ambient temperature.
Remote not workingBatteries/obstructionsReplace remote batteries; ensure line of sight to sensor.
Unusual noiseLoose componentsTurn off power; check for loose screws or parts; secure mounting.

Reset: Hold MODE and BRIGHTNESS - for 5 seconds to restore factory settings.

Service: 1-800-123-4567; www.steren.com

Steren LAM-073 Instruction Manual © - All Rights Reserved 2025