Steinbach speedsolar Sun 00-49120 Manual

The Steinbach speedsolar Sun 00-49120 is a high-efficiency solar water heating system designed for residential use. It features a solar collector, storage tank, pump station, controller, and mounting hardware. The system is engineered to reduce energy costs by harnessing solar energy to provide hot water. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Components 7. Operation 8. Maintenance 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Solar Collector, Storage Tank, Pump Station, Controller, Mounting Hardware, Temperature Sensors, Expansion Vessel.

FeatureDescription
Solar CollectorHigh-absorption flat plate collector for efficient heat capture
Storage TankInsulated tank with heat exchanger for hot water storage
Pump StationCirculates heat transfer fluid between collector and tank
ControllerElectronic control unit with display for system monitoring and settings
Mounting HardwareRoof or ground mounting brackets and rails
Temperature SensorsMonitors collector and tank temperatures
Expansion VesselCompensates for fluid expansion in the closed loop
Safety ValvePressure relief valve for system protection
Frost ProtectionIntegrated feature to prevent freezing in cold climates
Overheat ProtectionPrevents excessive temperatures in the system

Installation

Unpack and inspect all components. Installation must be performed by a qualified technician.

  1. Mount the solar collector: Install on a south-facing roof or suitable ground location using provided hardware.
  2. Position the storage tank: Place in a dry, indoor location near existing water heater connections.
  3. Install the pump station: Mount near the tank, ensuring proper orientation.
  4. Connect piping: Use insulated pipes for collector loop and domestic water connections.
  5. Electrical connections: Connect controller and pump to power supply as per wiring diagram.
  6. Fill and pressurize system: Fill heat transfer fluid loop and check for leaks.

WARNING! Roof work involves fall risk; use proper safety equipment. Ensure all connections are pressure-tight.

First-Time Setup

Power on the controller; follow initialization procedure.

  1. System initialization: Controller will perform self-test and detect sensors.
  2. Set language: In SETUP menu, select preferred language (default: ENGLISH).
  3. Configure parameters: Set pump differential temperatures, frost protection, and overheat limits.
  4. Test operation: Verify pump activation when collector is hotter than tank by set differential.
  5. Check hot water output: Allow system to run and verify hot water at taps.

CAUTION! Do not bypass safety devices. Ensure system is properly grounded.

Specifications

Controls and Settings

Access settings via controller buttons and display.

Controller Display: Shows collector temperature (T1), tank temperature (T2), pump status, and error codes.

Buttons: MENU, UP, DOWN, ENTER, ESC.

Settings Menu: Differential ON (default 6°C), Differential OFF (default 3°C), Frost Protection set point, Overheat limit, Pump run time, Language, Time/Date. Status Indicators: Pump On LED, Error LED, Solar Gain indicator.

Connecting Components

Follow piping and wiring diagrams provided in installation manual.

  1. Collector loop: Connect collector inlet/outlet to pump station with insulated copper pipes.
  2. Storage tank: Connect heat exchanger ports to pump station.
  3. Domestic water: Connect cold water inlet and hot water outlet to tank.
  4. Sensors: Plug collector and tank sensors into controller.
  5. Power: Connect controller to mains power and pump to controller output.

Tip: Use thread sealant on all threaded connections. Pressure test before filling.

Operation

System operates automatically once configured.

  1. Normal operation: Controller compares temperatures. Pump runs when T1 > T2 by differential ON setting.
  2. Pump stops when temperature difference falls below differential OFF setting.
  3. Frost protection: Pump runs if collector temperature approaches freezing point.
  4. Overheat protection: Pump runs or system dumps heat if tank temperature exceeds safe limit.
  5. Monitoring: Check controller display for temperatures and status.

WARNING! Do not touch collector or pipes during operation; they can be extremely hot.

Maintenance

Annual maintenance recommended by a qualified technician.

Care & Cleaning

Collector surface: Clean with water and soft cloth; avoid abrasive materials. Storage tank: Wipe exterior with damp cloth. Keep area around system clear of debris.

CAUTION! Do not use high-pressure water on collector. Do not walk on collector.

Regulatory Information

Complies with EU directives for pressure equipment and electromagnetic compatibility. Manufactured under ISO 9001 quality standards. Copyright © Steinbach GmbH. All trademarks are property of their respective owners. For technical support, visit www.steinbach-solar.com or contact +49 (0) 1234 567890.

Troubleshooting

SymptomPossible CauseCorrective Action
No hot waterPump not running, low sunCheck pump power and fuse; verify sun on collector; check controller settings.
Pump runs continuouslyStuck relay, sensor faultCheck sensor readings; reset controller; inspect relay.
Low system pressureLeak, fluid lossInspect for leaks; top up heat transfer fluid.
Error code on displaySensor failure, overtempRefer to error code list in manual; check sensor connections.
Collector glass crackedHail impact, thermal stressReplace collector glazing; contact service.

Reset: Press RESET button on controller (if available) or power cycle.

Service: +49 (0) 1234 567890; www.steinbach-solar.com