The Solar PV LOGIC STP005 is a 5kW single-phase grid-tied solar inverter designed for residential photovoltaic systems. It features MPPT technology for optimal energy harvest, a wide input voltage range, IP65-rated outdoor protection, integrated DC and AC disconnect switches, Wi-Fi monitoring capability via a dongle, a user-friendly LCD display, and compliance with relevant grid-connection standards. Below are key sections for safety, features, installation, commissioning, operation, monitoring, maintenance, and troubleshooting.
Key components: Aluminum alloy casing, LCD interface, DC switch, AC switch, Wi-Fi communication port, PV input terminals, AC output terminals, grounding point.
| Feature | Description |
|---|---|
| MPPT Technology | Maximizes energy harvest from solar panels under varying conditions |
| Wide PV Input Range | Operates efficiently with a broad range of string voltages |
| IP65 Protection | Suitable for outdoor installation, resistant to dust and water jets |
| Integrated Disconnect Switches | Built-in DC and AC isolators for safe maintenance |
| Wi-Fi Monitoring | Real-time data logging and remote monitoring via smartphone app |
| LCD Display | Shows operational status, power output, energy yield, and error codes |
| Grid Compliance | Meets local grid standards for voltage, frequency, and anti-islanding |
| Night-time Consumption | Low standby power consumption when not generating |
Unpack and inspect contents. Ensure installation site is suitable.
WARNING! Installation must be performed by a qualified electrician in accordance with all local electrical codes. Disconnect all power sources before working on the system.
After installation, power on the system in sequence.
CAUTION! Do not attempt to open the inverter casing. No user-serviceable parts inside.
The front panel features an LCD screen and status LEDs.
LCD Display Information: - Real-time AC Power (kW) - Daily Energy Yield (kWh) - Total Energy Yield (MWh) - PV Input Voltage & Current - Grid Voltage & Frequency - Inverter Temperature - Operational Status (Running, Fault, Standby) - Error Codes (if any)
Status LEDs: - POWER (Green): Steady = AC power present. - RUN (Green): Blinking = Inverter is feeding power to the grid. - FAULT (Red): Lit = A fault has been detected. Check the LCD for error code.
Buttons: (Below display) - ENTER/ESC: Navigate menus and confirm selections. - UP/DOWN: Scroll through display pages or change parameter values.
The inverter automatically synchronizes with the grid. For monitoring, use the Wi-Fi dongle.
Tip: Ensure your Wi-Fi signal is strong at the inverter's location for reliable monitoring.
The inverter operates automatically based on sunlight and grid conditions.
Common Alerts via App/Display: High temperature warning, low insulation resistance, grid fault, MPPT error.
WARNING! If the FAULT LED is continuously lit, investigate the cause promptly. Do not ignore persistent error codes.
Regular visual inspection is recommended. The inverter requires minimal maintenance.
CAUTION! Always turn OFF both the AC and DC switches and ensure the inverter is completely de-energized before performing any cleaning or inspection near terminals.
This product complies with the essential requirements of relevant EU Directives. It carries the CE mark. It meets grid connection standards such as VDE-AR-N 4105, G98/G99 (UK), and others as per regional versions. The inverter incorporates safety isolation and anti-islanding protection. Copyright © 2023 Solar PV LOGIC. For technical support, registration, and warranty claims, visit www.solarpvlogic.com/support or contact your local installer.
| Symptom / Error Code | Possible Cause | Corrective Action |
|---|---|---|
| Inverter not starting (No display) | No DC power / AC power | Check DC switch is ON and PV strings are producing voltage. Check AC switch and grid supply. |
| FAULT LED on, Code E01 | Grid Voltage High/Low | Inverter has detected abnormal grid voltage. Wait for grid to stabilize. If persistent, contact your DNO (Distribution Network Operator). |
| FAULT LED on, Code E04 | Isolation Resistance Low | Possible insulation fault in DC side. Contact a qualified installer to check PV array wiring and module insulation. |
| FAULT LED on, Code E10 | Over-temperature | Inverter too hot. Ensure installation location is shaded/ventilated. Clear any obstructions from ventilation slots. |
| No Wi-Fi connection | Weak signal / wrong credentials | Move router closer or use Wi-Fi extender. Re-configure Wi-Fi settings via the app. |
| Low energy production | Shading, dirty panels, weather | Check for new shading objects (e.g., tree growth). Clean PV panels if dirty. Compare to expected yield for your location and season. |
Reset: For transient faults, turning the DC and AC switches OFF, waiting 5 minutes, and then turning them back ON may clear the error. For persistent faults, note the error code and contact support.
Support: www.solarpvlogic.com/support | Phone: [Regional Support Number]