Smart Solar 10392M01 Manual

The Smart Solar 10392M01 is a high-efficiency solar charge controller designed for off-grid and backup power systems. It features MPPT (Maximum Power Point Tracking) technology, LCD display for real-time monitoring, multiple battery type support (Sealed, Gel, Flooded, LiFePO4), load control, temperature compensation, and comprehensive protection against overcharge, over-discharge, short circuit, and reverse polarity. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operating Modes 8. Protection Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: MPPT charge controller, LCD display, PV input terminals, Battery terminals, Load output terminals, Temperature sensor port.

FeatureDescription
MPPT TechnologyMaximizes solar energy harvest from PV panels
LCD DisplayShows PV voltage, battery voltage, charging current, load status, and error codes
Battery Type SelectionSupports Sealed, Gel, Flooded, and LiFePO4 batteries
Load ControlProgrammable timer and manual on/off for DC loads
Temperature CompensationAutomatically adjusts charging voltage based on battery temperature
Communication PortRS485 or USB for data monitoring and firmware updates
PV Input TerminalsFor connecting solar panel array (max 100V DC)
Battery TerminalsFor connecting battery bank (12V/24V auto-detect)
Load TerminalsFor connecting DC loads (lights, fans, etc.)
Protection FeaturesOvercharge, over-discharge, short circuit, reverse polarity, over-temperature

Installation

Unpack and inspect contents. Mount in a dry, well-ventilated location.

  1. Mount the controller: Use provided screws to mount on a vertical surface.
  2. Connect battery first: Ensure battery voltage matches controller rating (12V/24V). Connect positive (+) and negative (-) terminals securely.
  3. Connect PV panels: Connect solar panel array to PV input terminals, observing correct polarity.
  4. Connect load: Connect DC loads to load output terminals if needed.
  5. Connect temperature sensor (optional): Plug into designated port for accurate temperature compensation.

WARNING! Always connect battery before PV panels to avoid damage. Ensure all connections are tight and correct polarity is observed.

First-Time Setup

Power on controller; LCD will display system status.

  1. Set battery type: Press SET button, navigate to battery type menu, select appropriate type (Sealed, Gel, Flooded, LiFePO4).
  2. Set charging parameters: Adjust bulk/absorption voltage, float voltage, and equalization settings as per battery manufacturer specifications.
  3. Set load control: Configure load output mode (Manual, Timer, or Darkness ON).
  4. Set system voltage: Controller auto-detects 12V/24V; verify on display.

CAUTION! Incorrect battery settings can damage battery. Refer to battery datasheet for recommended voltages.

Specifications

Controls and Settings

Access settings via buttons on front panel. Buttons: SET, UP, DOWN, ENTER, LOAD ON/OFF.

LCD Display Icons: Battery level, PV input, load status, fault indicators.

Menu Structure: Battery type, Charging voltage (Bulk, Float, Equalize), Load control mode (Manual/Timer/Darkness), System info (Voltage, Current, Energy), Factory reset.

Load Timer: Set ON and OFF times for daily operation. Darkness Mode: Load turns on at dusk, off at dawn based on PV voltage.

Connecting Devices

Battery: Use thick cables (min 6mm²) to minimize voltage drop. PV: Ensure PV open-circuit voltage does not exceed 100V DC. Load: Max load current 30A.

  1. Turn off all power sources before making connections.
  2. Use appropriate cable lugs and tighten terminals to 2.0 N·m.
  3. Connect in order: Battery → PV → Load.
  4. Use external fuse (40A) on battery positive line for safety.

Tip: Keep cable runs as short as possible between battery and controller to reduce power loss.

Operating Modes

Controller operates in Bulk, Absorption, Float, and Equalization modes automatically.

  1. Bulk Mode: Full available current charges battery until voltage reaches absorption setpoint.
  2. Absorption Mode: Voltage held constant at absorption voltage while current tapers.
  3. Float Mode: After absorption, voltage drops to float voltage to maintain battery.
  4. Equalization Mode: Periodic overcharge for flooded batteries to prevent stratification (user configurable).
  5. Load Control: Load can be manually turned on/off or set to timer/darkness mode.

WARNING! Do not disconnect battery while PV is connected and producing power. Always disconnect PV first.

Protection Features

Overcharge Protection: Stops charging when battery voltage exceeds set limit. Over-discharge Protection: Disconnects load when battery voltage drops too low (adjustable). Short Circuit Protection: Automatically cuts off load output in case of short. Reverse Polarity Protection: Protects controller from damage if battery/PV connections are reversed. Over-temperature Protection: Reduces charging current if internal temperature exceeds 80°C.

Care & Maintenance

Periodically check terminal tightness. Clean dust from ventilation slots with dry cloth. Ensure no water ingress.

CAUTION! Do not open enclosure; no user-serviceable parts inside. Contact qualified technician for internal issues.

Regulatory Information

Complies with IEC 62109-1 safety standard for power converters. EMC tested per EN 55014. CE marked for European market. Copyright © 2025 Smart Solar; trademarks of Smart Solar Technologies. For support, visit www.smartsolar-tech.com or contact +1-800-555-1039.

Troubleshooting

SymptomPossible CauseCorrective Action
No display / not powering onBattery not connected / low voltageCheck battery connections and voltage (min 9V for 12V system).
Not charging from PVPV voltage too low / wrong polarityCheck PV connections, measure PV voltage in sunlight (must be higher than battery voltage).
Load not turning onBattery low / load mode settingCheck battery voltage; verify load control mode setting (Manual vs Timer).
Error code on displayVarious faults (E01-E10)Refer to manual error code list: E01=Over-temperature, E02=Battery overvoltage, etc.
Reduced charging currentHigh temperature / shading on PVEnsure controller is in cool location; check for PV panel shading or dirt.

Reset: Hold SET button for 10 seconds to restore factory defaults (settings will be lost).

Service: +1-800-555-1039; www.smartsolar-tech.com