The Smart Solar 10392M01 is a high-efficiency solar charge controller designed for off-grid and backup power systems. It features MPPT (Maximum Power Point Tracking) technology, LCD display for real-time monitoring, multiple battery type support (Sealed, Gel, Flooded, LiFePO4), load control, temperature compensation, and comprehensive protection against overcharge, over-discharge, short circuit, and reverse polarity. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: MPPT charge controller, LCD display, PV input terminals, Battery terminals, Load output terminals, Temperature sensor port.
| Feature | Description |
|---|---|
| MPPT Technology | Maximizes solar energy harvest from PV panels |
| LCD Display | Shows PV voltage, battery voltage, charging current, load status, and error codes |
| Battery Type Selection | Supports Sealed, Gel, Flooded, and LiFePO4 batteries |
| Load Control | Programmable timer and manual on/off for DC loads |
| Temperature Compensation | Automatically adjusts charging voltage based on battery temperature |
| Communication Port | RS485 or USB for data monitoring and firmware updates |
| PV Input Terminals | For connecting solar panel array (max 100V DC) |
| Battery Terminals | For connecting battery bank (12V/24V auto-detect) |
| Load Terminals | For connecting DC loads (lights, fans, etc.) |
| Protection Features | Overcharge, over-discharge, short circuit, reverse polarity, over-temperature |
Unpack and inspect contents. Mount in a dry, well-ventilated location.
WARNING! Always connect battery before PV panels to avoid damage. Ensure all connections are tight and correct polarity is observed.
Power on controller; LCD will display system status.
CAUTION! Incorrect battery settings can damage battery. Refer to battery datasheet for recommended voltages.
Access settings via buttons on front panel. Buttons: SET, UP, DOWN, ENTER, LOAD ON/OFF.
LCD Display Icons: Battery level, PV input, load status, fault indicators.
Menu Structure: Battery type, Charging voltage (Bulk, Float, Equalize), Load control mode (Manual/Timer/Darkness), System info (Voltage, Current, Energy), Factory reset.
Load Timer: Set ON and OFF times for daily operation. Darkness Mode: Load turns on at dusk, off at dawn based on PV voltage.
Battery: Use thick cables (min 6mm²) to minimize voltage drop. PV: Ensure PV open-circuit voltage does not exceed 100V DC. Load: Max load current 30A.
Tip: Keep cable runs as short as possible between battery and controller to reduce power loss.
Controller operates in Bulk, Absorption, Float, and Equalization modes automatically.
WARNING! Do not disconnect battery while PV is connected and producing power. Always disconnect PV first.
Overcharge Protection: Stops charging when battery voltage exceeds set limit. Over-discharge Protection: Disconnects load when battery voltage drops too low (adjustable). Short Circuit Protection: Automatically cuts off load output in case of short. Reverse Polarity Protection: Protects controller from damage if battery/PV connections are reversed. Over-temperature Protection: Reduces charging current if internal temperature exceeds 80°C.
Periodically check terminal tightness. Clean dust from ventilation slots with dry cloth. Ensure no water ingress.
CAUTION! Do not open enclosure; no user-serviceable parts inside. Contact qualified technician for internal issues.
Complies with IEC 62109-1 safety standard for power converters. EMC tested per EN 55014. CE marked for European market. Copyright © 2025 Smart Solar; trademarks of Smart Solar Technologies. For support, visit www.smartsolar-tech.com or contact +1-800-555-1039.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display / not powering on | Battery not connected / low voltage | Check battery connections and voltage (min 9V for 12V system). |
| Not charging from PV | PV voltage too low / wrong polarity | Check PV connections, measure PV voltage in sunlight (must be higher than battery voltage). |
| Load not turning on | Battery low / load mode setting | Check battery voltage; verify load control mode setting (Manual vs Timer). |
| Error code on display | Various faults (E01-E10) | Refer to manual error code list: E01=Over-temperature, E02=Battery overvoltage, etc. |
| Reduced charging current | High temperature / shading on PV | Ensure controller is in cool location; check for PV panel shading or dirt. |
Reset: Hold SET button for 10 seconds to restore factory defaults (settings will be lost).
Service: +1-800-555-1039; www.smartsolar-tech.com