The Samlex Solar SBC-2 is a 2-Bank Solar Battery Charger designed for efficient and safe charging of two separate 12V lead-acid batteries (flooded, AGM, or Gel) from a single solar panel array. It features Maximum Power Point Tracking (MPPT) technology, intelligent 3-stage charging, comprehensive protection systems, and an LCD display for monitoring. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: MPPT Charge Controller, LCD Display, PV Input Terminals, Battery Bank 1 & 2 Output Terminals, Load Output Terminals, Temperature Sensor Port.
| Feature | Description |
|---|---|
| MPPT Technology | Maximizes energy harvest from solar panels |
| Dual Independent Charging | Charges two separate 12V battery banks simultaneously |
| 3-Stage Charging | Bulk, Absorption, Float for battery health and longevity |
| LCD Display | Shows PV voltage/current, battery voltage, charging stage, fault codes |
| Temperature Compensation | Adjusts charge voltage based on battery temperature (sensor included) |
| Protections | Reverse polarity, over-current, over-voltage, short-circuit, over-temperature |
| Load Control | Programmable DC load output with low-voltage disconnect (LVD) |
| Communication Port | For potential system monitoring (optional) |
| User Settings | Selectable battery type, charging parameters, load control modes |
| Robust Construction | Designed for marine, RV, and off-grid environments |
Unpack and inspect contents. Mount in a dry, well-ventilated location.
WARNING! Disconnect all power sources before making connections. Ensure all connections are tight and correct to prevent damage or fire.
Once installed, power will flow from the solar panel. The LCD will illuminate.
CAUTION! Never connect an AC source or a charged battery in reverse polarity. Use appropriate cable sizes to handle maximum current.
Access settings via the front panel buttons (MODE, ENTER, UP, DOWN). LCD Display shows status and menus.
Buttons: MODE (navigate menus), ENTER (select/save), UP/DOWN (adjust values).
Menu Settings: Battery Type Selection, Charging Voltage Setpoints (Absorption, Float), Load Control Mode (Manual, Timer, LVD), System Voltage Display, Temperature Compensation Enable/Disable, Reset to Factory Defaults.
Display Information: PV Voltage & Current, Battery 1 & 2 Voltage, Charging Stage (Bulk, Absorb, Float), Charging Current per Bank, Load Status, Error Codes.
PV Input: Connect solar panel array. Battery Outputs: Connect to Battery Bank 1 and Bank 2. Load Output: Connect DC loads (lights, fans).
Tip: Follow the connection sequence: 1. Battery, 2. PV, 3. Load. Disconnect in reverse order.
Automatically manages the 3-stage charging process for each battery bank independently.
WARNING! Do not connect a DC-DC converter or another charger to the load terminals. The load output is for DC loads only.
Reverse Polarity Protection: Prevents damage if PV or battery leads are reversed. Over-Current Protection: Limits output current. Over-Voltage Protection: Protects battery from excessive voltage. Short-Circuit Protection: On load output. Over-Temperature Protection: Reduces charge current if controller overheats. Low-Voltage Disconnect (LVD): Protects batteries from deep discharge by disconnecting loads.
Periodically check all terminal connections for tightness and signs of corrosion. Keep the unit clean and free of dust. Ensure ventilation is not blocked. Inspect wiring insulation regularly.
CAUTION! Do not open the controller case. There are no user-serviceable parts inside. Contact qualified service personnel.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. ETL Listed to UL Standard 1741 and CSA C22.2 No. 107.1. Copyright © Samlex Solar. All trademarks are the property of their respective owners. For technical support, visit www.samlexsolar.com or contact 1-800-123-4567.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display / unit not powering on | No battery connection / blown fuse | Check battery connections and polarity. Check and replace fuse on battery positive cable. |
| Not charging / No PV current | Poor sunlight, faulty panel, wiring issue | Check PV voltage at controller terminals. Ensure panels are clean and in sun. Check all PV connections and fuses. |
| Battery voltage too low / not reaching float | Undersized PV, high load, faulty battery | Check if PV power is sufficient for load and charging. Test battery health. Reduce load. |
| Load output not working | Load disconnected by LVD, setting incorrect | Check battery voltage. Check Load Control settings in menu. Ensure load is within current rating. |
| Error code on display (e.g., E01, E02) | Specific fault condition | Refer to "Error Codes" section in the full manual for diagnosis and corrective steps. |
Reset: Disconnect PV and battery, wait 60 seconds, then reconnect battery first, then PV.
Service: 1-800-123-4567; www.samlexsolar.com