The Samlex Solar MC4-2 is a high-quality, waterproof MC4 branch connector designed for connecting two solar panels in parallel to a single charge controller or inverter input. It features male and female MC4 connectors on one end and a single MC4 output on the other, built with UV-resistant housing and gold-plated contacts for optimal conductivity and durability in outdoor environments. Below are key sections for safety, features, installation, specifications, operation, and troubleshooting.
Key components: Waterproof MC4 housing, Gold-plated contacts, UV-resistant material, Integrated strain relief, Polarity markings.
| Feature | Description |
|---|---|
| Connector Type | MC4 compatible, IP67 rated for waterproofing |
| Configuration | 2-to-1 parallel branch connector |
| Contact Material | Gold-plated copper for low resistance and corrosion resistance |
| Housing Material | UV-resistant thermoplastic |
| Cable Gauge | Compatible with 10 AWG to 14 AWG PV cable |
| Voltage Rating | Rated for up to 1000V DC |
| Current Rating | Rated for up to 30A per input, 30A output |
| Temperature Range | -40°C to +90°C operating temperature |
| Polarity Marking | Clear "+" and "-" indicators on housing |
| Strain Relief | Integrated cable grip for secure connection |
Unpack and inspect contents. Ensure all components are present and undamaged.
WARNING! Always disconnect the solar array from the charge controller and battery before making connections. Ensure all connections are dry and secure.
Integrate the MC4-2 into your solar array during initial system assembly.
CAUTION! Connecting panels with mismatched voltages in parallel can lead to reduced efficiency and potential damage. Always verify specifications.
The MC4-2 uses standard MC4 compatible interfaces. The locking mechanism provides a secure, waterproof connection.
Connector Parts: Housing (Male/Female), Contact Pin/Socket, Seal, Cap (if included).
Locking Mechanism: Push connectors together until a click is heard. To disconnect, press the locking tab and pull apart firmly.
Polarity: Male connector typically carries the positive (+) line. Female connector typically carries the negative (-) line. Always verify with system diagram.
For parallel connection of two solar panels to increase current while maintaining voltage.
Tip: Use a multimeter to check for short circuits before connecting to the charge controller.
The MC4-2 is designed for integration into grid-tied or off-grid solar systems.
WARNING! Do not exceed the maximum current rating of the MC4-2 (30A) or the downstream components. Use appropriate overcurrent protection (fuses/breakers).
IP67 Rating: Protects against dust and temporary immersion. Live Parts Protection: Fully insulated contacts prevent accidental contact. Strain Relief: Prevents cable pull-out and damage to connections. Polarized Design: Prevents reverse polarity connection.
Periodically inspect connectors for dirt, corrosion, or damage. Clean with a dry cloth if necessary.
CAUTION! Do not submerge connectors while the system is live. Do not use solvents or abrasive cleaners. Check seals for cracks and replace if damaged.
This product complies with relevant safety and performance standards for photovoltaic connectors. It is designed for use in accordance with the National Electrical Code (NEC) and other local regulations. Samlex Solar is a trademark of Samlex America Inc. For technical support and warranty information, visit www.samlexsolar.com or contact 1-800-561-5885.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No output current | Loose connection, incorrect polarity | Check and reseat all MC4 connections. Verify polarity with a multimeter. |
| Connector overheating | High resistance, exceeded current rating | Check for damaged contacts or corrosion. Ensure total current is below 30A. |
| Water ingress | Damaged seal, improper connection | Inspect and replace seal. Ensure connector is fully clicked and locked. |
| Difficult to connect/disconnect | Dirt/debris in connector, damaged locking tab | Clean contacts with electrical contact cleaner. Do not force connection. |
| Voltage drop across connector | Poor contact, corrosion | Disconnect, clean gold-plated contacts, and reconnect securely. |
Replacement: If damaged, replace the entire MC4-2 connector. Do not attempt to repair.