Rockpals PA-SP003 User Manual

The Rockpals PA-SP003 is a portable power station designed for outdoor adventures, emergency backup, and off-grid power needs. It features a high-capacity lithium battery, multiple output ports (AC, DC, USB), solar charging capability, LCD display for monitoring, and safety protections. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Charging the Unit 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Lithium-ion battery pack, LCD display, AC outlets, DC car port, USB ports, Solar charging input, Power button, LED flashlight.

FeatureDescription
AC OutputPure sine wave AC outlet for sensitive electronics
DC Output12V car port for car appliances
USB PortsMultiple USB-A and USB-C ports for mobile devices
Solar InputMC4 connector for solar panel charging
LCD DisplayShows battery level, input/output power, and status
LED FlashlightBuilt-in emergency light with multiple modes
Power ButtonTurns unit on/off
Overload ProtectionAutomatic shutdown if overload detected
Battery Management SystemProtects against overcharge, over-discharge, short circuit
Carrying HandleIntegrated handle for portability

Installation

Unpack and inspect contents. Place on stable, dry surface.

  1. Initial Charge: Connect included AC adapter to unit and wall outlet for full charge.
  2. Positioning: Ensure unit is in a well-ventilated area, away from heat sources and moisture.
  3. Solar Panel Setup: Connect compatible solar panel to solar input port if using solar charging.
  4. Device Connections: Connect devices to appropriate output ports based on power requirements.

WARNING! Unit contains heavy battery; lift with care using both hands. Keep away from water and extreme temperatures.

First-Time Setup

Power on unit; monitor LCD display.

  1. Charge fully: Use AC adapter to charge to 100% before first use.
  2. Check display: Verify battery level and output status on LCD screen.
  3. Test outputs: Connect a small device to each output type to ensure functionality.
  4. Configure settings: Use power button to toggle flashlight modes if needed.

CAUTION! Do not disassemble unit. Use only provided or recommended accessories.

Specifications

Controls and Settings

Access functions via physical buttons and LCD interface. Front Panel: POWER button, LCD display, output ports.

Controls: POWER (press to turn on/off, hold for flashlight), AC output button, DC output button, USB ports (always on when unit is on).

LCD Display: Shows battery percentage, input power (if charging), output power (if devices connected), estimated time remaining. Settings: Flashlight mode cycle (press and hold power button), Eco mode (auto-shutdown if no load detected).

Connecting Devices

AC Devices: Plug into AC outlet. DC Devices: Use 12V car port. USB Devices: Connect to USB-A or USB-C ports.

  1. Ensure unit is powered on.
  2. Check device power requirements (do not exceed unit's rated output).
  3. Connect device to appropriate port.
  4. Monitor LCD for output power and battery drain.

Tip: For high-power devices (e.g., mini-fridge), start with unit fully charged and monitor battery level.

Charging the Unit

Supports AC wall charging, solar charging, and 12V car charging.

  1. AC Charging: Connect AC adapter to unit and wall outlet. LCD will show charging status.
  2. Solar Charging: Connect compatible solar panel to solar input port. Ensure direct sunlight.
  3. Car Charging: Use 12V car charger adapter while vehicle is running.
  4. Charging Time: Approx. 6 hours via AC, 8-10 hours via solar (depending on panel).
  5. Battery Care: For longevity, avoid frequent full discharges; recharge when battery drops to 20-30%.

WARNING! Use only recommended solar panels and chargers. Do not charge in temperatures below 32°F or above 104°F.

Safety Features

Overload Protection: Automatically shuts off output if exceeded. Short Circuit Protection: Cuts power if short detected. Temperature Control: Prevents overheating. Low Voltage Protection: Shuts down if battery too low to prevent damage.

Care & Maintenance

Store in cool, dry place. Clean with dry cloth only; do not use liquids. Recharge every 3 months if storing long-term.

CAUTION! Do not expose to rain or submersion. Avoid impacts or punctures to battery casing.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits. UL and CE certified for safety. Copyright © 2025 Rockpals; trademarks of Rockpals. For support, visit www.rockpals.com or contact [email protected].

Troubleshooting

SymptomPossible CauseCorrective Action
Unit won't turn onBattery depletedCharge unit fully via AC adapter.
No output powerOverload protection triggeredDisconnect devices, turn unit off/on, reconnect lower-power device.
Solar not chargingInsufficient sunlight/connectionEnsure direct sunlight, check cable connections, verify panel compatibility.
LCD display blankUnit off or battery deadPress power button; if no response, charge unit.
Device not charging via USBFaulty cable/portTry different cable; try different USB port.
OverheatingHigh ambient temp/overloadMove to cooler area, disconnect devices, allow to cool.

Reset: Turn unit off, disconnect all devices, wait 1 minute, turn back on.

Service: [email protected]; www.rockpals.com

Rockpals PA-SP003 User Manual © - All Rights Reserved 2025