Prouser SCP50 Operating Manual

The Prouser SCP50 is a high-precision industrial sensor controller with advanced signal processing, multiple I/O interfaces, configurable alarm thresholds, data logging capabilities, and robust communication protocols. Designed for harsh environments, it features IP67-rated housing, wide operating temperature range, and intuitive configuration software. Below are key sections for safety, features, installation, configuration, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operating Modes 8. Advanced Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main processing unit, Display interface, Power terminal, Sensor inputs (analog/digital), Relay outputs, Communication ports (RS-485, Ethernet), Configuration buttons.

FeatureDescription
Power terminalFor 24V DC power supply connection
Sensor inputs4x analog (4-20mA/0-10V) + 2x digital
Relay outputs2x SPDT relay outputs (250VAC, 5A)
Communication portsRS-485 Modbus RTU + Ethernet TCP/IP
Display interface128x64 pixel LCD with backlight
Configuration buttons5-button navigation and menu access
PROGRAMEnters configuration mode
UP/DOWNNavigates menus and adjusts values
ENTERConfirms selection
ESCExits menu or cancels operation

Installation

Unpack and inspect contents. Mount on DIN rail or flat surface.

  1. Mounting: Secure to DIN rail (EN 50022) using clip; ensure proper ventilation.
  2. Power connection: Connect 24V DC to power terminals observing polarity.
  3. Sensor wiring: Connect sensors to appropriate input terminals.
  4. Output wiring: Connect relay outputs to controlled devices.
  5. Communication: Connect RS-485 or Ethernet cable as required.

WARNING! Disconnect power before wiring. Ensure proper grounding to prevent electrical shock.

First-Time Setup

Apply power; follow initialization sequence.

  1. Power on: Connect 24V DC; controller performs self-test.
  2. Basic configuration: Press PROGRAM to enter setup; navigate with UP/DOWN.
  3. Set measurement units: Select appropriate units for each input channel.
  4. Configure alarm thresholds: Set high/low limits for each monitored parameter.
  5. Set communication parameters: Configure Modbus address and baud rate.
  6. Save configuration: Press ENTER to save and exit setup mode.

CAUTION! Verify wiring before applying power. Use appropriate wire gauges.

Specifications

Controls and Settings

Access menu via PROGRAM button. Front Panel: PROGRAM, UP, DOWN, ENTER, ESC.

Display Indicators: Power, Alarm, Communication status LEDs.

Configuration Menu: Input setup (type, range, filtering), Output setup (relay logic, hysteresis), Alarm configuration (thresholds, delays), Communication setup (protocol, address, baud rate), System settings (display contrast, backlight timeout, password).

Default password: 0000. Change in SYSTEM > SECURITY menu.

Connecting Devices

Sensors: Connect to appropriate input terminals. Outputs: Connect to relay terminals. Communication: RS-485 daisy-chain or Ethernet direct.

  1. Turn off power before connecting devices.
  2. Use shielded cables for analog signals; ground shield at one end.
  3. For RS-485: Connect A to A, B to B; terminate with 120Ω resistor at ends.
  4. For Ethernet: Use standard CAT5e or better cable.

Tip: Label all wires for easy identification during maintenance.

Operating Modes

Supports normal monitoring, calibration, and diagnostic modes.

  1. Normal operation: Displays real-time values; triggers alarms when thresholds exceeded.
  2. Calibration mode: Access via hidden menu (PROGRAM + ENTER for 5 seconds).
  3. Diagnostic mode: Displays system status, error logs, communication statistics.
  4. Data logging: Stores min/max/average values (configurable interval).
  5. Manual override: Force relay states for testing via OUTPUT TEST menu.

WARNING! Calibration should be performed by qualified personnel only.

Advanced Features

Mathematical functions: Scaling, linearization, totalization. Communication: Modbus mapping for all parameters. Security: Password protection for configuration changes.

Care & Maintenance

Disconnect power before maintenance. Clean with dry cloth; ensure ventilation slots remain clear.

CAUTION! Do not use solvents or abrasives. Check connections periodically for corrosion.

Regulatory Information

CE compliant: Meets EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU. RoHS compliant: Contains no restricted substances per Directive 2011/65/EU. For support, visit www.prouser-tech.com or contact +1-800-555-1234.

Troubleshooting

SymptomPossible CauseCorrective Action
No displayPower issueCheck power connections; verify 24V DC supply.
Incorrect readingsSensor/wiringVerify sensor connections; check for proper grounding.
Communication failureCable/parametersCheck cable continuity; verify Modbus address and baud rate.
Relay not operatingConfiguration/loadCheck relay configuration; verify load within specifications.
Frequent alarmsThresholds/noiseAdjust alarm hysteresis; check for electrical noise.

Reset: SYSTEM > FACTORY RESET (requires password).

Service: +1-800-555-1234; www.prouser-tech.com/support

Prouser SCP50 Operating Manual © - All Rights Reserved 2025