The Prouser SCM30 is a high-precision industrial smart sensor module designed for real-time monitoring and control applications. It features a 30mm sensing range, digital I/O interfaces, configurable analog outputs, IP67-rated housing, programmable logic functions, and communication via RS-485 Modbus RTU. Operating on 12-24V DC, it includes built-in diagnostics, temperature compensation, and software configuration tools. Below are key sections for safety, features, installation, configuration, operation, and troubleshooting.
Key components: Sensing head with integrated electronics, Configuration cable, Mounting bracket, Status LEDs, Digital outputs, Analog voltage/current outputs.
| Feature | Description |
|---|---|
| Sensing Range | 0-30mm with ±0.1mm repeatability |
| Outputs | 2x PNP/NPN configurable, 1x analog (0-10V/4-20mA) |
| Input Voltage | 12-24V DC ±10% |
| Communication | RS-485 Modbus RTU (address 1-247) |
| Housing | IP67 rated stainless steel M30 housing |
| Status Indicators | Power (green), Output (yellow), Fault (red) |
| Response Time | Adjustable 1ms to 100ms |
| Temperature Range | -25°C to +70°C operating |
| Teach Function | One-button teach for setpoint programming |
| Logic Functions | AND/OR, window mode, hysteresis adjustment |
Unpack and inspect contents. Ensure proper mounting location.
WARNING! Disconnect power before installation. Ensure proper grounding to prevent electrical damage.
Power on sensor; follow configuration steps.
CAUTION! Ensure target material matches calibration material for accurate measurements.
Access settings via TEACH button or configuration software. Front Panel: Power LED, Output LED, Fault LED, TEACH button.
Software Interface: Prouser ConfigTool for Windows. Parameters: Sensing mode, Output logic, Hysteresis, Response time, Analog scaling, Communication settings.
Digital Outputs: Configurable as normally open/closed, light/dark operate. Analog Output: Selectable 0-10V or 4-20mA, linear/inverse scaling. Advanced: Temperature compensation, filtering, multi-point calibration.
Power: 12-24V DC. PLC: Digital inputs. Controller: Analog input. Network: RS-485 daisy chain.
Tip: Keep communication cables separate from power cables to reduce noise.
Supports multiple detection and output modes.
WARNING! Do not exceed maximum switching frequency of 1kHz to prevent damage.
Temperature Compensation: Automatic adjustment for ambient temperature changes. Diagnostics: Built-in fault detection for overload, short circuit, temperature. Data Logging: Store up to 1000 measurement values (optional). Multi-sensor Synchronization: Coordinate multiple sensors via RS-485.
Disconnect power before maintenance. Clean sensing face with isopropyl alcohol and soft cloth. Check mounting hardware quarterly for tightness.
CAUTION! Do not use abrasive cleaners or compressed air directly on sensing face. Avoid mechanical impacts.
EMC Directive 2014/30/EU: Complies with emission and immunity requirements. Low Voltage Directive 2014/35/EU: Safe for intended use. RoHS Directive 2011/65/EU: Contains no restricted substances above thresholds. Copyright © 2023 Prouser Technologies; all trademarks property of their owners. For support, visit www.prouser-tech.com or contact +1-800-555-8732.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power LED | Incorrect voltage/polarity | Verify 12-24V DC; check polarity; measure at terminals. |
| Erratic measurements | Electrical noise/grounding | Use shielded cable; ensure proper grounding; add filter. |
| Output not switching | Wrong mode/teaching | Re-teach switching points; verify output configuration. |
| Communication failure | Address/baud mismatch | Check Modbus address and baud rate; verify termination. |
| Red fault LED | Overload/short circuit | Check load current; verify wiring; power cycle. |
| Analog output drift | Temperature variation | Enable temperature compensation; recalibrate. |
Reset to Defaults: Hold TEACH button for 10 seconds during power-up.
Service: +1-800-555-8732; www.prouser-tech.com/support