Pni Green House 370W Manual

The Pni Green House 370W is a high-performance 370-watt grow light system designed for indoor horticulture, featuring full-spectrum LED technology, adjustable light intensity, daisy-chain connectivity, built-in cooling fans, waterproof rating (IP65), remote control, timer functionality, and energy-efficient operation. Suitable for various growth stages from seedling to flowering. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operating Modes 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: LED light panel with full-spectrum diodes, Remote Control, Power input, Daisy-chain ports, Cooling fans, Hanging hooks, Control panel.

FeatureDescription
LED Panel370W full-spectrum LEDs for all growth stages
Daisy-chain portsFor connecting multiple units in series
Cooling fansBuilt-in for heat dissipation
Hanging hooksAdjustable for height positioning
Power inputFor AC power connection
Control panelManual buttons for power, mode, intensity
Remote controlWireless control of all functions
Timer functionProgrammable on/off cycles
Waterproof ratingIP65 for humid environments
Intensity adjustment0-100% dimmable via remote

Installation

Unpack and inspect contents. Ensure mounting surface can support weight.

  1. Mount light: Use hanging hooks; secure to ceiling or rack with included hardware.
  2. Connect power: Plug AC cord into grounded outlet.
  3. Daisy-chain multiple units: Connect output port of first unit to input of next using provided cable.
  4. Position light: Adjust height according to plant stage (see recommendations).

WARNING! Unit is heavy; use two people for installation. Ensure secure mounting to prevent falls.

First-Time Setup

Power on light; follow initial configuration.

  1. Pair remote: Point remote at receiver; press POWER and MODE simultaneously for 3 seconds.
  2. Set timer: Use TIMER button to program daily on/off schedule.
  3. Adjust spectrum: Select mode (VEG, BLOOM, FULL) for plant stage.
  4. Calibrate intensity: Start at 50% for seedlings; increase gradually.

CAUTION! Keep light at recommended distance from plants to prevent light burn.

Specifications

Controls and Settings

Access functions via control panel or remote. Control Panel: POWER, MODE, INTENSITY UP/DOWN.

Remote: POWER, VEG, BLOOM, FULL SPECTRUM, TIMER, INTENSITY +/-, DAISY-CHAIN SYNC.

Modes: VEG (blue-heavy), BLOOM (red-heavy), FULL (balanced). Intensity: Adjustable 0-100% in 10% increments. Timer: Set start/stop times for automatic operation. Daisy-chain: Master unit controls slave units when synced.

Connecting Devices

Daisy-chain: Connect units in series. Remote: Infrared line-of-sight required.

  1. Turn off all units before connecting.
  2. Use provided cables for daisy-chain connections.
  3. Designate master unit; sync others via remote.

Tip: Ensure all connections are secure and cables are not pinched.

Operating Modes

Supports three primary modes for different growth stages.

  1. VEG mode: Emphasizes blue spectrum (400-500nm) for vegetative growth.
  2. BLOOM mode: Emphasizes red spectrum (620-780nm) for flowering.
  3. FULL SPECTRUM: Balanced light for all stages.
  4. Manual adjustment: Use intensity control to fine-tune brightness.
  5. Timer operation: Set schedule for consistent light cycles.
  6. Daisy-chain operation: Control multiple units from one remote.

WARNING! Do not look directly at LEDs at close range. Use protective eyewear if servicing.

Safety Features

Overheat protection: Auto-shutdown at 158°F. Waterproof: IP65 rating for splashes. Surge protection: Built-in for power fluctuations. Cooling: Fans auto-adjust based on temperature.

Care & Maintenance

Unplug before cleaning. Wipe housing with dry cloth; clean LED surface with soft, dry brush.

CAUTION! Do not use water or cleaning solutions on electrical components. Check fans regularly for dust buildup.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits. ETL listed for safety standards. Copyright © 2025 Pni Green House; trademarks of Pni Horticulture Inc. For support, visit www.pnigreenhouse.com or contact 1-800-555-370W.

Troubleshooting

SymptomPossible CauseCorrective Action
Light not turning onPower connection/remoteCheck power cord; ensure outlet works; replace remote batteries.
Fans not runningOverheat/obstructionAllow unit to cool; check for blockages in fan vents.
Uneven light distributionHeight/positionAdjust height; ensure level installation.
Daisy-chain not workingCables/syncCheck cable connections; re-sync units via remote.
Timer not functioningProgramming/powerReprogram timer; ensure continuous power to unit.

Reset: Unplug for 60 seconds to reset control board.

Service: 1-800-555-370W; www.pnigreenhouse.com

Pni Green House 370W Manual © - All Rights Reserved 2025