Oz Charge OC-SR10 User Manual

The Oz Charge OC-SR10 is a 10-inch Solar-Ready Portable Power Station with a high-efficiency lithium-ion battery, integrated MPPT solar charge controller, multiple AC/DC/USB outputs, LCD status display, built-in LED flashlight, and support for solar panel input. Designed for outdoor, emergency, and off-grid power needs. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Solar Charging 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Lithium-ion Battery Pack, LCD Display Panel, Solar Charge Input Port, AC Output Sockets, DC Output Ports, USB-A & USB-C Ports, LED Flashlight, Carrying Handle.

FeatureDescription
Solar Charge InputFor connecting compatible solar panels (max 100W)
AC Output (Pure Sine Wave)Two 110V AC sockets for small appliances
DC Output Ports12V/10A car-style socket for DC devices
USB-A PortsTwo 5V/2.4A ports for smartphones/tablets
USB-C PD PortOne 60W Power Delivery port for fast charging
LCD DisplayShows battery level, input/output power, status icons
LED FlashlightBuilt-in emergency light with SOS mode
POWER ButtonTurns unit and outputs on/off
Flashlight ButtonControls LED light modes (On/Off/SOS)
AC Input PortFor wall charging (included adapter)

Installation

Unpack and inspect contents. Place on stable, dry surface.

  1. Initial Charge: Connect included AC adapter to AC Input port and wall outlet. Charge fully (LED indicator solid green).
  2. Connect Solar Panel (Optional): Use compatible solar panel cable to connect to Solar Charge Input port.
  3. Positioning: Ensure unit is in a well-ventilated area, away from direct heat sources and moisture.
  4. Connect Devices: Plug devices into appropriate output ports after unit is powered on.

WARNING! Do not disassemble the unit. Keep away from water and extreme temperatures. Use only included or recommended accessories.

First-Time Setup

Power on the unit; observe LCD display.

  1. Initial Power-Up: Press and hold POWER button for 2 seconds. LCD will illuminate.
  2. Check Battery Level: Verify battery icon on LCD shows full or adequate charge.
  3. Configure Outputs: Use POWER button to enable/disable AC, DC, or USB banks individually via short presses (refer to LCD icons).
  4. Test Flashlight: Press Flashlight button to cycle through modes (High > Low > SOS > Off).

CAUTION! Ensure the unit is fully charged before first use for optimal battery calibration.

Specifications

Controls and Settings

Primary control via front panel buttons and LCD interface.

Front Panel: POWER Button, Flashlight Button, LCD Display.

LCD Icons: Battery Level (%), Input Power (W), Output Power (W), AC/DC/USB Status, Temperature Warning, Fault Indicator.

Settings via Button Press Sequences: - Hold POWER + Flashlight for 5s: Reset to factory defaults. - Double-press POWER: Toggle between Eco Mode (auto-shutdown) and Standard Mode. - Hold Flashlight for 3s in SOS mode: Activates beacon flash pattern.

Charging Modes: LCD shows "AC", "SOLAR", or "CAR" icon based on active input source.

Connecting Devices

AC Devices: Plug into AC outlets. DC Devices: Use 12V car adapter plug. USB Devices: Use appropriate cables.

  1. Ensure Oz Charge OC-SR10 is powered ON (LCD active).
  2. Check the power rating of your device does not exceed the port's maximum output.
  3. Connect device cable securely to the correct port.
  4. The LCD will update to show output wattage and remaining battery runtime estimate.

Tip: For devices with high startup surge (like small refrigerators), connect to AC output first, then turn the device on.

Solar Charging

Supports charging via compatible solar panels (sold separately).

  1. Panel Compatibility: Use solar panel with Open Circuit Voltage (Voc) between 12V-24V and max 100W power.
  2. Connection: Use the correct cable to connect panel's output to the unit's Solar Charge Input port.
  3. Positioning: Angle solar panel towards direct sunlight. LCD will show "SOLAR" icon and input wattage.
  4. Optimal Charging: Full charge time varies based on panel wattage and sunlight conditions (approx. 4-8 hours with 100W panel).
  5. MPPT Controller: Automatically optimizes input for maximum efficiency.

WARNING! Do not exceed max solar input specifications. Disconnect panel before cleaning or during storms. Avoid shading on the panel.

Safety Features

Overload Protection: Automatically shuts off output if exceeded. Short Circuit Protection: For all output ports. Over-temperature Protection: Reduces output or shuts down if overheated. Low-Temperature Charging Protection: Prevents charging if battery is below freezing. Battery Management System (BMS): Monitors cell voltage and health.

Care & Maintenance

Store in a cool, dry place. Recharge at least every 3 months if storing long-term. Clean exterior with a dry, soft cloth.

CAUTION! Do not immerse in water. Do not expose to temperatures above 104°F (40°C) or below 14°F (-10°C) for extended periods. Use only the provided or manufacturer-approved charging accessories.

Regulatory Information

FCC Part 15: Class B digital device; complies with limits for residential use. UL Certified: Meets safety standards for portable battery equipment. Copyright © 2025 Oz Charge; trademarks of Oz Charge Technologies, Inc. For support, visit www.ozcharge.com/support or contact 1-800-555-OC10.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit will not turn onBattery depletedConnect to AC wall charger or solar panel to recharge.
No output from portsEco Mode active / OverloadDisable Eco Mode (double-press POWER). Disconnect devices and restart unit.
Solar not chargingInsufficient sun / Wrong cableEnsure panel is in direct sunlight. Verify cable is properly connected to Solar Input port.
LCD shows fault iconOver-temperature / Short circuitTurn unit off, let cool in shaded area. Check connected device for shorts, then restart.
Rapid battery drainHigh load device / Old batteryCheck device wattage is within limits. After 500+ cycles, battery capacity may reduce (normal wear).

Reset: Hold POWER + Flashlight buttons for 10 seconds to perform a hard reset.

Service: 1-800-555-OC10; www.ozcharge.com/support

Oz Charge OC-SR10 User Manual © - All Rights Reserved 2025