The Orion ASLR050 is a high-performance, low-noise linear actuator designed for precise positioning in industrial automation, medical equipment, and home automation applications. It features a 12V DC motor, built-in limit switches, IP54-rated protection, manual override capability, and a compact design for easy integration. Below are key sections for safety, installation, wiring, operation, and troubleshooting.
Ensure all items are present before proceeding with installation.
| Item | Quantity | Description |
|---|---|---|
| ASLR050 Linear Actuator | 1 | Main actuator unit with mounting brackets |
| Control Box | 1 | Includes relay board and terminal connectors |
| Power Cable | 1 | 2-meter cable with DC plug |
| Mounting Hardware Kit | 1 | Screws, bolts, and washers |
| Quick Start Guide | 1 | This manual |
Read all instructions before installation and operation.
WARNING! Failure to follow safety instructions may result in injury or damage to the equipment.
Proper mounting is critical for safe and reliable operation.
Tip: Use a spirit level to ensure actuator is mounted horizontally if required by application.
Connect to a stable 12V DC power source.
| Terminal (Control Box) | Connection | Wire Color |
|---|---|---|
| V+ | Positive (+12V) | Red |
| V- | Negative (GND) | Black |
| IN1 | Extend Control Signal | Yellow |
| IN2 | Retract Control Signal | Green |
| COM | Signal Common | Blue |
CAUTION! Reverse polarity will damage the actuator. Double-check connections before powering on.
The actuator is controlled via two digital signals.
Note: Do not energize both IN1 and IN2 simultaneously.
In case of power failure, the actuator can be manually operated.
WARNING! Disconnect power before using manual override to prevent accidental activation.
Regular inspection ensures long service life.
CAUTION! Do not disassemble the actuator. Internal components are not user-serviceable.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Actuator does not move | No power / Wrong voltage | Check power supply output (12V DC). Verify polarity. |
| Moves in one direction only | Faulty control signal / wiring | Check IN1/IN2 connections and control signal voltage. |
| Stops before full stroke | Obstruction / Binding | Check for mechanical obstruction. Ensure proper alignment. |
| Overheating | Exceeded duty cycle / Overload | Allow to cool. Reduce load or operating frequency. |
| Unusual noise | Loose mounting / Internal issue | Tighten mounting bolts. If noise persists, contact support. |
Orion ASLR050 is covered by a 2-year limited warranty against defects in materials and workmanship under normal use. For technical support or warranty claims, contact:
Orion Automation Support
Phone: +1-800-555-ORION
Email: [email protected]
Website: www.orion-automation.com/support
Please have your model number and purchase receipt ready when contacting support.