The O.n 23.8757.41 is a precision measurement instrument designed for laboratory and industrial applications, featuring high-resolution digital display, multiple measurement modes, data logging capabilities, USB connectivity for PC interface, rechargeable battery operation, auto-calibration function, and robust construction for reliable performance. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: High-resolution LCD display, Measurement probe, Control panel, USB port, Battery compartment, Calibration port.
| Feature | Description |
|---|---|
| Measurement probe | Precision sensor for accurate readings |
| USB port | For data transfer and PC connectivity |
| Battery compartment | Holds rechargeable lithium-ion battery |
| Calibration port | For external calibration equipment connection |
| Power input connector | For charging and AC adapter connection |
| Control panel buttons | Mode selection, calibration, data logging controls |
| POWER | Turns instrument on/off |
| CALIBRATE | Initiates auto-calibration sequence |
| MODE | Cycles through measurement modes |
| DATA LOG | Starts/stops data logging function |
Unpack and inspect contents. Place on stable, level surface.
WARNING! Instrument contains sensitive electronics; handle with care to avoid damage. Ensure all connections are secure before operation.
Power on instrument; follow initialization sequence.
CAUTION! Perform calibration in stable environmental conditions. Allow instrument to acclimate to room temperature before use.
Access menu system via MENU button. Front Panel: POWER, CALIBRATE, MODE, DATA LOG, MENU, NAVIGATION arrows.
Display Indicators: Battery level, measurement mode, calibration status, data logging active.
Measurement Modes: CONTINUOUS, SINGLE, AVERAGE, PEAK HOLD. Settings: Display contrast, backlight timeout, auto-off timer, measurement units, date/time format. Calibration: Auto-calibration, manual calibration, calibration history.
USB: For data transfer and software updates. External probe: Additional measurement sensors.
Tip: Use certified USB cables only. Ensure proper driver installation on PC.
Supports multiple measurement modes for various applications.
WARNING! Do not exceed specified measurement ranges. Keep probe clean and free from debris.
Data Logging: Store up to 1000 measurements with timestamp. Data Export: USB transfer to PC software. Data Clear: Option to erase all stored measurements.
Power off before cleaning. Use soft, dry cloth for display and housing. Clean probe with approved cleaning solution only.
CAUTION! Do not immerse instrument in liquids. Avoid abrasive cleaners. Store in protective case when not in use.
FCC Part 15: Class A digital device; complies with interference limits for commercial use. CE marked for European compliance. RoHS compliant. Copyright © 2025 O.n Instruments; all rights reserved. For technical support, visit www.on-instruments.com or contact 1-800-555-0234.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Battery/connection | Charge battery; check power connections; ensure POWER button pressed. |
| Inaccurate readings | Calibration/probe | Perform calibration; clean probe; check for damage. |
| USB not recognized | Cable/drivers | Use certified cable; install proper drivers; check USB mode setting. |
| Data logging error | Memory full | Clear stored data; export existing data to PC. |
| Probe not responding | Connection/damage | Check probe connection; inspect for physical damage; replace if necessary. |
Reset: Menu > System > Factory Reset (erases all data and settings).
Service: 1-800-555-0234; www.on-instruments.com/support