Nurzviy SolarEpoch 100 User Manual

The Nurzviy SolarEpoch 100 is a 100W portable solar power station designed for off-grid energy solutions, featuring high-efficiency monocrystalline solar panels, a 100,000mAh lithium-ion battery, multiple output ports (AC, DC, USB), MPPT charge controller, LCD status display, overload protection, and weather-resistant construction. Ideal for camping, emergencies, and remote power needs. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Charging & Power Management 8. Safety Features 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Monocrystalline Solar Panel, Power Station Unit, Remote Control, AC Input/Output Ports, DC Output Ports, USB Ports, LCD Display.

FeatureDescription
Solar Panel InputFor connecting solar panels (max 100W)
AC Output PortFor powering AC devices (110V/60Hz)
DC Output PortsFor 12V/24V devices (cigarette lighter socket)
USB PortsFor charging phones, tablets, and small electronics
LCD DisplayShows battery level, input/output power, and status
MPPT ControllerMaximizes solar charging efficiency
Overload ProtectionAutomatically shuts off output if overloaded
Battery Management SystemProtects against overcharge, over-discharge, and short circuit
Carrying HandleFor easy portability
Weather-Resistant CaseIP54 rated for outdoor use

Installation

Unpack and inspect contents. Place on stable, flat surface.

  1. Position Solar Panel: Place in direct sunlight, facing the sun at optimal angle.
  2. Connect Solar Panel to Station: Use provided cable to connect panel to SOLAR INPUT port.
  3. Connect Devices: Plug devices into appropriate output ports (AC, DC, USB).
  4. Power On: Press and hold POWER button for 3 seconds to activate station.

WARNING! Do not expose to rain or submersion. Ensure all connections are secure before operation.

First-Time Setup

Power on station; follow LCD display prompts.

  1. Initial Charge: Fully charge battery via solar or AC adapter before first use.
  2. Set Language: In SETTINGS menu, select ENGLISH (default).
  3. Configure Output: Use MODE button to select output type (AC, DC, USB).
  4. Monitor Status: Check LCD for battery level and power flow.

CAUTION! Keep away from flammable materials and extreme temperatures.

Specifications

Controls and Settings

Access menu via LCD touch screen or remote control. Front Panel: POWER, MODE, SETTINGS, BACKLIGHT.

Remote: POWER, Numeric buttons, MODE, SETTINGS, VOLUME, MUTE, BACK, ENTER.

Output Settings: AC output voltage/frequency, DC output voltage, USB charging mode. System: Language (ENGLISH default), screen timeout, brightness, unit (C/F). Safety: Overload threshold, temperature cutoff, password protection (default 0000). Solar: MPPT mode, charging current limit.

Connecting Devices

Solar Panel: SOLAR INPUT port. AC Devices: AC OUTPUT port. DC Devices: DC OUTPUT port. USB Devices: USB ports.

  1. Turn off station and devices before connecting.
  2. Match device power requirements to station output capabilities.
  3. Select correct output mode via MODE button or touch screen.

Tip: Start with low-power devices to test functionality before connecting high-power appliances.

Charging & Power Management

Supports solar, AC wall adapter, and car charger input.

  1. Solar Charging: Connect panel, ensure direct sunlight, monitor LCD for input power.
  2. AC Charging: Use provided AC adapter, plug into wall outlet and AC INPUT port.
  3. Device Charging: Connect devices to appropriate ports, station automatically detects and delivers optimal power.
  4. Battery Save Mode: Enable in settings to extend battery life during low usage.
  5. Parallel Charging: Charge multiple devices simultaneously (total output not to exceed 300W).

WARNING! Do not exceed maximum input/output ratings. Disconnect during thunderstorms.

Safety Features

Overload Protection: Automatically cuts power if load exceeds 300W. Short Circuit Protection: Isolates output in case of short. Temperature Control: Reduces output or shuts down if overheated. Low Voltage Protection: Prevents battery damage by cutting off at 10% capacity.

Care & Cleaning

Power off and disconnect all cables before cleaning. Use slightly damp cloth for exterior; keep ports dry.

CAUTION! Do not use harsh chemicals or abrasives. Store in cool, dry place when not in use.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. Copyright © 2025 Nurzviy Technologies; trademarks of Nurzviy Solar Solutions, Inc. For support, visit www.nurzviysolar.com or contact 1-800-555-ENERGY.

Troubleshooting

SymptomPossible CauseCorrective Action
No power outputBattery depleted/overloadRecharge battery; reduce connected load; reset station.
Solar not chargingPoor sunlight/connectionsReposition panel for direct sun; check cable connections.
LCD display blankBattery low/backlight offCharge station; press BACKLIGHT button to activate display.
Overload warningConnected device exceeds ratingDisconnect high-power devices; restart station.
USB devices not chargingPort selection/cable issueEnsure correct output mode selected; try different cable.

Reset: Press and hold POWER + MODE for 10 seconds to factory reset.

Service: 1-800-555-ENERGY; www.nurzviysolar.com