The Novodes LoriSense Basic is a compact, entry-level environmental sensor unit designed for home and office use. It monitors temperature, humidity, and ambient light levels, featuring a simple LCD display, wireless connectivity via Bluetooth Low Energy (BLE), a built-in rechargeable battery, USB-C charging port, and a companion mobile app for data visualization and alerts. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting to Mobile App 7. Monitoring Data 8. Alerts & Notifications 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Integrated environmental sensors, LCD status display, Power/Mode button, Bluetooth pairing button, USB-C charging port, and wall-mount slot.

FeatureDescription
LCD DisplayShows current temperature, humidity, and light level
Temperature SensorMeasures ambient temperature from 0°C to 50°C
Humidity SensorMeasures relative humidity from 20% to 90% RH
Ambient Light SensorDetects light levels (Lux)
Bluetooth Low Energy (BLE)Wireless data sync to mobile app
USB-C PortFor charging and firmware updates
Power/Mode ButtonTurns unit on/off; cycles display modes
Bluetooth Pairing ButtonInitiates pairing with mobile device
Rechargeable BatteryLithium-ion, up to 30 days standby
Wall-Mount SlotFor optional mounting on wall or surface

Installation

Unpack and inspect contents. Choose a suitable location.

  1. Place the unit: Position on a flat, stable surface away from direct heat sources, vents, or moisture.
  2. Wall mounting (optional): Use the slot on the back with a suitable screw or adhesive mount.
  3. Initial power: Charge the unit via the provided USB-C cable before first use.

WARNING! Do not place in direct sunlight, near water, or in extreme temperatures. Ensure ventilation around the sensors.

First-Time Setup

Power on the unit; follow these steps for initial configuration.

  1. Charge the battery: Connect USB-C cable to a power source until the battery icon on the display is full.
  2. Power on: Press and hold the Power/Mode button for 3 seconds until the display lights up.
  3. Pair with mobile app: Download the "LoriSense" app from your device's app store. Press the Bluetooth Pairing button on the unit, then follow in-app instructions.
  4. Calibrate (optional): The app may guide you through a quick calibration for optimal accuracy.

CAUTION! Use only the provided or certified USB-C cable and charger. Do not disassemble the unit.

Specifications

Controls and Settings

Access settings via the physical buttons or the companion mobile app.

Unit Controls: Power/Mode Button (On/Off, cycle display), Bluetooth Pairing Button.

Display Modes: Cycle by pressing Power/Mode button briefly: Mode 1 (Temperature), Mode 2 (Humidity), Mode 3 (Light Level), Mode 4 (Battery Status).

Mobile App Settings: Data refresh interval, unit preferences (°C/°F), alert thresholds for each sensor, historical data view, firmware updates.

Connecting to Mobile App

The LoriSense app allows for detailed monitoring and configuration.

  1. Ensure Bluetooth is enabled on your mobile device.
  2. Open the LoriSense app and tap "Add Device".
  3. Press and hold the Bluetooth Pairing button on the unit for 5 seconds until the Bluetooth icon blinks.
  4. Select "LoriSense Basic-XXXX" from the app's device list.
  5. Follow on-screen prompts to complete pairing.

Tip: Keep the unit within 10 meters (33 feet) of your mobile device for a stable connection.

Monitoring Data

View data on the unit's display or in the mobile app.

  1. On-unit display: Use the Power/Mode button to cycle through real-time readings.
  2. In the app: View a consolidated dashboard with all sensor readings, updated at the set interval.
  3. Historical data: The app stores data locally (on your phone) for up to 30 days. View trends in graph form.
  4. Export data: Use the app's export feature to save data as a CSV file for external analysis.

WARNING! Sensor readings are for informational purposes only. Not intended for critical medical, industrial, or safety applications.

Alerts & Notifications

Set custom thresholds to receive alerts via the mobile app.

  1. Open the LoriSense app and go to 'Alerts' section.
  2. For each sensor (Temp, Humidity, Light), set a minimum and maximum value.
  3. Enable push notifications in your phone's settings for the LoriSense app.
  4. When a reading exceeds your set threshold, you will receive a notification.

Note: Alerts require the app to be running in the background and a Bluetooth connection to be active.

Care & Cleaning

Unplug charging cable before cleaning. Power off the unit if possible.

Use a soft, dry, lint-free cloth to gently wipe the exterior and the display. Do not use liquids, solvents, or abrasive cleaners. Ensure the sensor vents on the front are free of dust and obstructions.

CAUTION! Do not immerse in water or any liquid. Avoid contact with chemicals.

Regulatory Information

FCC ID: XXXX-XXXXX. This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. IC: XXXXX-XXXX. Contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada's licence-exempt RSS(s). Copyright © 2023 Novodes Inc. All rights reserved. LoriSense is a trademark of Novodes Inc. For support, visit www.novodes.com/support or contact [email protected].

Troubleshooting

SymptomPossible CauseCorrective Action
Unit does not power onBattery depletedConnect to USB-C charger for at least 30 minutes, then try again.
Display is blankUnit off or in sleep modePress Power/Mode button. If no response, charge the battery.
Cannot pair with appBluetooth disabled/out of rangeEnable Bluetooth on phone, ensure unit is within 3 feet during pairing, press pairing button again.
Inaccurate readingsSensor obstruction or placementMove unit away from heat/cold sources, ensure sensor vents are clean and unobstructed.
App not receiving dataBluetooth disconnectedBring phone closer to unit, restart the LoriSense app, restart Bluetooth on phone.
Battery drains quicklyHigh data refresh rate or old batteryIn app, increase data refresh interval (e.g., to 10 mins). If problem persists, battery may need replacement.

Reset: Press and hold Power/Mode and Pairing buttons together for 10 seconds to perform a factory reset (erases all pairings).

Service: [email protected]; www.novodes.com/support