Nds SFE Series User Manual

The Nds SFE Series is a professional-grade filtration system designed for commercial and industrial applications. It features advanced multi-stage filtration, high-flow capacity, durable construction, automated backwash cycles, pressure monitoring, and remote monitoring capabilities. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting System Components 7. Operating Procedures 8. Maintenance & Cleaning 9. Safety Features 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Multi-stage filter housing, Control Panel, Inlet/Outlet ports, Pressure Gauges, Backwash Valve, Drain connection, Remote Monitoring port.

FeatureDescription
Multi-stage FiltrationSediment, carbon, and fine filtration stages
High-Flow CapacityUp to 50 GPM flow rate
Automated BackwashProgrammable self-cleaning cycles
Pressure MonitoringInlet and outlet pressure gauges
Durable ConstructionStainless steel housing, corrosion-resistant
Control PanelLCD display with touch controls
Remote MonitoringEthernet/RS-485 connectivity for remote access
Safety Shut-offAutomatic shut-off on high pressure
Filter Status IndicatorsLED indicators for filter condition
Drain ValveFor backwash water discharge

Installation

Unpack and inspect all components. Install on level, stable surface.

  1. Position unit: Place in accessible location near water source and drain.
  2. Connect inlet/outlet: Use appropriate piping (copper, PVC, or PEX) with proper fittings.
  3. Connect drain line: Attach to drain valve for backwash discharge.
  4. Electrical connection: Connect to 120V AC power source with proper grounding.
  5. Pressure test: Check all connections for leaks before operation.

WARNING! System is heavy; use proper lifting equipment. Ensure all connections are secure and pressure-rated for system requirements.

First-Time Setup

Power on system; follow control panel prompts.

  1. Initialization: System will run self-test; check for error codes.
  2. Set date/time: Configure system clock for accurate maintenance scheduling.
  3. Program backwash cycle: Set frequency based on water quality (default: every 72 hours).
  4. Configure remote monitoring: Set up network parameters if using remote access.
  5. Calibrate pressure sensors: Follow on-screen calibration procedure.

CAUTION! Ensure water supply is turned off during initial setup. Verify drain line is properly connected before starting first backwash cycle.

Specifications

Controls and Settings

Access control menu via touch panel. Front Panel: POWER, MENU, BACK, ENTER, UP/DOWN arrows.

Control Functions: Power On/Off, Backwash Initiate, Manual Override, Settings Menu, Status Display.

Settings Menu: Backwash Schedule, Pressure Limits, Remote Access, Language (ENGLISH default), Units (PSI/GPM), Maintenance Alerts, System Reset. Operational Modes: Normal Filtration, Backwash Cycle, Bypass Mode, Manual Control.

Connecting System Components

Water Connections: Inlet, Outlet, Drain. Electrical: Power cord, Remote monitoring cable.

  1. Turn off main water supply before making connections.
  2. Install isolation valves on inlet and outlet for maintenance.
  3. Use thread seal tape on all pipe connections.
  4. Connect drain line with proper slope for gravity flow.
  5. For remote monitoring: Connect Ethernet cable to network port.

Tip: Install pressure relief valve if system pressure may exceed 150 PSI. Keep electrical connections away from water sources.

Operating Procedures

Normal operation maintains water filtration; backwash cleans filter media.

  1. Startup: Open inlet valve slowly, then outlet valve. Power on system.
  2. Monitor pressure: Check differential pressure (inlet vs outlet).
  3. Automatic backwash: System initiates based on schedule or pressure differential.
  4. Manual backwash: Press BACKWASH button on control panel when needed.
  5. Bypass mode: Use for system maintenance without interrupting water flow.
  6. Filter replacement: Initiate when system indicates or pressure differential exceeds 15 PSI.

WARNING! Do not open filter housing under pressure. Always shut off water supply and relieve pressure before maintenance.

Maintenance & Cleaning

Regular maintenance ensures optimal performance and longevity.

  1. Daily: Check pressure readings, inspect for leaks.
  2. Weekly: Verify backwash cycle completion, check drain line.
  3. Monthly: Inspect filter cartridges, clean pre-filter screen.
  4. Quarterly: Replace filter cartridges as needed, calibrate pressure sensors.
  5. Annually: Complete system inspection, replace O-rings and gaskets.

CAUTION! Use only manufacturer-approved replacement parts. Follow lock-out/tag-out procedures during maintenance.

Safety Features

High-pressure shut-off: Automatic at 150 PSI. Thermal protection: Prevents motor overheating. Leak detection: Optional sensor kit. Emergency stop: Manual override button. Ground fault protection: Built-in GFCI for electrical safety.

Regulatory Information

NSF/ANSI 61 certified for drinking water components. UL listed for electrical safety. Meets EPA water efficiency standards. FCC Part 15 Class A for digital device emissions. Copyright © 2023 Nds Filtration Systems; all trademarks property of Nds Corporation. For technical support, visit www.ndsfiltration.com or contact 1-800-555-NDSF (6373).

Troubleshooting

SymptomPossible CauseCorrective Action
No water flowClosed valves/clogged filterCheck all valves open; inspect and clean pre-filter.
High pressure differentialDirty filter mediaInitiate backwash cycle; replace filter if needed.
Backwash not initiatingSchedule setting/drain issueCheck backwash schedule; ensure drain line unobstructed.
Control panel errorPower/sensor issueCheck power connection; restart system; check sensor connections.
Water leakageLoose fittings/worn sealsTighten connections; replace O-rings or gaskets.
Unusual noiseAir in system/pump issueBleed air from system; check pump alignment and mounting.

Reset Procedure: Menu > System > Factory Reset (use caution - erases all settings).

Service Support: 1-800-555-NDSF (6373); www.ndsfiltration.com/support