The Multifit MULR Series is a versatile line of industrial-grade linear actuators designed for precise motion control in automation applications. Featuring robust construction, multiple stroke lengths, IP-rated protection, integrated limit switches, and compatibility with various control systems, the MULR Series offers reliable performance for positioning, lifting, and pushing tasks. Below are key sections covering safety, features, installation, operation, programming, maintenance, and troubleshooting.
Key components: High-torque DC motor, precision lead screw or belt drive, position feedback sensor, integrated control electronics, limit switches, mounting brackets, and connection ports.
| Feature | Description |
|---|---|
| Motor Type | Brushless DC motor with encoder feedback |
| Stroke Length | Multiple options from 50mm to 1000mm |
| Load Capacity | Up to 1500N dynamic, 4500N static |
| Protection Rating | IP65 standard (dust and water jet resistant) |
| Control Interface | RS-485, CANopen, analog voltage/pulse input |
| Limit Switches | Integrated mechanical and electronic end stops |
| Speed Range | 5-100mm/s adjustable |
| Position Accuracy | ±0.05mm repeatability |
| Power Supply | 24V DC ±10% |
| Operating Temperature | -10°C to +60°C |
Unpack and inspect contents. Ensure mounting surface is rigid and aligned.
WARNING! Actuator is heavy; use proper lifting equipment. Ensure all connections are secure before operation.
Power on actuator; initialize system via control interface.
CAUTION! Keep clear of moving parts during setup. Verify emergency stop functionality.
Access parameters via configuration software or teach pendant. Status Indicators: Power (green), Fault (red), Communication (yellow).
Control Inputs: Enable, Fault Reset, Home, Jog+, Jog-.
Configuration Parameters: Operating mode, max speed, acceleration/deceleration, current limit, homing method, soft limits, communication address, baud rate. Status Monitoring: Position, velocity, current, temperature, error codes.
Power: 24V DC supply. Control: PLC, motion controller, or PC via RS-485/CANopen. I/O: External sensors, emergency stop, enable signals.
Tip: Ensure power supply is adequately rated for peak current demand.
Supports position, velocity, torque, and homing modes.
WARNING! Do not exceed rated load or speed. Monitor temperature during continuous operation.
Use Multifit Motion Suite software or third-party PLC with appropriate protocol. Parameter Backup: Save configuration to file. Teach Points: Record positions via teach pendant. Sequence Programming: Create multi-step motion sequences.
Disconnect power before maintenance. Regularly inspect for wear, clean exterior with dry cloth, lubricate rod per schedule (if applicable).
CAUTION! Do not use solvents or high-pressure sprays. Replace seals if damaged.
EMC Directive 2014/30/EU: Complies with emission and immunity standards. Machinery Directive 2006/42/EC: For integration into machinery. Copyright © 2025 Multifit Automation; trademarks of Multifit GmbH. For support, visit www.multifit-automation.com or contact +49 (0)30 12345678.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Actuator does not move | Power/Enable signal | Check 24V supply; verify Enable input is active; inspect fuses. |
| Erratic motion | Load/parameters | Reduce load; check acceleration settings; verify mechanical alignment. |
| Communication failure | Cabling/address | Verify cable connections and termination; check device address and baud rate. |
| Over temperature fault | Duty cycle/cooling | Reduce duty cycle; ensure ambient temperature within spec; check for obstruction. |
| Limit switch error | Wiring/alignment | Check limit switch wiring; verify switch activation alignment. |
Reset: Power cycle or send fault reset command.
Service: +49 (0)30 12345678; www.multifit-automation.com