Multifit MULR Series User Manual

The Multifit MULR Series is a versatile line of industrial-grade linear actuators designed for precise motion control in automation applications. Featuring robust construction, multiple stroke lengths, IP-rated protection, integrated limit switches, and compatibility with various control systems, the MULR Series offers reliable performance for positioning, lifting, and pushing tasks. Below are key sections covering safety, features, installation, operation, programming, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operation Modes 8. Programming & Configuration 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: High-torque DC motor, precision lead screw or belt drive, position feedback sensor, integrated control electronics, limit switches, mounting brackets, and connection ports.

FeatureDescription
Motor TypeBrushless DC motor with encoder feedback
Stroke LengthMultiple options from 50mm to 1000mm
Load CapacityUp to 1500N dynamic, 4500N static
Protection RatingIP65 standard (dust and water jet resistant)
Control InterfaceRS-485, CANopen, analog voltage/pulse input
Limit SwitchesIntegrated mechanical and electronic end stops
Speed Range5-100mm/s adjustable
Position Accuracy±0.05mm repeatability
Power Supply24V DC ±10%
Operating Temperature-10°C to +60°C

Installation

Unpack and inspect contents. Ensure mounting surface is rigid and aligned.

  1. Mounting: Secure actuator using provided brackets and fasteners. Ensure parallel alignment to load path.
  2. Electrical Connection: Connect 24V DC power to terminals (V+, V-). Observe polarity.
  3. Control Wiring: Connect communication cables (RS-485/CANopen) or analog/pulse wires as required.
  4. Mechanical Connection: Attach load to actuator rod end using appropriate coupling.
  5. Power On: Apply power and verify LED status indicator.

WARNING! Actuator is heavy; use proper lifting equipment. Ensure all connections are secure before operation.

First-Time Setup

Power on actuator; initialize system via control interface.

  1. Homing Procedure: Execute homing routine to establish reference position.
  2. Parameter Configuration: Set operating mode, speed, acceleration, and current limits via software.
  3. Limit Switch Test: Manually jog to verify mechanical and electronic limit functionality.
  4. Load Test: Run actuator through full stroke with no load, then with intended load.

CAUTION! Keep clear of moving parts during setup. Verify emergency stop functionality.

Specifications

Controls and Settings

Access parameters via configuration software or teach pendant. Status Indicators: Power (green), Fault (red), Communication (yellow).

Control Inputs: Enable, Fault Reset, Home, Jog+, Jog-.

Configuration Parameters: Operating mode, max speed, acceleration/deceleration, current limit, homing method, soft limits, communication address, baud rate. Status Monitoring: Position, velocity, current, temperature, error codes.

Connecting Devices

Power: 24V DC supply. Control: PLC, motion controller, or PC via RS-485/CANopen. I/O: External sensors, emergency stop, enable signals.

  1. Turn off power before making connections.
  2. Use shielded cables for communication lines; ground shield at one end.
  3. Connect I/O signals according to wiring diagram (sourcing/sinking).
  4. Select communication protocol and address via DIP switches or software.

Tip: Ensure power supply is adequately rated for peak current demand.

Operation Modes

Supports position, velocity, torque, and homing modes.

  1. Position Mode: Move to absolute or relative target position.
  2. Velocity Mode: Run at specified speed until stop command.
  3. Torque Mode: Apply constant force (current limited).
  4. Homing: Seek reference switch to establish zero position.
  5. Jogging: Manual movement via buttons or software.
  6. Profile Motion: Predefined move profiles with trapezoidal or S-curve acceleration.
  7. Gearing: Electronic gearing to master encoder input.
  8. Position Capture: Latch position on external trigger input.

WARNING! Do not exceed rated load or speed. Monitor temperature during continuous operation.

Programming & Configuration

Use Multifit Motion Suite software or third-party PLC with appropriate protocol. Parameter Backup: Save configuration to file. Teach Points: Record positions via teach pendant. Sequence Programming: Create multi-step motion sequences.

Care & Maintenance

Disconnect power before maintenance. Regularly inspect for wear, clean exterior with dry cloth, lubricate rod per schedule (if applicable).

CAUTION! Do not use solvents or high-pressure sprays. Replace seals if damaged.

Regulatory Information

EMC Directive 2014/30/EU: Complies with emission and immunity standards. Machinery Directive 2006/42/EC: For integration into machinery. Copyright © 2025 Multifit Automation; trademarks of Multifit GmbH. For support, visit www.multifit-automation.com or contact +49 (0)30 12345678.

Troubleshooting

SymptomPossible CauseCorrective Action
Actuator does not movePower/Enable signalCheck 24V supply; verify Enable input is active; inspect fuses.
Erratic motionLoad/parametersReduce load; check acceleration settings; verify mechanical alignment.
Communication failureCabling/addressVerify cable connections and termination; check device address and baud rate.
Over temperature faultDuty cycle/coolingReduce duty cycle; ensure ambient temperature within spec; check for obstruction.
Limit switch errorWiring/alignmentCheck limit switch wiring; verify switch activation alignment.

Reset: Power cycle or send fault reset command.

Service: +49 (0)30 12345678; www.multifit-automation.com