Manta RDI916 SOLAR User Manual

The Manta RDI916 SOLAR is a 9.16-inch Solar-Powered Digital Inverter Display with integrated solar charging, high-brightness LCD screen, built-in battery management system, real-time power monitoring, multiple output modes (AC/DC), overload protection, temperature compensation, and wireless connectivity for remote monitoring. Powered by solar input (12-24V) with battery backup. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Solar Charging Operation 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Solar charging controller, LCD display panel, Battery terminals, AC/DC output ports, Wireless module, Temperature sensor.

FeatureDescription
Solar InputFor connecting solar panels (12-24V DC)
Battery TerminalsFor connecting backup battery system
AC Output PortFor AC power output (110V/220V selectable)
DC Output PortFor DC power output (12V/24V)
LCD DisplayShows power metrics, battery status, and system alerts
Wireless ModuleEnables remote monitoring via mobile app
POWER ButtonTurns system on/off
MODE SelectorSwitches between AC/DC output modes
RESET ButtonResets system to factory defaults
ALARM MuteSilences system alerts

Installation

Unpack and inspect contents. Mount in dry, ventilated location.

  1. Connect solar panels: Attach positive/negative cables to solar input terminals.
  2. Connect battery: Attach battery cables to battery terminals (observe polarity).
  3. Connect loads: Attach devices to AC or DC output ports as needed.
  4. Secure mounting: Use provided brackets to mount unit securely.

WARNING! Ensure all power sources are disconnected during installation. Use proper protective equipment.

First-Time Setup

Power on system; follow display prompts.

  1. Initialize system: Press POWER button to start initialization sequence.
  2. Configure settings: Use MODE button to select output voltage (110V/220V).
  3. Set battery type: In SYSTEM menu, select battery type (Gel, AGM, Lithium).
  4. Connect wireless: Download app and pair device via Bluetooth/Wi-Fi.

CAUTION! Ensure proper ventilation around unit. Do not install in direct sunlight.

Specifications

Controls and Settings

Access menu via front panel buttons. Front Panel: POWER, MODE, RESET, ALARM MUTE.

Display Interface: Shows battery status, solar input, output power, system temperature.

System Settings: Battery type selection, output voltage, charging parameters, wireless setup. Protection Settings: Overload threshold, temperature limits, low-voltage cutoff. Monitoring: Historical data logging, real-time graphs, alert history.

Connecting Devices

Solar Panels: Solar input terminals. Battery: Battery terminals. Loads: AC/DC output ports.

  1. Turn off all power sources before connecting.
  2. Connect solar panels first, then battery, then loads.
  3. Verify polarity on all connections.
  4. Secure all cable connections tightly.

Tip: Use appropriate cable gauges for current requirements. Keep cables organized.

Solar Charging Operation

Automatic solar charging with MPPT technology.

  1. Charging stages: Bulk, Absorption, Float, Equalization (selectable).
  2. Monitoring: View charging current, voltage, and power on display.
  3. Battery protection: Automatic cutoff at low voltage; temperature compensation.
  4. Load management: Priority to solar power, then battery backup.
  5. Data logging: Track daily energy production and consumption.
  6. Remote control: Adjust settings via mobile app when connected.
  7. Fault alerts: Visual and audible alarms for system faults.
  8. Sleep mode: Energy saving mode during low solar input.

WARNING! Do not disconnect battery while solar panels are producing power. Follow proper shutdown procedure.

Safety Features

Overload Protection: Automatically cuts output if overload detected. Short Circuit Protection: Immediate shutdown on short circuit. Temperature Protection: Reduces charging current at high temperatures. Reverse Polarity Protection: Prevents damage from incorrect connections.

Care & Maintenance

Regular inspection recommended. Keep unit clean and dry.

  1. Monthly: Check all cable connections for tightness.
  2. Quarterly: Clean exterior with dry cloth; check ventilation.
  3. Annually: Verify calibration of voltage/current readings.
  4. Battery: Monitor battery health per manufacturer recommendations.

CAUTION! Do not use water or cleaning solutions. Disconnect all power before maintenance.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits. CE certified for European market. RoHS compliant. Copyright © 2025 Manta Solar Technologies; all rights reserved. For support, visit www.mantasolar.com or contact 1-800-555-0916.

Troubleshooting

SymptomPossible CauseCorrective Action
No display powerBattery/solar connectionCheck battery connections; verify solar panel output.
No chargingSolar panel issuesCheck panel connections; verify sunlight exposure; check fuses.
Overload alarmExcessive loadReduce connected load; check for short circuits.
Wireless not connectingDistance/interferenceMove closer to unit; check Bluetooth/Wi-Fi settings.
Inaccurate readingsCalibration neededPerform calibration procedure in service menu.

Reset: Hold RESET button for 10 seconds to factory reset.

Service: 1-800-555-0916; www.mantasolar.com/support