Logia LOWSC713SWB User Manual

The Logia LOWSC713SWB is a 7-inch Portable Solar Generator with a 155Wh capacity, featuring a pure sine wave inverter, multiple output ports (AC, DC, USB), a built-in MPPT solar charge controller, LCD display for system status, and a rugged, weather-resistant design. Ideal for camping, emergencies, and outdoor power needs. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Solar Charging 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Lithium-ion battery pack, Pure Sine Wave Inverter, MPPT Solar Charge Controller, LCD Display, AC outlets, DC car port, USB ports, Solar Input port.

FeatureDescription
AC Output2 x 110V AC outlets (300W continuous, 600W surge)
DC Output1 x 12V DC car port
USB Ports2 x USB-A (5V/2.4A), 1 x USB-C (PD 60W)
Solar InputSupports up to 100W solar panel (MC4 connector)
LCD DisplayShows battery level, input/output power, warnings
Pure Sine WaveClean power for sensitive electronics
MPPT ControllerMaximizes solar charging efficiency
Battery Capacity155Wh Lithium-ion
WeightApprox. 3.5 lbs (1.6 kg)
Built-in HandleFor easy portability

Installation

Unpack and inspect contents. Place on stable, dry surface.

  1. Initial Charge: Connect to AC wall outlet using included adapter to fully charge unit before first use.
  2. Solar Panel Connection: Connect compatible solar panel to SOLAR INPUT port using MC4 cables.
  3. Device Connection: Plug devices into appropriate output ports (AC, DC, USB).
  4. Power On: Press and hold POWER button for 3 seconds to activate unit.

WARNING! Keep unit away from water, heat sources, and flammable materials. Do not disassemble.

First-Time Setup

Power on unit; monitor LCD display.

  1. Charge Battery: Ensure battery is fully charged via AC or solar before extended use.
  2. Configure Settings: Use MODE button to cycle through output settings (ECO, Standard).
  3. Monitor Display: Check battery level, input/output wattage on LCD screen.
  4. Test Outputs: Connect a small device to each port to verify functionality.

CAUTION! Use only included or manufacturer-approved cables and solar panels.

Specifications

Controls and Settings

Front Panel: POWER button, MODE button, LCD display, output ports.

LCD Icons: Battery level, AC/DC/USB output status, solar input, overload warning, low battery warning.

Modes: ECO (auto power-off when device is fully charged or not in use), Standard (continuous output). Settings: Press MODE to toggle between output modes. Display: Shows real-time input/output power, estimated runtime.

Connecting Devices

AC Devices: Plug into AC outlets (max 300W total). DC Devices: Use 12V car port. USB Devices: Connect to USB-A or USB-C ports.

  1. Check device power requirements (watts/amps) before connecting.
  2. Ensure total connected load does not exceed 300W for AC outlets.
  3. For solar charging, connect panel to SOLAR INPUT in adequate sunlight.

Tip: Start with the highest power device first to avoid overload.

Solar Charging

Supports 100W solar panel input via MPPT controller.

  1. Panel Setup: Position solar panel in direct sunlight, facing the sun.
  2. Connection: Use MC4 cables to connect panel to SOLAR INPUT port.
  3. Monitoring: LCD will show solar input wattage and charging status.
  4. Efficiency: MPPT controller optimizes charging even in low-light conditions.
  5. Charging Time: Approx. 3-5 hours with 100W panel under ideal conditions.

WARNING! Do not connect solar panel while unit is powering devices. Ensure correct polarity.

Safety Features

Overload Protection: Automatically shuts off output if exceeded. Short Circuit Protection: Safeguards against DC/USB shorts. Over-temperature Protection: Reduces output if overheating. Low Battery Protection: Shuts down at 10% to prevent battery damage.

Care & Maintenance

Store in cool, dry place. Clean with dry cloth; do not use liquids. Periodically charge to 50% if storing long-term.

CAUTION! Do not expose to rain or extreme temperatures. Avoid dropping or impact.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits. UL Certified: Meets safety standards for portable power stations. Copyright © 2025 Logia; trademarks of Logia Inc. For support, visit www.logia.com or contact 1-800-555-1234.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit won't power onBattery depletedCharge via AC or solar for at least 30 minutes.
No output from portsOverload/tripDisconnect devices, wait 30 seconds, restart unit.
Solar not chargingPanel/connectionEnsure panel in sun, cables securely connected, correct port.
LCD shows error codeFault conditionRefer to manual error code list; reset unit if needed.
Reduced runtimeBattery age/high loadReduce connected load; consider battery replacement if old.

Reset: Hold POWER + MODE for 10 seconds to hard reset.

Service: 1-800-555-1234; www.logia.com/support

Logia LOWSC713SWB User Manual © - All Rights Reserved 2025