The Larson Electronics SPLED-STL-600W-12V-M1 is a 600-watt, 12-volt DC LED light fixture designed for marine, industrial, and off-grid applications. It features a durable stainless steel housing, IP68 waterproof rating, high-efficiency LED chips, wide voltage input range, and multiple mounting options. Below are key sections for safety, features, installation, wiring, operation, maintenance, and troubleshooting.
Key components: High-output LED array, Stainless Steel Housing, Waterproof Gasket, Mounting Brackets, Wiring Terminal Block.
| Feature | Description |
|---|---|
| Power Rating | 600 Watts @ 12V DC |
| Housing Material | 316 Stainless Steel (Marine Grade) |
| Ingress Protection | IP68 (Submersible) |
| Voltage Range | 10V - 30V DC |
| Beam Angle | 120 Degrees |
| Luminous Flux | 72,000 Lumens |
| Color Temperature | 5000K (Daylight White) |
| Operating Temp | -40°C to +60°C |
| Mounting | Bracket, Pole, or Surface Mount |
| Wiring | Terminal Block (Positive/Negative/Ground) |
Unpack and inspect contents. Ensure mounting surface is stable and can support fixture weight.
WARNING! Fixture is heavy; use proper lifting techniques or two-person lift. Ensure power is disconnected before installation.
After physical installation, proceed with electrical connection and verification.
CAUTION! Use only copper wiring of appropriate gauge (recommended 6 AWG for runs under 20 feet). Ensure all connections are weatherproof.
This fixture has no user controls on the housing. Operation is controlled by the connected power source (switch, relay, controller).
Terminal Block Connections:
External Control Options: Can be connected to timers, photocells, motion sensors, or DMX controllers via the power line using appropriate switching devices.
Basic connection for direct DC power.
Tip: Use dielectric grease on terminal connections in marine environments to prevent corrosion.
Designed for continuous operation in harsh environments.
WARNING! Do not look directly at the LED light source. Do not operate with damaged lens or housing. Ensure fixture is properly grounded.
Disconnect power before any maintenance.
CAUTION! Do not open the LED compartment. No user-serviceable parts inside. Tampering voids warranty.
This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. CE marked indicating conformity with health, safety, and environmental protection standards for products sold within the European Economic Area. RoHS compliant. Copyright © Larson Electronics. For technical support, visit www.larsonelectronics.com or contact 1-800-369-6671.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Fixture does not turn on | No power / Incorrect wiring | Check power source voltage (12V). Verify polarity and secure connections at terminal block. |
| Dim or flickering light | Low voltage / Loose connection | Measure voltage at fixture terminals under load. Tighten all wire connections. Check for voltage drop in wiring. |
| Fixture overheats and dims | Insufficient ventilation / High ambient temp | Ensure fixture has adequate air flow. Do not enclose. Allow to cool; it will resume normal operation. |
| Water inside housing | Damaged seal / Loose gland nut | Disconnect power immediately. Inspect and replace cable gland or main gasket. Ensure compartment is closed tightly. |
| Partial LEDs dark | LED or driver failure | Contact Larson Electronics support. Do not attempt to repair internally. |
Reset: Cycle power off for 30 seconds, then back on.
Service: 1-800-369-6671; www.larsonelectronics.com