Fvc UN0108B Installation Manual

The Fvc UN0108B is a high-performance network video encoder designed for professional surveillance applications. It converts analog video signals into digital format for transmission over IP networks, supporting H.264 compression, remote management, and integration with various VMS platforms. Below are key sections for safety, features, installation, configuration, operation, and troubleshooting.

1. Features at a Glance 2. Package Contents 3. Hardware Installation 4. Specifications 5. Front/Rear Panel Controls 6. Network Configuration 7. Web Interface Setup 8. Video & Audio Settings 9. Maintenance & Care 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Main unit, Power adapter, Mounting brackets, Quick start guide.

FeatureDescription
Video Input1-channel BNC composite video input
CompressionH.264 Main Profile, supports dual-stream
ResolutionUp to 1080p/30fps
Network Interface10/100/1000 Mbps Ethernet (RJ-45)
Audio Support1-channel audio input (RCA), 1-channel output
Alarm I/O2 inputs, 1 output (dry contact)
Power Supply12V DC, 1.5A
Operating Temp-10°C to 50°C (14°F to 122°F)
ProtocolsTCP/IP, HTTP, HTTPS, RTSP, ONVIF
ManagementWeb browser, CMS software

Package Contents

Unpack and verify all items are present.

  1. Fvc UN0108B Video Encoder Unit (1 pc)
  2. 12V DC Power Adapter (1 pc)
  3. Mounting Bracket Kit (1 set)
  4. Quick Installation Guide (1 pc)
  5. Screws and Anchors (1 pack)

WARNING! Do not use if any item is damaged or missing. Contact supplier immediately.

Hardware Installation

Mount the encoder in a well-ventilated area.

  1. Mounting: Use brackets to attach to wall or DIN rail.
  2. Video Connection: Connect analog camera to VIDEO IN (BNC).
  3. Audio Connection: Connect microphone to AUDIO IN (RCA).
  4. Network Connection: Connect Ethernet cable to RJ-45 port.
  5. Power Connection: Connect 12V DC adapter to power port.
  6. Alarm I/O: Connect sensors to ALARM IN and outputs to ALARM OUT.

CAUTION! Ensure proper grounding. Use only provided power adapter.

Specifications

Front/Rear Panel Controls

Front Panel: POWER LED (green), STATUS LED (amber), NETWORK LED (green).

Rear Panel: VIDEO IN (BNC), AUDIO IN (RCA), AUDIO OUT (RCA), ALARM IN (2 terminals), ALARM OUT (1 terminal), ETHERNET (RJ-45), DC 12V POWER, GND terminal.

LED Indicators: POWER (steady on = powered), STATUS (blinking = working, steady = error), NETWORK (blinking = data activity).

Network Configuration

Default IP: 192.168.1.108. Connect directly or via network switch.

  1. Connect PC to same network as encoder.
  2. Set PC IP to same subnet (e.g., 192.168.1.x).
  3. Open web browser, enter encoder IP address.
  4. Login with default credentials (admin/admin).
  5. Configure network settings (IP, gateway, DNS).

Tip: Use the configuration tool (provided on CD) to discover device on network.

Web Interface Setup

Access all settings via web browser.

  1. Login: Enter username and password.
  2. System: Set time, date, device name, user management.
  3. Network: Configure IP, port, PPPoE, DDNS.
  4. Video: Set resolution, frame rate, bit rate, codec.
  5. Audio: Enable/disable, select codec, adjust volume.
  6. Event: Configure motion detection, alarm triggers.
  7. Storage: Set up recording schedule, NAS backup.
  8. Save settings and reboot if prompted.

WARNING! Change default password immediately. Keep firmware updated.

Video & Audio Settings

Optimize video quality for your application.

Video Settings: Resolution (1080p/720p/D1), Frame Rate (1-30 fps), Bit Rate Control (CBR/VBR), Quality (1-6), Mirror/Flip.

Audio Settings: Input Gain, Output Volume, Noise Reduction, Codec Selection.

Stream Settings: Primary Stream (high quality), Secondary Stream (low bandwidth), RTSP port (554 default).

Maintenance & Care

Unplug power before maintenance. Clean with dry, soft cloth.

CAUTION! Do not open casing. No user-serviceable parts inside. Avoid exposure to water, dust, extreme temperatures.

Regulatory Information

FCC Part 15 Class B: Complies with limits for digital devices. CE marked. RoHS compliant. Copyright © Fvc Technologies. For technical support, visit www.fvc.com/support or contact +1-800-555-0199.

Troubleshooting

SymptomPossible CauseCorrective Action
No powerAdapter/connectionCheck power adapter connection; verify outlet; try different adapter.
No videoCamera/cable/settingsCheck camera power; replace BNC cable; verify video settings in web interface.
Cannot access web interfaceNetwork/IPVerify PC and encoder are in same subnet; disable firewall temporarily; ping device IP.
Poor video qualityBandwidth/settingsIncrease bit rate; lower resolution; check network congestion.
No audioCable/configurationCheck audio cable connection; enable audio in settings; adjust volume.
Device not discoveredNetwork/toolRun configuration tool as administrator; check antivirus blocking.

Reset to Default: Press and hold reset button (inside pinhole) for 10 seconds.