Feit Electric PANEL Use And Care Manual

The Feit Electric PANEL is a modern LED panel light designed for energy-efficient, uniform illumination in residential and commercial spaces. It features a slim profile, high color rendering index (CRI), multiple color temperatures, dimmable options (where applicable), and easy installation for drop ceiling grids or surface mounting. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Installation Instructions 4. Specifications 5. Operation & Controls 6. Mounting Options 7. Dimming Compatibility 8. Maintenance & Cleaning 9. Regulatory & Compliance 10. Troubleshooting

Features at a Glance

Key components: LED panel module, mounting brackets/suspension kit, driver/power supply, installation hardware.

FeatureDescription
LED TechnologyEnergy-efficient, long-life LEDs with uniform light distribution
Color TemperatureSelectable or fixed (e.g., 3000K Warm White, 4000K Neutral, 5000K Daylight)
DimmableCompatible with standard phase-cut dimmers (if model specified)
CRI (Color Rendering Index)80+ or 90+ for accurate color representation
InstallationDesigned for drop ceiling (2'x2' or 2'x4') or surface mount
Beam AngleWide, even illumination (typically 120°)
Input Voltage120V AC, 50/60Hz
WarrantyLimited warranty as specified (e.g., 5 years)
CertificationsUL Listed, Energy Star qualified (if applicable)
IP RatingDamp or dry location rated (as per model)

Safety Information

Read all instructions before installation and use.

  1. Turn off power at circuit breaker before installation or maintenance.
  2. Ensure electrical supply matches fixture rating (120V AC).
  3. Use only with compatible mounting systems and dimmers (if dimmable).
  4. Do not install in enclosed fixtures unless rated for such use.
  5. Keep away from flammable materials and heat sources.

WARNING! Risk of electric shock. Installation should be performed by a qualified electrician in accordance with local codes.

Installation Instructions

For drop ceiling (2'x2' or 2'x4' grid) installation:

  1. Turn off power at breaker and verify it is off.
  2. Remove ceiling tile from grid where panel will be installed.
  3. Attach mounting brackets to panel (if required) using provided screws.
  4. Connect AC wires: Black (line) to black, White (neutral) to white, Green/Yellow (ground) to green.
  5. Secure panel into ceiling grid; ensure it is level and firmly seated.
  6. Restore power and test operation.

Surface Mount: Use mounting kit to attach directly to ceiling junction box.

CAUTION! Do not overtighten screws. Do not support fixture by its wires.

Specifications

Operation & Controls

Power on via wall switch. For dimmable models, use compatible dimmer switch.

Color Temperature Selection (if applicable): Some models have a switch on the driver or panel edge to select 3000K/4000K/5000K.

Dimming: Use listed compatible dimmer. If flickering occurs, adjust trim or replace with recommended dimmer.

Note: Non-dimmable models must not be connected to dimmer circuits.

Mounting Options

Drop Ceiling: Fits standard T-bar grid. Surface Mount: Use included kit to attach to flat surface.

  1. Ensure mounting surface can support fixture weight.
  2. Follow included diagram for bracket placement.
  3. For suspended mounting, use appropriate suspension cables (sold separately).

Tip: Verify grid size before installation (2'x2' or 2'x4').

Dimming Compatibility

If your PANEL model is dimmable, it is compatible with specific dimmer types.

  1. Check packaging or label for dimming type (e.g., TRIAC, 0-10V, ELV).
  2. Use only dimmers listed in compatibility guide (available at feit.com).
  3. If dimming range is limited or flickering occurs, adjust dimmer trim or try a different compatible model.
  4. For multiple panels on one dimmer, ensure total load is within dimmer rating.

WARNING! Using non-compatible dimmers may cause damage, flicker, or reduced lifespan.

Maintenance & Cleaning

Turn off power and allow to cool before cleaning.

  1. Use soft, dry cloth to wipe dust from panel surface.
  2. For stubborn dirt, use mild soap solution on damp cloth; do not spray directly.
  3. Dry thoroughly before restoring power.
  4. Do not use abrasive cleaners or solvents.

CAUTION! Do not disassemble fixture. No user-serviceable parts inside.

Regulatory & Compliance

UL Listed for safety in the United States and Canada. Complies with FCC Part 15 for electromagnetic interference. Energy Star qualified models meet efficiency standards. This product may be covered by limited warranty—see packaging or website for details. For support, visit www.feit.com or contact 1-866-326-7883.

Troubleshooting

SymptomPossible CauseCorrective Action
Light does not turn onPower off / wiringCheck breaker; ensure switch is on; verify wiring connections.
FlickeringDimmer incompatible / loose connectionUse compatible dimmer; check wires are secure.
Dimming not smoothDimmer load / trim settingEnsure total load is within dimmer range; adjust dimmer trim.
Uneven brightnessDriver issue / agingContact support; may require replacement.
Buzzing/hummingDimmer / electronic interferenceTry different compatible dimmer; ensure proper grounding.

Reset: Turn power off for 30 seconds, then restore.

Service: 1-866-326-7883; www.feit.com

Feit Electric PANEL Use And Care Manual © - All Rights Reserved 2025