The Evosanitary 15WG15-15 is a 15-inch Wall-Mounted Germicidal UV-C Light Fixture designed for surface and air disinfection in healthcare, commercial, and institutional settings. It features a 15-watt UV-C lamp, a durable metal housing with a protective grille, a built-in motion sensor for safety, a programmable timer, wall-mount brackets, and a remote control for operation. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: UV-C Germicidal Lamp, Metal Housing with Protective Grille, Motion Sensor, Timer Control Unit, Remote Control, Wall-Mount Brackets.
| Feature | Description |
|---|---|
| UV-C Lamp | 15-watt germicidal lamp for effective disinfection |
| Motion Sensor | Automatically turns off UV-C when motion is detected for safety |
| Programmable Timer | Set automatic on/off cycles (1-240 minutes) |
| Remote Control | Wireless operation from a distance |
| Wall-Mount Brackets | For secure mounting on walls or ceilings |
| Protective Grille | Prevents direct contact with the lamp |
| Power Indicator LED | Shows operational status |
| Manual Override Switch | For direct control at the unit |
| Safety Lock | Prevents unauthorized operation |
| AC Power Input | For 120V AC, 60Hz connection |
Unpack and inspect contents. Ensure mounting location is suitable.
WARNING! UV-C radiation is harmful to eyes and skin. Never look directly at the lamp when it is on. Ensure the area is unoccupied during installation and setup.
After installation, configure the unit before first use.
CAUTION! Always verify the motion sensor is functioning correctly before leaving the unit in automatic mode. Perform a visual check without looking directly at the lamp.
Access controls via Remote Control or Manual Override Switch on the unit.
Remote Control: POWER ON/OFF, TIMER SET (+/-), MOTION SENSOR ON/OFF, SAFETY LOCK, SYNC, MANUAL OVERRIDE.
Manual Controls (on unit): Power Switch, Timer Dial, Motion Sensor Bypass Button, Status LED.
Timer Settings: Set duration for automatic shut-off. Use remote or dial to select minutes.
Motion Sensor Settings: Enable/disable via remote. When enabled, UV-C turns off if motion is detected within 10 feet.
Safety Lock: Prevents operation without remote authorization. Default code: 0000 (change via remote).
Motion Sensor: Primary safety feature; deactivates UV-C upon detecting movement.
Safety Lock: Requires code to operate, preventing unauthorized use.
Protective Grille: Physical barrier between user and UV-C lamp.
Status Indicators: LED shows power and operational mode.
Automatic Shut-off: Timer ensures unit does not run indefinitely.
IMPORTANT: These safety features do not replace proper operational procedures. Always ensure the area is vacant before activating the UV-C lamp.
Standard operation for disinfection cycles.
WARNING! Never bypass the motion sensor for occupied spaces. UV-C exposure causes severe eye and skin damage.
Regular maintenance ensures optimal performance and safety.
Cleaning: Unplug unit. Wipe exterior with a dry, soft cloth. Do not use liquids or cleaners on the grille or lamp.
Lamp Replacement (every 9000 hours or ~1 year of typical use):
CAUTION! Handle UV-C lamps with gloves to avoid skin oils reducing effectiveness. Dispose of old lamps according to local regulations for mercury-containing bulbs.
This device complies with FCC Part 15 Class B for unintentional radiators. It meets UL 8800 standards for germicidal equipment. UV-C lamps are regulated by the FDA (21 CFR 1040.20). Copyright © 2023 Evosanitary; trademarks of EvoHealth Technologies, Inc. For support, visit www.evosanitary.com or contact 1-800-555-HELP (4357).
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Unit will not power on | No power / Safety lock engaged | Check outlet and plug; ensure safety lock is disengaged with correct code. |
| UV-C lamp does not illuminate | Lamp failure / Timer not set | Replace lamp; ensure timer is set to a duration greater than zero. |
| Motion sensor not working | Obstructed sensor / Settings | Clean sensor lens; ensure motion sensor is enabled in settings. |
| Remote control not responding | Batteries / Sync lost | Replace batteries; re-sync remote to unit (press SYNC for 3 seconds). |
| Unit turns off unexpectedly | Motion detected / Timer expired | This is normal safety operation; ensure area is vacant and reset timer if needed. |
| Unusual noise or smell | Electrical issue / Overheating | Immediately unplug unit and contact technical support. Do not use. |
Reset: Unplug unit for 60 seconds to reset control board.
Service: 1-800-555-HELP (4357); www.evosanitary.com/support