The Eco-Worthy 12 is a 12-volt solar power system designed for off-grid applications, featuring a high-efficiency monocrystalline solar panel, PWM charge controller, deep-cycle battery, power inverter, and comprehensive wiring kit. Below are key sections for safety, features, installation, setup, operation, maintenance, and troubleshooting.
Key components: Monocrystalline Solar Panel, PWM Charge Controller, Deep-Cycle Battery, Power Inverter, Wiring Kit with Connectors.
| Feature | Description |
|---|---|
| Solar Panel | 100W monocrystalline with high conversion efficiency |
| Charge Controller | PWM type with LCD display for monitoring |
| Deep-Cycle Battery | 12V 100Ah sealed lead-acid battery |
| Power Inverter | 300W pure sine wave output |
| Wiring Kit | Includes cables, connectors, and mounting hardware |
| LCD Display | Shows battery voltage, charging current, and load status |
| Overload Protection | Automatic shutdown on excessive load |
| Short-Circuit Protection | Built-in protection for all components |
| Low Voltage Disconnect | Prevents battery over-discharge |
| USB Output | 5V/2.1A USB port for charging devices |
Unpack and inspect all components. Choose a suitable location with maximum sunlight exposure.
WARNING! Install in dry location away from flammable materials. Use proper personal protective equipment during installation.
After installation, power on system and configure settings.
CAUTION! Never connect solar panel directly to battery without charge controller. Ensure all connections are tight and corrosion-free.
Access settings via charge controller buttons and LCD display.
Charge Controller Display: Shows battery voltage, charging current, load current, battery percentage.
Button Functions: MENU (access settings), ENTER (select/confirm), UP/DOWN (navigate/adjust values).
Configurable Settings: Battery type (SEAL, GEL, FLOOD), charging voltage (14.4V/14.7V), load control mode (manual/timer), low voltage disconnect (10.5V-12V), load timer settings (1-15 hours).
Connect DC and AC loads to appropriate outputs.
Tip: Calculate total wattage before connecting devices. Start with highest priority loads first.
Daily operation and monitoring procedures.
WARNING! Do not exceed inverter's rated capacity. Disconnect loads before performing maintenance.
Multiple protection mechanisms: Overcharge protection, Over-discharge protection, Short-circuit protection, Reverse polarity protection, Overload protection, Temperature compensation.
Regular maintenance ensures optimal performance and longevity.
Weekly: Clean solar panel surface with soft cloth and water. Check all connections.
Monthly: Inspect battery terminals for corrosion. Check cable insulation.
Seasonally: Adjust panel tilt angle. Tighten all mounting hardware.
Battery Maintenance: Keep battery clean and dry. Check electrolyte levels (flooded type only).
CAUTION! Never touch electrical connections with wet hands. Wear eye protection when working with batteries.
CE Certified: Complies with European safety standards. RoHS Compliant: Free of hazardous substances. IP65 Rated: Weatherproof solar panel. FCC Part 15: Class B digital device. Copyright © 2023 Eco-Worthy. All trademarks property of their respective owners. For technical support, visit www.eco-worthy.com or contact [email protected].
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power output | Battery discharged/Faulty connections | Check battery voltage; verify all connections; ensure solar panel receiving sunlight. |
| Low charging current | Dirty panel/Shading | Clean panel surface; remove obstructions; check for shadows. |
| Inverter not working | Low battery/Overload | Charge battery; reduce connected load; check battery connections. |
| Controller display blank | No power/Reverse polarity | Check battery and solar connections; verify correct polarity. |
| Battery not holding charge | Old battery/Excessive load | Test battery capacity; reduce power consumption; replace if necessary. |
| Overload protection triggered | Too many devices connected | Disconnect some loads; restart system; check individual device wattage. |
Reset Procedure: Disconnect solar panel and battery for 5 minutes, then reconnect.
Service: [email protected]; www.eco-worthy.com; +1-800-555-ECO1