Deltran HYPERION Instruction Manual

The Deltran HYPERION is a high-performance battery charger and maintainer designed for 12V lead-acid batteries (AGM, GEL, WET). It features multi-stage charging (Bulk, Absorption, Float), microprocessor control, reverse polarity protection, spark-proof technology, and compatibility with various battery types. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Indicators 6. Connecting to Battery 7. Charging Process 8. Maintenance Mode 9. Care & Cleaning 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Microprocessor-controlled charger, LED status indicators, Alligator clips, Ring terminals, AC power cord.

FeatureDescription
Multi-stage chargingBulk, Absorption, Float for optimal battery health
Battery type selectionAGM, GEL, WET (Standard)
Reverse polarity protectionPrevents damage from incorrect connections
Spark-proof technologySafe connection to battery terminals
Float/Maintenance modeMaintains battery at full charge indefinitely
LED status indicatorsPower, Charging, Fault, Complete
Desulfation modeHelps recover sulfated batteries
Temperature compensationAdjusts charge voltage based on ambient temperature
Compact designLightweight and portable
Wide input voltage100-240V AC, 50/60Hz

Installation

Unpack and inspect contents. Place on stable, dry, well-ventilated surface.

  1. Select location: Ensure area is dry, away from flammable materials and battery.
  2. AC power connection: Plug charger into standard 120V/240V AC outlet.
  3. Battery connection: Connect charger to battery following proper polarity.
  4. Verify connections: Ensure all connections are secure before powering on.

WARNING! Risk of explosive gases. Work in well-ventilated area. Keep sparks and flames away from battery.

First-Time Setup

Power on charger; follow LED indicators.

  1. Select battery type: Press MODE button to cycle through AGM, GEL, WET.
  2. Connect to battery: Attach red clip to positive (+), black clip to negative (-).
  3. Initiate charging: Charger will automatically begin multi-stage process.
  4. Monitor status: LED indicators show charging progress and completion.

CAUTION! Do not connect or disconnect clips while charger is powered on. Always connect to battery first, then to AC power.

Specifications

Controls and Indicators

Front Panel: POWER button, MODE button, LED status indicators.

LED Indicators:

Controls: POWER - Turns charger on/off. MODE - Selects battery type (AGM, GEL, WET).

Connecting to Battery

Always connect charger to battery before connecting to AC power.

  1. Ensure charger is OFF and unplugged from AC power.
  2. Connect red alligator clip to positive (+) battery terminal.
  3. Connect black alligator clip to negative (-) battery terminal or chassis ground.
  4. Plug charger into AC power outlet.
  5. Press POWER button to begin charging.

Tip: For maintenance charging, connect directly to battery terminals for best results.

Charging Process

Automatic multi-stage charging for optimal battery health.

  1. Bulk Stage: Constant current charge until battery reaches approximately 80% capacity.
  2. Absorption Stage: Constant voltage charge to bring battery to 100% capacity.
  3. Float Stage: Maintenance voltage to keep battery at full charge indefinitely.
  4. Completion: LED turns green when battery is fully charged.
  5. Maintenance: Automatically switches to float mode to prevent overcharging.

WARNING! Do not attempt to charge frozen or damaged batteries. Ensure battery electrolyte levels are proper before charging.

Maintenance Mode

Float/maintenance mode keeps battery at optimal charge during storage.

  1. Connect charger to battery as described in section 7.
  2. Charger automatically enters maintenance mode after completing charge cycle.
  3. LED indicator shows green when in maintenance mode.
  4. Charger can remain connected indefinitely without overcharging battery.

Note: Ideal for seasonal vehicles, boats, RVs, and other infrequently used equipment.

Care & Cleaning

Unplug from AC power and disconnect from battery before cleaning. Use dry cloth only; do not use liquids or solvents.

CAUTION! Do not immerse charger in water or other liquids. Keep ventilation openings clean and unobstructed.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits for residential use. CE certified for European market. RoHS compliant. Copyright © 2023 Deltran Corporation; all rights reserved. For technical support, visit www.deltran.com or contact 1-800-328-2921.

Troubleshooting

SymptomPossible CauseCorrective Action
Charger won't turn onNo AC power / Faulty outletCheck AC outlet; ensure charger is properly plugged in.
Amber LED (Fault)Reverse polarity / Bad connectionCheck battery connections; ensure correct polarity.
Charger stops prematurelyOver-temperature / Battery issueAllow charger to cool; check battery condition.
Battery not chargingDeeply discharged / SulfatedTry recovery mode; battery may need replacement.
LED flashing amberDesulfation mode activeAllow process to complete (may take several hours).
Spark when connectingCharger powered onAlways connect clips before plugging into AC power.

Reset: Unplug from AC power, disconnect from battery, wait 30 seconds, then reconnect.

Service: 1-800-328-2921; www.deltran.com