The Conrad Multi 300 is a versatile multi-function tester designed for electrical diagnostics, featuring voltage detection, continuity testing, resistance measurement, and basic functionality checks. It operates on standard batteries, includes a digital display, test leads, protective holster, and auto-ranging capabilities. Below are key sections for safety, features, operation, measurement procedures, maintenance, and troubleshooting.
Key components: Digital LCD display, Function selector dial, Test lead inputs (COM and VΩmA), Hold button, Data hold function, Auto power-off, Low battery indicator, Overload protection.
| Feature | Description |
|---|---|
| Voltage Measurement | AC/DC voltage up to 600V |
| Continuity Test | Audible buzzer for circuit continuity |
| Resistance Measurement | Measures resistance up to 2MΩ |
| Diode Test | Checks diode forward voltage drop |
| Battery Test | Tests standard battery voltages |
| Auto-ranging | Automatically selects appropriate measurement range |
| Data Hold | Freezes display reading |
| Overload Protection | Protects against voltage spikes |
| Low Battery Indicator | Shows when batteries need replacement |
| Protective Holster | Rubber case for drop protection |
Read all instructions before use. Always follow electrical safety protocols.
WARNING! Electric shock hazard. Use extreme caution when measuring live circuits. Never touch exposed metal parts of test leads.
Prepare the tester for first use.
CAUTION! Verify battery installation is correct before use. Incorrect polarity may damage the tester.
Front Panel: Function selector dial, LCD display, HOLD button, Test lead jacks.
Display Symbols: AC/DC indicators, Low battery, Overload (OL), Data hold (H), Decimal points.
Function Selector Positions: OFF, V⎓ (DC voltage), V~ (AC voltage), Ω (resistance), ))) (continuity), diode symbol, battery test.
HOLD Button: Press to freeze current reading; press again to resume live measurement.
Voltage: Select V⎓ or V~, connect leads in parallel with circuit. Resistance/Continuity: Select Ω or )))), ensure circuit is de-energized, connect leads across component.
Tip: Ensure test leads make good contact with test points for accurate readings.
Use the selector dial to choose measurement function.
WARNING! Never rotate selector dial while test leads are connected to a live circuit. Always return to OFF position when not in use.
Replace batteries when low battery indicator appears.
CAUTION! Use only fresh batteries of the same type. Do not mix old and new batteries.
Clean with dry cloth only. Store in protective case when not in use.
CAUTION! Do not expose to extreme temperatures, moisture, or direct sunlight for extended periods.
Complies with relevant electrical safety standards. CE marked for European market. Copyright © Conrad Electronic SE. For technical support, visit www.conrad.com or contact customer service at +49 (0) 9243 50-0.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Dead batteries | Replace batteries with fresh ones. |
| Inaccurate readings | Weak batteries | Replace batteries; check test lead connections. |
| Display shows "OL" | Overload/out of range | Select higher range or check circuit voltage. |
| Continuity buzzer not sounding | High resistance/open circuit | Check circuit continuity; resistance may be above 50Ω. |
| Tester turns off unexpectedly | Auto power-off activated | Rotate selector dial to OFF then back to desired function. |
Reset: Remove batteries for 30 seconds, then reinstall.
Service: +49 (0) 9243 50-0; www.conrad.com