Chamberlain 912GA Install Manual

The Chamberlain 912GA is a 1/2 HP chain drive garage door opener designed for residential use. It features a durable steel rail system, secure rolling code technology, a wall-mounted control panel, two remote transmitters, safety sensors with auto-reverse, manual release system, and adjustable travel limits. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Safety Information 3. Installation Requirements 4. Installation Steps 5. Specifications 6. Controls and Programming 7. Travel Limit Adjustment 8. Force Adjustment 9. Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Power unit with 1/2 HP motor, Steel rail and chain drive, Wall control panel, Two 3-button remote transmitters, Safety reversing sensors, Manual release cord and handle, Light bulb socket.

FeatureDescription
Motor Power1/2 HP chain drive for residential garage doors
Drive SystemSteel rail with chain for durability
SecurityRolling code technology for secure operation
Control PanelWall-mounted with door control and light buttons
Remote TransmittersTwo 3-button remotes included
Safety SensorsInfrared beam for auto-reverse if obstruction detected
Manual ReleaseCord and handle for manual operation during power outage
Travel LimitsAdjustable for precise open and close positions
Force AdjustmentSeparate open and close force settings
LightingBuilt-in light socket for illumination

Safety Information

Read all instructions before installation and operation.

  1. Installation: Ensure garage door is properly balanced and in good condition.
  2. Safety Sensors: Must be installed no more than 6 inches above floor; align properly.
  3. Auto-Reverse: Test monthly by placing a 2x4 board on floor in door's path.
  4. Manual Release: Familiarize all users with manual release operation.
  5. Keep clear: Never stand or walk under a moving door.

WARNING! Serious injury or death can occur from improper installation or use. Disconnect power before servicing.

Installation Requirements

Tools needed: Stepladder, Wrench set, Screwdrivers, Drill with bits, Level, Tape measure, Pliers, Safety glasses.

CAUTION! Verify door springs are properly adjusted and door moves freely before installation.

Installation Steps

Follow steps in order for proper installation.

  1. Assemble rail: Connect rail sections as per manual; secure with provided hardware.
  2. Mount header bracket: Attach to door header using lag screws; ensure level.
  3. Install power unit: Attach to ceiling joists with mounting brackets; ensure unit is level.
  4. Attach rail to door: Connect trolley to door arm; secure to top section of door.
  5. Install safety sensors: Mount on each side of door 6 inches above floor; align LEDs.
  6. Wire controls: Connect wall control and sensors to power unit terminals.
  7. Program remotes: Follow programming steps in Controls section.
  8. Adjust limits: Set open and close travel limits.
  9. Test operation: Run several complete cycles; test safety reverse feature.

Tip: Have an assistant during installation to hold components in place.

Specifications

Controls and Programming

Wall Control Panel: DOOR button (open/close), LIGHT button (on/off), LOCK button (disable remotes).

Remote Programming:

  1. Locate LEARN button on back of power unit (near light socket).
  2. Press and release LEARN button; LED will light for 30 seconds.
  3. Within 30 seconds, press and hold button on remote until opener light blinks.
  4. Test remote operation.

Keypad Programming (if applicable): Enter default PIN (usually 1-2-3-4), press PROG, enter new 4-digit PIN, press ENTER.

Note: To erase all remotes, press and hold LEARN button until LED turns off (about 6 seconds).

Travel Limit Adjustment

Adjust open and close positions for proper door alignment.

  1. Open adjustment: Locate OPEN limit screw on power unit; turn clockwise to decrease travel, counterclockwise to increase.
  2. Close adjustment: Locate CLOSE limit screw; adjust similarly.
  3. Test: Run door through complete cycles; adjust until door fully opens and closes completely on floor.
  4. Final check: Ensure door seals properly when closed without excessive force.

WARNING! Do not adjust limits while door is moving. Make small adjustments and test between changes.

Force Adjustment

Adjust open and close force to match door weight and conditions.

  1. Open force: Locate OPEN force adjustment; turn clockwise to increase force, counterclockwise to decrease.
  2. Close force: Locate CLOSE force adjustment; adjust similarly.
  3. Test: Door should open completely without straining; should reverse if obstruction encountered during close.
  4. Safety test: Place 2x4 board on floor in door's path; door should reverse within 2 seconds of contact.

CAUTION! Excessive force can cause injury or damage. Adjust to minimum force needed for reliable operation.

Maintenance

Regular maintenance ensures long-term reliable operation.

Note: Disconnect power before performing any maintenance.

Regulatory Information

UL 325 compliant for residential garage door openers. FCC Part 15: Class B digital device; complies with interference limits. Copyright © Chamberlain Group LLC. For support, visit www.chamberlain.com or contact 1-800-528-9131.

Troubleshooting

SymptomPossible CauseCorrective Action
Door doesn't movePower outage/breakerCheck power source; reset breaker; ensure manual release is engaged.
Door reverses when closingObstruction/sensor alignmentClear door path; realign safety sensors; clean sensor lenses.
Remote doesn't workBattery/range/programmingReplace battery; check range (max 100 ft); reprogram remote.
Door doesn't close completelyLimit adjustmentAdjust CLOSE limit screw; check for obstructions in track.
Noisy operationLubrication/hardwareLubricate chain; tighten loose hardware; check door balance.
Light doesn't turn onBulb/settingsReplace bulb; check light timer setting on wall control.

Reset: To reset opener to factory defaults, press and hold LEARN button for 10 seconds until LED blinks rapidly.

Service: 1-800-528-9131; www.chamberlain.com