Bresser 3810030 Instruction Manual

The Bresser 3810030 is a precision optical instrument designed for detailed observation and measurement. This manual provides comprehensive instructions for safety, features, assembly, setup, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your device.

1. Features at a Glance 2. Assembly & Installation 3. First-Time Setup 4. Technical Specifications 5. Controls & Operation 6. Connecting Accessories 7. Calibration & Measurement 8. Advanced Functions 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: High-quality optical lens system, precision focusing mechanism, adjustable stand, integrated measurement scale, eyepiece, objective lens, and fine adjustment knobs.

FeatureDescription
Optical SystemMulti-coated achromatic lenses for clear, sharp images
MagnificationVariable magnification range with interchangeable eyepieces
Focusing MechanismCoarse and fine focus adjustment knobs
IlluminationBuilt-in LED illumination with adjustable intensity
StageMechanical stage with XY movement controls
Measurement ScaleIntegrated micrometer scale for precise measurements
Power SupplyAC adapter input or battery operation
EyepieceWide-field eyepiece with diopter adjustment
Objective TurretRevolving nosepiece with multiple objective lenses
Carrying CaseProtective case for storage and transport

Assembly & Installation

Unpack all components carefully and verify contents against packing list. Place on stable, level surface.

  1. Assemble stand: Attach base to vertical column using provided screws.
  2. Install arm and head: Secure the observation head to the arm, then attach to column.
  3. Mount objectives: Place objective lenses into turret slots, ensuring they click into place.
  4. Insert eyepiece: Place eyepiece into observation tube, secure with retaining ring.
  5. Connect power: Plug AC adapter into power input, then connect to wall outlet.

WARNING! Handle optical components by edges only. Avoid touching glass surfaces. Ensure all screws are tightened securely but do not overtighten.

First-Time Setup

Power on the device and perform initial calibration for optimal performance.

  1. Eye adjustment: Set interpupillary distance by moving eyepieces until single circular field is visible.
  2. Diopter adjustment: Focus using coarse knob, then fine-tune with diopter ring on left eyepiece.
  3. Illumination setup: Adjust brightness control to comfortable level for your observation.
  4. Stage calibration: Center the stage and ensure smooth movement in all directions.
  5. Objective alignment: Rotate turret to lowest magnification, focus on sample, check alignment.

CAUTION! Never look directly at bright light source through eyepiece. Always start with lowest magnification and lowest light intensity.

Technical Specifications

Controls & Operation

Main controls located on both sides of device. Front Panel: Power switch, illumination control, focus knobs.

Control Panel: POWER, ILLUMINATION +/-, FINE FOCUS, COARSE FOCUS, STAGE CONTROLS (X/Y movement).

Optical Adjustment: Interpupillary distance, diopter adjustment, condenser height, iris diaphragm. Illumination: Brightness control, field diaphragm. Mechanical: Stage movement, focus tension adjustment, nosepiece rotation. Special Functions: Measurement mode, calibration mode, digital interface (if equipped).

Connecting Accessories

Camera Port: For digital camera attachment. External Light Source: Additional illumination input. Computer Interface: USB connection for software control.

  1. Turn off device before connecting accessories.
  2. Align accessory ports carefully, do not force connections.
  3. Secure with provided screws or locking mechanisms.
  4. Install necessary drivers or software for digital accessories.

Tip: Refer to accessory manual for specific installation instructions. Ensure compatibility before purchase.

Calibration & Measurement

Precise measurement requires proper calibration of the measurement scale.

  1. Stage micrometer: Place calibration slide on stage.
  2. Focus: Use 10x objective to focus on calibration lines.
  3. Align scales: Rotate eyepiece until measurement scale aligns with stage micrometer.
  4. Calibrate: Using known distance on stage micrometer, calibrate eyepiece scale.
  5. Verify: Check calibration with different objectives if necessary.
  6. Measure: Place sample, align with scale, read measurement directly.
  7. Record: Note measurements with corresponding magnification.

WARNING! Recalibrate when changing objectives or eyepieces. Handle calibration slides with care to avoid scratches.

Advanced Functions

Darkfield Observation: Install darkfield stop under condenser. Phase Contrast: Requires special phase contrast objectives and condenser. Polarized Light: Install polarizer and analyzer filters. Fluorescence: Requires fluorescence attachment and specific light source.

Care & Maintenance

Unplug device before cleaning. Use only recommended cleaning materials.

  1. Lens cleaning: Use lens paper and appropriate lens cleaner. Wipe gently in circular motion.
  2. Body cleaning: Damp cloth with mild detergent, then dry immediately.
  3. Mechanical parts: Light machine oil on moving parts annually.
  4. Storage: Cover with dust cover, store in dry environment.
  5. Battery care: Remove batteries if not used for extended periods.

CAUTION! Never use alcohol or acetone on optical surfaces. Do not disassemble optical components. Avoid extreme temperatures and humidity.

Regulatory Information

CE Certified: Complies with European safety standards. RoHS Compliant: Free of hazardous substances. FCC Part 15: Class B digital device. Manufactured under ISO 9001 quality standards. Copyright © Bresser GmbH. All rights reserved. For technical support, visit www.bresser.com or contact +49 (0) 2162 / 367 500.

Troubleshooting

SymptomPossible CauseCorrective Action
No image or dark imageLight source off/obstructedCheck power connection; adjust brightness; remove obstruction from light path.
Blurry imageImproper focus/dirty opticsRefocus using coarse then fine adjustment; clean objective and eyepiece lenses.
Double imageIncorrect interpupillary distanceAdjust distance between eyepieces until single image appears.
Image moves when focusingLoose stage or sampleTighten stage locking screws; secure sample properly.
Uneven illuminationMisaligned condenserCenter condenser; adjust field diaphragm; clean light source.
Mechanical stiffnessLack of lubrication/dirtClean moving parts; apply light machine oil if necessary.
Measurement inaccuracyImproper calibrationRecalibrate using stage micrometer; check objective magnification.

Reset: Power cycle device. For persistent issues, perform factory reset if available in settings.

Service: Contact authorized service center. Do not attempt repairs that require disassembly of optical system.

Bresser 3810030 Instruction Manual © - All Rights Reserved 2025