The Bresser 3810030 is a precision optical instrument designed for detailed observation and measurement. This manual provides comprehensive instructions for safety, features, assembly, setup, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your device.
Key components: High-quality optical lens system, precision focusing mechanism, adjustable stand, integrated measurement scale, eyepiece, objective lens, and fine adjustment knobs.
| Feature | Description |
|---|---|
| Optical System | Multi-coated achromatic lenses for clear, sharp images |
| Magnification | Variable magnification range with interchangeable eyepieces |
| Focusing Mechanism | Coarse and fine focus adjustment knobs |
| Illumination | Built-in LED illumination with adjustable intensity |
| Stage | Mechanical stage with XY movement controls |
| Measurement Scale | Integrated micrometer scale for precise measurements |
| Power Supply | AC adapter input or battery operation |
| Eyepiece | Wide-field eyepiece with diopter adjustment |
| Objective Turret | Revolving nosepiece with multiple objective lenses |
| Carrying Case | Protective case for storage and transport |
Unpack all components carefully and verify contents against packing list. Place on stable, level surface.
WARNING! Handle optical components by edges only. Avoid touching glass surfaces. Ensure all screws are tightened securely but do not overtighten.
Power on the device and perform initial calibration for optimal performance.
CAUTION! Never look directly at bright light source through eyepiece. Always start with lowest magnification and lowest light intensity.
Main controls located on both sides of device. Front Panel: Power switch, illumination control, focus knobs.
Control Panel: POWER, ILLUMINATION +/-, FINE FOCUS, COARSE FOCUS, STAGE CONTROLS (X/Y movement).
Optical Adjustment: Interpupillary distance, diopter adjustment, condenser height, iris diaphragm. Illumination: Brightness control, field diaphragm. Mechanical: Stage movement, focus tension adjustment, nosepiece rotation. Special Functions: Measurement mode, calibration mode, digital interface (if equipped).
Camera Port: For digital camera attachment. External Light Source: Additional illumination input. Computer Interface: USB connection for software control.
Tip: Refer to accessory manual for specific installation instructions. Ensure compatibility before purchase.
Precise measurement requires proper calibration of the measurement scale.
WARNING! Recalibrate when changing objectives or eyepieces. Handle calibration slides with care to avoid scratches.
Darkfield Observation: Install darkfield stop under condenser. Phase Contrast: Requires special phase contrast objectives and condenser. Polarized Light: Install polarizer and analyzer filters. Fluorescence: Requires fluorescence attachment and specific light source.
Unplug device before cleaning. Use only recommended cleaning materials.
CAUTION! Never use alcohol or acetone on optical surfaces. Do not disassemble optical components. Avoid extreme temperatures and humidity.
CE Certified: Complies with European safety standards. RoHS Compliant: Free of hazardous substances. FCC Part 15: Class B digital device. Manufactured under ISO 9001 quality standards. Copyright © Bresser GmbH. All rights reserved. For technical support, visit www.bresser.com or contact +49 (0) 2162 / 367 500.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No image or dark image | Light source off/obstructed | Check power connection; adjust brightness; remove obstruction from light path. |
| Blurry image | Improper focus/dirty optics | Refocus using coarse then fine adjustment; clean objective and eyepiece lenses. |
| Double image | Incorrect interpupillary distance | Adjust distance between eyepieces until single image appears. |
| Image moves when focusing | Loose stage or sample | Tighten stage locking screws; secure sample properly. |
| Uneven illumination | Misaligned condenser | Center condenser; adjust field diaphragm; clean light source. |
| Mechanical stiffness | Lack of lubrication/dirt | Clean moving parts; apply light machine oil if necessary. |
| Measurement inaccuracy | Improper calibration | Recalibrate using stage micrometer; check objective magnification. |
Reset: Power cycle device. For persistent issues, perform factory reset if available in settings.
Service: Contact authorized service center. Do not attempt repairs that require disassembly of optical system.