The Blue Wave FlowXtreme NS1002 is a high-performance, portable water flow meter designed for professional and residential use. It features a digital LCD display, real-time flow rate and total volume measurement, durable construction with IP67 waterproof rating, data logging capabilities, rechargeable battery, and multiple unit options (GPM, LPM, m³/h). Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Digital Flow Sensor, LCD Display with backlight, Control Buttons, USB-C Charging Port, Data Output Port, Mounting Bracket.
| Feature | Description |
|---|---|
| Digital Flow Sensor | High-accuracy turbine sensor for precise flow measurement |
| LCD Display | Shows real-time flow rate, total volume, battery level, and unit |
| Control Buttons | Power, Mode, Reset, and Unit selection |
| USB-C Charging Port | For recharging internal lithium-ion battery |
| Data Output Port | For connecting to PC or data logger (RS-232 compatible) |
| Mounting Bracket | Adjustable bracket for secure installation on pipes |
| POWER | Turns device on/off |
| MODE | Cycles through display modes (Flow Rate, Total Volume, Settings) |
| RESET | Resets total volume counter to zero |
| UNIT | Switches between measurement units (GPM, LPM, m³/h) |
Unpack and inspect contents. Ensure proper pipe compatibility.
WARNING! Ensure pipe is depressurized before installation. Use proper tools to avoid injury.
Power on device; follow initial setup prompts.
CAUTION! Do not expose electronics to water during setup. Keep display unit dry.
Access menu via MODE button. Front Panel: POWER, MODE, RESET, UNIT.
Display Modes: Real-time Flow Rate, Total Volume, Battery Status, Settings Menu.
Settings: Unit selection, Backlight timeout (15s, 30s, 60s, Off), Logging interval (1s to 1h), Calibration reset, Factory reset. Data: Hold MODE for 3 seconds to enter data view mode; scroll through logged points.
PC Connection: Use provided USB-to-RS232 cable. Data Logger: Connect via data output port.
Tip: Ensure device is charged or connected to power during data transfer.
Supports internal storage of up to 10,000 data points.
WARNING! Export data regularly to avoid memory overflow. Do not disconnect during transfer.
Auto-calibration: Hold MODE for 5 seconds in setup mode. Manual calibration: Requires known flow reference.
Note: Calibrate annually or if accuracy drifts. Use clean water only.
Power off and disconnect before cleaning. Wipe exterior with damp cloth; clean sensor with soft brush and water.
CAUTION! Do not use harsh chemicals or submerge display unit. Store in dry, cool place.
FCC Part 15: Class B digital device; complies with interference limits. CE marked for European compliance. Copyright © 2025 Blue Wave Technologies; trademarks of Blue Wave Inc. For support, visit www.bluewavetech.com or contact 1-800-555-0199.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Battery depleted | Charge device fully; ensure power button is pressed. |
| Inaccurate reading | Sensor dirty/calibration off | Clean sensor; recalibrate using reference flow. |
| No data logging | Memory full/logging disabled | Clear memory; enable logging in settings. |
| PC not connecting | Driver/COM port issue | Install correct driver; check COM port settings. |
| Flow reading zero | Sensor blockage/no flow | Check for pipe blockage; ensure flow is present. |
Reset: Settings > System > Factory Reset (erases all data).
Service: 1-800-555-0199; www.bluewavetech.com