The Berger XT 60 W is a 60-watt LED floodlight designed for outdoor and commercial lighting applications, featuring high luminous efficacy, IP65 weatherproof rating, wide beam angle, durable aluminum housing, integrated heat sink, universal voltage input (100-240V AC, 50/60Hz), and multiple mounting options. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: High-power LED array, Aluminum housing, Integrated driver, Mounting bracket, Cable gland, Adjustable yoke.
| Feature | Description |
|---|---|
| LED Power | 60 watts high-efficiency LED |
| Luminous Flux | Up to 6000 lumens |
| Beam Angle | 120° wide flood beam |
| IP Rating | IP65 (dust tight and protected against water jets) |
| Housing Material | Die-cast aluminum with thermal management |
| Input Voltage | 100-240V AC, 50/60Hz universal |
| Color Temperature | 3000K (Warm White), 4000K (Neutral White), 5000K (Cool White) |
| Dimming | Optional 0-10V dimming compatible |
| Mounting | Wall, pole, or ground mounting with adjustable bracket |
| Operating Temperature | -20°C to +40°C |
Unpack and inspect contents. Ensure mounting surface is stable and can support weight.
WARNING! Installation must be performed by qualified electrician. Ensure power is disconnected before wiring.
After installation, restore power and verify operation.
CAUTION! Do not touch LED surface during operation; it becomes hot. Allow to cool before handling.
No onboard controls; operation is via mains power switch or external dimmer.
External Dimming (Optional): Connect 0-10V dimmer to DIM+ and DIM- terminals. Dimming range: 10% to 100% brightness.
Color Temperature Selection: Fixed at factory; model variant indicated on label (WW=3000K, NW=4000K, CW=5000K).
Mounting Adjustment: Yoke allows 180° vertical and 360° horizontal rotation.
Primarily connects to mains power. Optional connections for dimming and sensors.
Tip: Use waterproof connectors for outdoor connections. Ensure polarity is correct for dimming.
Continuous operation; no modes other than dimmed level.
WARNING! Do not operate in ambient temperatures above 40°C. Ensure adequate ventilation.
Over-temperature Protection: Automatically reduces power if overheating detected. Short-Circuit Protection: Driver protected against output short. Surge Protection: 2kV surge withstand. Isolation Class: Class I (grounding required).
Disconnect power before cleaning. Use soft cloth with mild detergent if needed. Do not use abrasive cleaners.
CAUTION! Do not spray water directly at cable gland or joints. Ensure light is cool before cleaning.
CE, RoHS, ENEC, and UKCA compliant. Meets EN 60598-1 and EN 60598-2-5 standards. Copyright © 2025 Berger Lighting; trademarks of Berger Group. For support, visit www.bergerlighting.com or contact +44 (0)1234 567890.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Light does not turn on | No power/wiring | Check circuit breaker; verify wiring connections; ensure voltage is within range. |
| Flickering | Loose connection/dimmer | Tighten all terminals; check dimmer compatibility and wiring. |
| Dim output | Dimmer setting/overheat | Adjust dimmer to maximum; allow to cool if overheated. |
| Water inside housing | Seal failure | Turn off power; check and replace O-ring; ensure cable gland is tight. |
| Overheating | Poor ventilation/ambient temp | Ensure clear space around light; do not cover; reduce ambient temperature. |
Reset: Disconnect power for 30 seconds and reconnect.
Service: +44 (0)1234 567890; www.bergerlighting.com/support