The Berger XT 300 W is a high-performance 300-watt power inverter designed for automotive and off-grid applications, featuring pure sine wave output, multiple AC outlets, USB charging ports, overload protection, low voltage alarm, and cooling fan. Operates on 12V DC input, producing 120V AC, 60Hz output. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Pure sine wave inverter, DC input terminals, AC outlets, USB ports, LCD display, cooling fan, overload protection circuit.
| Feature | Description |
|---|---|
| Pure Sine Wave Output | Clean power suitable for sensitive electronics |
| AC Output | Two 120V AC outlets (300W continuous) |
| USB Charging Ports | Two USB ports (5V/2.4A each) |
| LCD Display | Shows input voltage, output wattage, and warnings |
| Overload Protection | Automatic shutdown when exceeding 300W |
| Low Voltage Alarm | Audible alert when input voltage drops below 10.5V |
| Cooling Fan | Thermally controlled for efficient heat dissipation |
| DC Input Terminals | For connecting to 12V battery |
| Power Switch | Main power control |
| Remote Control Port | Optional remote switch connection |
Unpack and inspect contents. Ensure proper ventilation.
WARNING! Ensure battery is disconnected during installation. Use appropriate gauge cables (minimum 8 AWG).
Power on inverter; check LCD display.
CAUTION! Do not exceed 300W total load. Ensure proper ventilation around unit.
Access settings via front panel buttons. Front Panel: POWER, MODE, SET, UP/DOWN arrows.
LCD Display: Shows input voltage, output power, temperature, warning icons.
Settings Menu: Low voltage cutoff (10.5-11.5V), fan mode (AUTO/MANUAL), brightness, alarm volume, load calculation. Protection Settings: Overload threshold (300W adjustable), temperature cutoff, restart delay. Display: Backlight timeout, voltage display format, power saving mode.
AC devices: Plug into outlets. USB devices: Connect to USB ports.
Tip: Start with lowest power device first to test system stability.
Supports continuous, standby, and eco modes.
WARNING! Do not operate in enclosed spaces. Keep away from flammable materials.
Overload Protection: Automatic shutdown when exceeding 300W. Low Voltage Cutoff: Protects battery from deep discharge. Temperature Control: Fan activates at 40°C. Short Circuit Protection: Immediate shutdown on detected short.
Disconnect from battery before cleaning. Use compressed air to remove dust from vents.
CAUTION! Do not use liquids for cleaning. Check connections monthly for corrosion.
FCC Part 15: Class B digital device; complies with interference limits. UL 458 certified for marine and vehicle use. Copyright © 2025 Berger Power Systems; trademarks of Berger Industrial GmbH. For support, visit www.bergerpower.com or contact 1-800-555-3000.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power output | Battery/low voltage | Check battery connections; ensure voltage > 10.5V. |
| Overload shutdown | Exceeded 300W limit | Disconnect devices; restart; reduce total load. |
| Fan not running | Temperature/obstruction | Ensure vents clear; fan activates at 40°C. |
| Low voltage alarm | Battery discharge | Recharge battery; check alternator output. |
| USB ports not working | Overcurrent protection | Disconnect devices; wait 30 seconds; reconnect. |
Reset: Hold POWER + MODE for 5 seconds to factory reset.
Service: 1-800-555-3000; www.bergerpower.com/support