The Berger+Schröter 32493 is a precision industrial measurement and control instrument designed for professional applications. It features high-accuracy sensors, digital display with backlight, multiple measurement modes, data logging capability, IP65-rated housing, rechargeable battery power, USB connectivity for data transfer, and customizable alarm thresholds. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: High-precision sensor array, Digital LCD display, Control buttons, USB port, Battery compartment, Mounting bracket.
| Feature | Description |
|---|---|
| Measurement Sensor | High-accuracy sensor for precise readings |
| Digital Display | Backlit LCD with multiple data views |
| Control Buttons | For mode selection and parameter adjustment |
| USB Port | For data transfer and firmware updates |
| Battery Compartment | For rechargeable battery power |
| Mounting Bracket | For secure installation on surfaces |
| POWER | Turns device on/off |
| MODE | Cycles through measurement modes |
| SET | Enters setting mode |
| DATA | Accesses data logging functions |
Unpack and inspect contents. Ensure all components are present.
WARNING! Device contains sensitive electronics; handle with care to avoid damage. Ensure mounting surface can support device weight.
Power on device; follow initialization procedure.
CAUTION! Perform calibration in stable environment for accurate readings.
Access menu system via SET button. Front Panel: POWER, MODE, SET, DATA, UP/DOWN arrows.
Menu Structure: MEASUREMENT MODES, ALARM SETTINGS, DATA LOGGING, SYSTEM CONFIG, CALIBRATION.
Measurement Modes: Continuous, Spot, Average, Peak Hold. Alarm Settings: High/Low thresholds, audible/visual alerts. Data Logging: Interval setting, start/stop control, data review. System Config: Language, units, display brightness, auto-off timer. Calibration: Zero calibration, span calibration, calibration history.
USB: For computer connection. Optional: Wireless module for remote monitoring.
Tip: Use included USB cable for guaranteed compatibility.
Supports multiple measurement modes for various applications.
WARNING! Do not exceed specified measurement ranges. Avoid extreme environmental conditions.
Data Logging: Configure intervals from 1 second to 24 hours. Data Export: Transfer via USB to computer software. Data Review: Scroll through stored measurements on device display.
Power off before cleaning. Use soft, dry cloth for display; mild detergent for housing if needed.
Maintenance Schedule: Monthly: Visual inspection. Quarterly: Calibration check. Annually: Full calibration by authorized service center.
CAUTION! Do not immerse in liquids. Avoid abrasive cleaners.
CE Certified: Complies with European directives for electromagnetic compatibility and safety. RoHS Compliant: Contains no restricted hazardous substances. FCC Part 15: Class A digital device. Copyright © 2023 Berger+Schröter GmbH; all rights reserved. For technical support, visit www.bergerschroeter.com or contact +49 (0)30 12345678.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No display | Battery/power issue | Check battery charge; connect to power adapter; ensure POWER is pressed. |
| Inaccurate readings | Calibration needed | Perform calibration procedure; ensure proper measurement conditions. |
| Device not connecting to computer | Driver/USB issue | Install latest drivers; try different USB port; use included cable. |
| Data not logging | Memory full/settings | Clear memory; check logging interval settings; ensure logging is activated. |
| Alarms not triggering | Threshold settings | Verify alarm thresholds are properly set; check alert mode (visual/audible). |
Reset: Menu > System > Factory Reset (note: erases all data and settings).
Service: Contact authorized Berger+Schröter service center. Do not attempt internal repairs.