Atempower AP100MS User Manual

The Atempower AP100MS is a 100-watt portable power station with multiple output ports, built-in lithium-ion battery, AC inverter, USB-C PD, USB-A, DC outputs, LCD display, and solar charging capability. Designed for outdoor activities, emergencies, and mobile device charging. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Charging & Power Management 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Portable power station with lithium-ion battery, LCD display, multiple output ports, and charging inputs.

FeatureDescription
AC Output100W pure sine wave inverter (120V, 60Hz)
USB-C PD PortPower Delivery up to 60W for fast charging
USB-A PortsTwo standard USB ports (5V/2.4A each)
DC Output12V/10A carport and 5.5mm DC jack
LCD DisplayShows battery level, input/output power, and status
Solar Charging InputSupports up to 100W solar panel (MC4 connector)
AC Charging InputWall charger input (100-240V, 50/60Hz)
Car Charging Input12V car charger input
POWER ButtonTurns unit on/off
LED FlashlightBuilt-in emergency light with SOS mode

Installation

Unpack and inspect contents. Place on stable, dry surface.

  1. Initial Charge: Connect included AC adapter to charging port and wall outlet.
  2. Connect devices: Use appropriate cables for USB, DC, or AC outputs.
  3. For solar charging: Connect compatible solar panel to solar input port.
  4. Ensure proper ventilation during use and charging.

WARNING! Do not expose to water or extreme temperatures. Keep away from flammable materials.

First-Time Setup

Power on unit; check LCD display for battery status.

  1. Fully charge battery: Connect to AC power until display shows 100%.
  2. Configure settings: Press and hold SETTINGS button to access brightness, auto-off timer.
  3. Test outputs: Connect a small device to verify proper operation.
  4. Enable flashlight: Press flashlight button to activate emergency light.

CAUTION! First charge may take 6-8 hours. Use only provided or recommended accessories.

Specifications

Controls and Settings

Access settings via SETTINGS button. Front Panel: POWER, flashlight, LCD display.

Buttons: POWER (on/off), Flashlight (press for light, hold for SOS), SETTINGS (press for menu).

LCD Display: Shows battery percentage, input power, output power, estimated runtime. Settings Menu: Brightness (high/medium/low), Auto-off timer (1/2/4/8 hours/off), Buzzer (on/off), Temperature display (°F/°C). Charging: Select input source (AC/solar/car).

Connecting Devices

AC Devices: Plug into AC outlet (max 100W). USB: Connect phones, tablets, cameras. DC: Connect car appliances, portable fridge.

  1. Turn on power station before connecting devices.
  2. Match device power requirements to appropriate port.
  3. Monitor LCD for output power and battery level.

Tip: Do not exceed total 100W output across all ports simultaneously.

Charging & Power Management

Supports AC wall charging, solar charging, and car charging.

  1. AC Charging: Connect included adapter to AC input and wall outlet.
  2. Solar Charging: Connect compatible solar panel to solar input port.
  3. Car Charging: Use 12V car charger cable while driving.
  4. Battery Care: Avoid complete discharge; recharge when below 20%.
  5. Power Saving: Enable auto-off timer to conserve battery.
  6. Simultaneous Use: Charge station while powering devices (pass-through charging).

WARNING! Use only recommended solar panels. Do not charge in extreme temperatures.

Safety Features

Overload Protection: Automatically shuts off if exceeding rated power. Short Circuit Protection: Cuts output during short circuit. Temperature Control: Reduces power if overheating. Low Voltage Protection: Shuts down when battery below 10% to prevent damage.

Care & Maintenance

Store in cool, dry place. Clean with dry cloth; do not use liquids.

CAUTION! Do not disassemble. Avoid dropping or impacting. Recharge every 3 months if storing long-term.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits. UL Certified: Meets safety standards for portable power stations. Copyright © 2025 Atempower; trademarks of Atempower Technologies. For support, visit www.atempower.com or contact 1-800-555-ATEM.

Troubleshooting

SymptomPossible CauseCorrective Action
Unit not powering onBattery depletedConnect to AC power for charging; check power button.
No output from portsOverload protection triggeredDisconnect devices, wait 30 seconds, restart unit.
Slow chargingLow input powerEnsure proper power source; use recommended charger.
LCD display blankSleep mode or faultPress any button; if persists, reset unit.
OverheatingHigh ambient temperature or overloadMove to cooler location; reduce connected load.

Reset: Press and hold POWER + SETTINGS for 10 seconds.

Service: 1-800-555-ATEM; www.atempower.com/support