Aquapro AP960SP Instructions Manual

The Aquapro AP960SP is a high-performance submersible water pump designed for residential and light commercial use. It features a durable stainless steel construction, thermal overload protection, a 1.0 HP motor, 960 gallons per hour maximum flow rate, 25-foot maximum head height, 10-foot power cord, and a removable filter basket. Suitable for pond drainage, pool transfer, basement dewatering, and irrigation. Below are key sections for safety, features, installation, operation, maintenance, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Operation 6. Connecting Hoses 7. Maintenance Procedures 8. Safety Features 9. Care & Storage 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Stainless steel pump body, Thermal overload protector, Removable filter basket, 1.0 HP induction motor, Handle, Power cord, Discharge outlet.

FeatureDescription
Motor Power1.0 Horsepower, 120V AC, 60Hz
Maximum Flow Rate960 gallons per hour (GPH)
Maximum Head Height25 feet
ConstructionStainless steel housing, corrosion-resistant
Thermal ProtectionAutomatic shut-off to prevent motor burnout
Filter BasketRemovable for easy cleaning of debris
Discharge OutletStandard 1.25-inch NPT female thread
Power Cord10-foot, 3-prong grounded plug
HandleIntegrated for easy transport
Float Switch CompatibleOptional for automatic operation

Installation

Unpack and inspect contents. Ensure all parts are present and undamaged.

  1. Select location: Place pump on a flat, stable surface near water source.
  2. Connect discharge hose: Attach standard 1.25-inch hose to discharge outlet; secure with hose clamp.
  3. Position pump: Submerge pump completely in water; ensure filter basket is clear of obstructions.
  4. Connect to power: Plug 3-prong cord into grounded GFCI outlet.

WARNING! Never operate pump dry. Always fully submerge before powering on. Ensure electrical connections are dry.

First-Time Setup

Prepare pump for initial use.

  1. Inspect filter basket: Remove and clean any packaging debris.
  2. Test submersion: Place pump in a bucket of water to ensure it is fully submerged.
  3. Power on: Plug into outlet; pump should start automatically if no float switch is connected.
  4. Check flow: Verify water is discharging properly from hose.
  5. Adjust placement: Ensure pump intake is not resting directly on muddy or sandy bottom.

CAUTION! Always lift pump by the handle; do not pull by the power cord. Keep cord away from sharp edges.

Specifications

Controls and Operation

Manual operation: Plug in to start, unplug to stop. For automatic operation, connect optional float switch to designated port.

Operation Modes: Manual (direct plug-in), Automatic (with float switch).

Indicator: Thermal protector will shut off motor if overheated; allow to cool for 15 minutes before restarting.

Performance Tips: For maximum flow, keep hose as short and straight as possible. Regularly clean filter basket. Do not pump water exceeding 95°F (35°C).

Connecting Hoses

Use standard 1.25-inch inner diameter discharge hose.

  1. Ensure pump is unplugged and dry.
  2. Slide hose clamp onto hose.
  3. Push hose firmly onto discharge outlet.
  4. Tighten hose clamp securely with screwdriver.
  5. Route hose to desired drainage area, avoiding kinks.

Tip: For threaded connections, use Teflon tape on male threads to prevent leaks.

Maintenance Procedures

Regular maintenance ensures long pump life.

  1. Monthly: Unplug pump, remove from water, clean filter basket of debris.
  2. Quarterly: Inspect power cord and plug for damage.
  3. Annually: Check impeller for obstructions; lubricate O-ring with silicone grease.
  4. Storage: Clean thoroughly, dry completely, store in a dry location.

WARNING! Always disconnect power before performing any maintenance. Do not disassemble motor housing.

Safety Features

Thermal Overload Protection: Automatically cuts power if motor overheats; resets when cooled. Grounded Plug: 3-prong plug for safety. Submersible Design: Rated IPX8 for continuous underwater operation.

Care & Storage

After use, clean pump with fresh water. Dry completely before storage. Store in a cool, dry place away from direct sunlight.

CAUTION! Never use harsh chemicals or high-pressure water to clean. Do not store with water inside the pump housing.

Regulatory Information

This device complies with Part 15 of the FCC Rules. Operation is subject to the condition that this device does not cause harmful interference. ETL listed to UL Standard 1081. Copyright © Aquapro. For support, visit www.aquapro.com or contact 1-800-555-0199.

Troubleshooting

SymptomPossible CauseCorrective Action
Pump does not startNo power, thermal trip, dry runCheck outlet and cord; let cool 15 min; ensure full submersion.
Low flow or pressureClogged filter, long/high hose, air leakClean basket; shorten hose/check head height; check hose connections.
Pump runs then stopsThermal overload activatedAllow to cool; check for blockage causing overload.
Unusual noise/vibrationDebris in impeller, worn bearingUnplug, inspect and clean impeller area; contact service if bearing issue.
Water leaking from housingDamaged seal or crackUnplug immediately. Do not use. Contact customer service.

Reset: Thermal protector resets automatically after cooling.

Service: 1-800-555-0199; www.aquapro.com