The Amp Lighting ASAC-SPAN1-S-BK is a single-head, adjustable-span, low-voltage landscape lighting fixture designed for outdoor accent and path lighting. Constructed with a durable black powder-coated finish, it features a sealed optical assembly, adjustable beam spread, and is compatible with 12V AC/DC LED or halogen lamps. Below are key sections for safety, features, installation, wiring, aiming, maintenance, and troubleshooting.
Key components: Adjustable-span spike mount, Die-cast aluminum housing, Polycarbonate lens, Sealed optical chamber, Integrated wire guard, Adjustable locking collar for beam direction.
| Feature | Description |
|---|---|
| Housing Material | Die-cast aluminum with black powder-coat finish |
| Lens Material | Impact-resistant polycarbonate |
| Mounting | Adjustable-span ground spike (included) |
| Voltage | 12V AC/DC (low-voltage) |
| Lamp Compatibility | MR11/MR16 LED or Halogen (max 20W) |
| Beam Adjustment | 360° horizontal, 90° vertical |
| IP Rating | IP67 (Dust tight & protected against immersion) |
| Wire Connection | Integrated waterproof wire nuts |
| Warranty | 5-year limited warranty |
Read all instructions before installation. Ensure power is OFF at transformer during installation.
WARNING! Risk of electric shock. Disconnect power before servicing. Do not exceed maximum wattage rating.
Required tools: Phillips screwdriver, Wire strippers, Pliers, Tape measure, Mallet (for spike).
CAUTION! Use only outdoor-rated, direct-burial low-voltage cable for underground runs.
Locate fixture in desired area, ensuring cable can reach transformer.
Tip: For hard soil, pre-drill a pilot hole for the spike.
Connect fixture to low-voltage landscape cable.
WARNING! Polarity matters for LED lamps. Ensure correct (+/-) connections.
Adjust beam after installation and power-on.
Note: Allow lamp to cool before handling optical assembly.
Replace lamp when output diminishes or fails.
CAUTION! Use only specified lamp types. Do not exceed 20W.
Periodic maintenance ensures optimal performance and longevity.
Tip: Clean fixtures in spring and fall for best light output.
This product complies with UL Standard 1838 for Low Voltage Landscape Lighting Systems. It is intended for outdoor residential use. Installation must conform to National Electrical Code (NEC) Article 411 and all applicable local codes. Amp Lighting is a registered trademark. For technical support or warranty service, contact Amp Lighting at 1-800-555-1234 or visit www.amplighting.com.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| Fixture does not light | Power off, loose connection, bad lamp | Check transformer power; inspect wire connections; replace lamp. |
| Dim light | Undersized transformer, voltage drop, old lamp | Ensure transformer capacity; check for long wire runs; replace lamp. |
| Flickering light | Loose connection, failing transformer | Secure all wire connections; test transformer output. |
| Water inside fixture | Damaged seal, lens not sealed properly | Inspect and clean seal; ensure lens is tightly installed. |
| Fixture unstable | Loose spike, soft soil | Firmly tamp soil around spike; use stabilizing kit (optional). |
Reset: For electronic transformers, cycle power OFF/ON.
Service: 1-800-555-1234; www.amplighting.com