The Agro Electro 0146-2 is a versatile agricultural electrical device designed for farm automation and power management. It features robust construction for outdoor use, multiple power input/output options, integrated safety protections, programmable timers, remote control capability, and compatibility with standard agricultural equipment. Powered by 110-240V AC, 50/60Hz. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.
Key components: Weather-resistant enclosure, Control Panel, Power Input terminals, Output sockets, Remote Sensor port, LCD Display, Emergency Stop button.
| Feature | Description |
|---|---|
| Power Input terminals | For main AC power connection (110-240V) |
| Output sockets | Multiple protected outlets for agricultural equipment |
| Remote Sensor port | For connecting soil moisture or temperature sensors |
| LCD Display | Shows status, timer settings, and error codes |
| Emergency Stop | Immediately cuts power to all outputs |
| Programmable Timer | 4 independent channels with daily/weekly schedules |
| Overload Protection | Automatic shutdown on excessive current draw |
| Water Resistance | IP65 rated for dust and water protection |
| Remote Control | Wireless remote for basic operations up to 100m |
| Battery Backup | Maintains timer settings during power outages |
Unpack and inspect contents. Mount on stable vertical surface.
WARNING! Installation must be performed by qualified electrician. Ensure all connections are secure and waterproof.
Power on device; follow display prompts.
CAUTION! Keep device away from direct water spray despite IP65 rating. Ensure proper grounding.
Access menu via MENU button. Front Panel: POWER button, EMERGENCY STOP, MENU, UP/DOWN arrows, ENTER, MANUAL OVERRIDE buttons for each channel.
Remote: POWER ON/OFF, CHANNEL SELECT (1-4), MANUAL ON/OFF, TIMER ENABLE/DISABLE, LOCK.
Menu Settings: Date/Time, Timer Programs (start/stop times, days of week), Sensor Settings (calibration, thresholds), System Settings (language, display contrast, buzzer volume), Security (PIN code default 0000). Output Configuration: Assign sockets to channels, set current limits, enable/disable individual outputs.
Power Input: L, N, G terminals. Outputs: 4 protected sockets. Sensors: Remote sensor port (RJ11).
Tip: Label each output socket with connected equipment for easy identification.
Supports Manual, Timer, and Sensor-Automatic modes.
WARNING! Do not exceed maximum current ratings. Monitor equipment during initial operation.
Overload Protection: Automatic shutdown if current exceeds limits. Emergency Stop: Immediate power cutoff. Ground Fault Detection: Monitors for leakage current. Surge Protection: Built-in protection against voltage spikes. Thermal Protection: Shuts down if internal temperature exceeds safe limits.
Disconnect power before maintenance. Clean exterior with damp cloth only. Check terminals annually for corrosion. Test safety features every 6 months.
CAUTION! Do not open enclosure unless qualified. Keep ventilation openings clear of debris.
CE Certified: Complies with European safety standards. RoHS Compliant: Free of hazardous substances. FCC Part 15: Class B digital device. Copyright © 2025 Agro Electro; all rights reserved. For technical support, visit www.agroelectro.com/support or contact +1-800-555-0146.
| Symptom | Possible Cause | Corrective Action |
|---|---|---|
| No power to unit | Main power/connections | Check main power supply; verify input connections; reset circuit breaker. |
| Output not working | Timer settings/overload | Check timer programming; verify manual operation; check for overload condition. |
| Display blank | Power/backlight | Check power connection; adjust display contrast in settings. |
| Remote not working | Batteries/range/obstacles | Replace batteries; reduce distance; remove obstacles; re-pair remote. |
| False overload trips | Equipment fault/wiring | Disconnect equipment one by one to identify fault; check wiring connections. |
| Sensor not reading | Connection/calibration | Check sensor connection; recalibrate sensor; replace if damaged. |
Reset: Menu > System > Factory Reset (requires PIN code).
Service: +1-800-555-0146; www.agroelectro.com/support