Acopower PE-LTK-3x40W Product Introduction

The Acopower PE-LTK-3x40W is a high-performance LED tube light kit designed for energy-efficient illumination in commercial and industrial settings. This kit includes three 40W LED tubes with a high lumen output, compatible ballast bypass or direct wire installation, a color temperature of 5000K (daylight), high CRI for accurate color rendering, and a long lifespan of up to 50,000 hours. It is suitable for retrofitting existing fluorescent fixtures or new installations. Below are key sections for features, installation, specifications, operation, and safety information.

1. Features at a Glance 2. Installation Guide 3. First-Time Setup 4. Specifications 5. Controls and Operation 6. Wiring Configuration 7. Maintenance & Care 8. Safety Information 9. Regulatory Compliance 10. Troubleshooting

Features at a Glance

Key components: Three 40W LED tubes, wiring connectors, mounting brackets, and installation manual.

FeatureDescription
High Lumen OutputDelivers up to 4500 lumens per tube for bright, even illumination
Energy EfficientConsumes up to 50% less energy compared to traditional fluorescent tubes
Long LifespanRated for up to 50,000 hours of operation
Color Temperature5000K daylight white for clear, natural lighting
High CRI80+ Color Rendering Index for accurate color representation
Installation FlexibilityCompatible with ballast bypass or direct wire setups
Durable ConstructionMade with polycarbonate diffuser and aluminum heat sink
Wide Voltage RangeOperates on 100-277V AC, 50/60Hz
Instant OnNo warm-up time; full brightness immediately
Dimmable OptionCompatible with compatible dimmers (if specified)

Installation Guide

Unpack and inspect all components. Ensure power is turned off at the circuit breaker before installation.

  1. Remove existing fluorescent tubes and ballast (for ballast bypass installation).
  2. Install mounting brackets securely to the fixture or ceiling.
  3. Connect LED tubes using provided wiring connectors following wiring diagram.
  4. Secure tubes into brackets and ensure all connections are tight.
  5. Restore power and test operation.

WARNING! Installation should be performed by a qualified electrician. Ensure all power is disconnected before beginning work to avoid electrical shock.

First-Time Setup

After installation, verify proper operation and adjust as needed.

  1. Power on the circuit and check all three tubes illuminate.
  2. Verify even light distribution and absence of flickering.
  3. If dimmable, test dimmer functionality with compatible dimmer switch.
  4. Adjust mounting angle if necessary for optimal light coverage.

CAUTION! Do not touch LED tubes with bare hands during installation; use gloves to prevent oil residue affecting performance.

Specifications

Controls and Operation

Operation is via standard wall switch or compatible dimmer. No dedicated remote control included.

Basic Operation: Turn power on/off using wall switch. For dimmable models, adjust light level using compatible dimmer switch.

Maintenance Mode: No user-serviceable parts inside. For cleaning, power off and follow care instructions.

Wiring Configuration

Two installation methods: Ballast Bypass (recommended) or Direct Wire with existing ballast (if compatible).

  1. Ballast Bypass: Remove existing ballast, wire AC power directly to LED tube sockets.
  2. Direct Wire (if compatible): Use with specified electronic ballasts; follow manufacturer wiring diagram.

Tip: Always refer to the included wiring diagram specific to your fixture type. Use wire nuts and electrical tape for secure connections.

Maintenance & Care

Regular maintenance ensures optimal performance and longevity.

  1. Turn off power and allow tubes to cool before cleaning.
  2. Clean tubes and fixture with a soft, dry cloth. For stubborn dirt, use a damp cloth with mild detergent, then dry thoroughly.
  3. Inspect wiring connections annually for looseness or corrosion.
  4. Replace tubes if noticeable dimming or flickering occurs after prolonged use.

CAUTION! Do not use abrasive cleaners or solvents. Never spray liquids directly onto tubes or electrical components.

Safety Information

Read all instructions before installation and operation.

Regulatory Compliance

This product complies with relevant safety and performance standards.

Copyright © 2025 Acopower. All trademarks are property of their respective owners. For support, visit www.acopower.com or contact 1-800-555-ACOP.

Troubleshooting

SymptomPossible CauseCorrective Action
Tube does not lightPower off / Loose connectionCheck circuit breaker; ensure power is on. Verify all wiring connections are secure.
Flickering lightIncompatible ballast / Poor connectionFor ballast bypass, ensure ballast is removed. Tighten all wire connections.
Dim outputEnd of life / Voltage issueTubes may need replacement after 50,000 hours. Check input voltage is within 100-277V AC.
Buzzing soundBallast issue / Loose partsIn ballast bypass, ensure ballast is disconnected. Tighten mounting hardware.
Partial lightingDefective tube / Wiring errorSwap tubes to identify faulty one; replace if necessary. Review wiring diagram.

Reset: Turn power off for 30 seconds, then restore power.

Service: For technical support, contact 1-800-555-ACOP or visit www.acopower.com/support.

Acopower PE-LTK-3x40W Product Introduction © - All Rights Reserved 2025