Acopower 3x40W Manual

The Acopower 3x40W is a versatile lighting system featuring three 40-watt LED panels, designed for professional photography, videography, and studio applications. It offers adjustable color temperature (3200K-5600K), high CRI (≥95), dimmable brightness control, multiple power options (AC/DC), and includes accessories such as softboxes, stands, and remote control. Below are key sections for safety, features, installation, setup, operation, and troubleshooting.

1. Features at a Glance 2. Installation 3. First-Time Setup 4. Specifications 5. Controls and Settings 6. Connecting Devices 7. Operating Modes 8. Safety Features 9. Care & Maintenance 10. Regulatory Information 11. Troubleshooting

Features at a Glance

Key components: Three LED light panels, Remote Control, Power Adapter, Mounting Stands, Softbox Diffusers, Carrying Case.

FeatureDescription
LED PanelsThree 40W high-output LED panels with adjustable brackets
Color TemperatureAdjustable from 3200K (warm) to 5600K (daylight)
CRI Rating≥95 for accurate color reproduction
Dimmable Control0-100% brightness adjustment
Power InputAC 100-240V, 50/60Hz; DC 12-24V compatible
Remote ControlWireless control for all three panels
Mounting OptionsStandard 1/4"-20 and 5/8" mounting threads
Softbox DiffusersIncluded for each panel to soften light output
Stand IncludedThree adjustable light stands (max height 2.1m)
Carrying CasePortable case for transport and storage

Installation

Unpack and inspect all contents. Assemble on stable surface.

  1. Assemble stands: Extend each stand to desired height and lock securely.
  2. Attach LED panels: Mount each panel to stand using mounting bracket.
  3. Attach softboxes: Secure softbox diffusers over each LED panel.
  4. Connect power: Plug AC adapter into power outlet and connect to panels.
  5. Remote setup: Insert batteries into remote control.

WARNING! Ensure stands are fully extended and locked to prevent tipping. Do not exceed maximum load capacity.

First-Time Setup

Power on system; configure initial settings.

  1. Power connection: Connect AC adapter to power source and LED panels.
  2. Remote pairing: Press SYNC button on remote and main panel for pairing.
  3. Color temperature: Adjust to desired setting (default 5600K).
  4. Brightness level: Set initial brightness to 50% for testing.
  5. Test all panels: Ensure all three panels respond to remote control.

CAUTION! Allow LED panels to cool before adjusting or moving. Do not touch LED surface during operation.

Specifications

Controls and Settings

Access controls via front panel buttons or remote control. Front Panel: POWER, MODE, BRIGHTNESS+, BRIGHTNESS-, COLOR TEMP.

Remote: POWER, PANEL SELECT (1,2,3,ALL), BRIGHTNESS +/-, COLOR +/-, SYNC, MEMORY (M1-M3).

Color Temperature: Adjust from 3200K (warm) to 5600K (daylight) in 100K increments. Brightness: Adjust from 0% (off) to 100% (maximum). Memory Settings: Save up to 3 custom settings for quick recall. Sync Mode: Synchronize all three panels to same settings.

Connecting Devices

Power: AC adapter or DC input. Remote: Infrared wireless control.

  1. Turn off all panels before connecting power.
  2. Connect AC adapter to wall outlet first, then to panels.
  3. For DC operation, ensure voltage matches (12-24V).
  4. Point remote directly at panel IR sensor (within 8 meters).

Tip: Use included cable management clips to organize power cables.

Operating Modes

Supports individual panel control or synchronized operation.

  1. Individual control: Select panel 1, 2, or 3 on remote to adjust separately.
  2. Group control: Select ALL to control all three panels simultaneously.
  3. Memory recall: Press M1, M2, or M3 to recall saved settings.
  4. Color matching: Use COLOR +/- to match existing lighting conditions.
  5. Dimming: Adjust brightness for desired lighting effect.
  6. Strobe mode: Not available - continuous lighting only.
  7. Battery operation: Connect to compatible DC power source for portable use.
  8. Overheat protection: Automatic dimming if temperature exceeds safe limits.

WARNING! Do not operate in wet conditions. Allow ventilation around panels.

Safety Features

Overheat Protection: Automatic brightness reduction at high temperatures. Fuse Protection: Built-in fuse for electrical safety. Locking Stands: Secure locking mechanisms on all stands.

Care & Maintenance

Unplug before cleaning. Use soft, dry cloth for LED surfaces. Clean softboxes with mild soap and water if needed.

CAUTION! Do not use chemical cleaners on LED panels. Store in dry location when not in use.

Regulatory Information

FCC Part 15: Class B digital device; complies with interference limits. CE, RoHS compliant. Copyright © 2023 Acopower; all rights reserved. For support, visit www.acopower.com or contact 1-800-555-ACOP (2267).

Troubleshooting

SymptomPossible CauseCorrective Action
Panel not turning onPower connectionCheck power adapter connection; ensure outlet has power.
Remote not workingBatteries/obstaclesReplace batteries; ensure line of sight to IR sensor.
Uneven brightnessSettings/diffuserCheck brightness settings; ensure diffuser properly attached.
OverheatingVentilationAllow space around panels for airflow; reduce brightness.
Color inconsistencySettings/temperatureReset to factory settings; ensure all panels same temperature.
Stand instabilityLocking mechanismEnsure all locks engaged; adjust on level surface.

Reset: Hold POWER + MODE for 5 seconds to factory reset.

Service: 1-800-555-ACOP (2267); www.acopower.com/support

Acopower 3x40W Manual © - All Rights Reserved 2025